      Healthcare Personnel Attire and Devices as Fomites: A Systematic Review

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          BACKGROUND

          Transmission of pathogens within the hospital environment remains a hazard for hospitalized patients. Healthcare personnel clothing and devices carried by them may harbor pathogens and contribute to the risk of pathogen transmission.

          OBJECTIVE

          To examine bacterial contamination of healthcare personnel attire and commonly used devices.

          METHODS

          Systematic review.

          RESULTS

          Of 1,175 studies screened, 72 individual studies assessed contamination of a variety of items, including white coats, neckties, stethoscopes, and mobile electronic devices, with varied pathogens including Staphylococcus aureus,including methicillin-resistant S. aureus, gram-negative rods, and enterococci. Contamination rates varied significantly across studies and by device but in general ranged from 0 to 32% for methicillin-resistant S. aureusand gram-negative rods. Enterococcuswas a less common contaminant. Few studies explicitly evaluated for the presence of Clostridium difficile.Sampling and microbiologic techniques varied significantly across studies. Four studies evaluated for possible connection between healthcare personnel contaminants and clinical isolates with no unequivocally direct link identified.

          CONCLUSIONS

          Further studies to explore the relationship between healthcare personnel attire and devices and clinical infection are needed.

          Infect Control Hosp Epidemiol2016;1–7

          Related collections

          Most cited references76

          • Record: found
          • Abstract: found
          • Article: not found

          Review of mobile communication devices as potential reservoirs of nosocomial pathogens.

          Innovation in mobile communication technology has provided novel approaches to the delivery of healthcare and improvements in the speed and quality of routine medical communication. Bacterial contamination of mobile communication devices (MCDs) could be an important issue affecting the implementation of effective infection control measures and might have an impact on efforts to reduce cross-contamination. This review examines recent studies reporting bacterial contamination of MCDs, most demonstrating that 9-25% of MCDs are contaminated with pathogenic bacteria. We examine previously investigated risk factors for MCD contamination in addition to work on surface decontamination of the device. Recommendations to reduce contamination risks include staff education, strict hand hygiene measures, guidelines on device cleaning and consideration of the restrictions regarding use of mobile phone technology in certain high risk areas, for example, operating theatres, intensive care units and burns units. Further work is required to evaluate the benefit of such interventions on MCD contamination and to determine whether a link exists between contamination and subsequent patient infection.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Are we aware how contaminated our mobile phones with nosocomial pathogens?

            Background The objective of this study was to determine the contamination rate of the healthcare workers' (HCWs') mobile phones and hands in operating room and ICU. Microorganisms from HCWs' hands could be transferred to the surfaces of the mobile phones during their use. Methods 200 HCWs were screened; samples from the hands of 200 participants and 200 mobile phones were cultured. Results In total, 94.5% of phones demonstrated evidence of bacterial contamination with different types of bacteria. The gram negative strains were isolated from mobile phones of 31.3% and the ceftazidime resistant strains from the hands were 39.5%. S. aureus strains isolated from mobile phones of 52% and those strains isolated from hands of 37.7% were methicillin resistant. Distributions of the isolated microorganisms from mobile phones were similar to hands isolates. Some mobile phones were contaminated with nosocomial important pathogens. Conclusion These results showed that HCWs' hands and their mobile phones were contaminated with various types of microorganisms. Mobile phones used by HCWs in daily practice may be a source of nosocomial infections in hospitals.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Bacterial contamination of health care workers' white coats.

              Patient-to-patient transmission of nosocomial pathogens has been linked to transient colonization of health care workers, and studies have suggested that contamination of health care workers' clothing, including white coats, may be a vector for this transmission. We performed a cross-sectional study involving attendees of medical and surgical grand rounds at a large teaching hospital to investigate the prevalence of contamination of white coats with important nosocomial pathogens, such as methicillin-sensitive Stapylococcus aureus, methicillin-resistant S aureus (MRSA), and vancomycin-resistant enterococci (VRE). Each participant completed a brief survey and cultured his or her white coat using a moistened culture swab on lapels, pockets, and cuffs. Among the 149 grand rounds attendees' white coats, 34 (23%) were contaminated with S aureus, of which 6 (18%) were MRSA. None of the coats was contaminated with VRE. S aureus contamination was more prevalent in residents, those working in inpatient settings, and those who saw an inpatient that day. This study suggests that a large proportion of health care workers' white coats may be contaminated with S aureus, including MRSA. White coats may be an important vector for patient-to-patient transmission of S aureus.
                Bookmark

                Author and article information

                Journal
                Infection Control & Hospital Epidemiology
                Infect. Control Hosp. Epidemiol.
                Cambridge University Press (CUP)
                0899-823X
                1559-6834
                November 2016
                September 09 2016
                November 2016
                : 37
                : 11
                : 1367-1373
                Article
                10.1017/ice.2016.192
                27609491
                c8afa7e5-7674-40c5-a047-59fdc8f057fd
                © 2016

                https://www.cambridge.org/core/terms

                History

                Comments

                Comment on this article