      CLSI Methods Development and Standardization Working Group Best Practices for Evaluation of Antimicrobial Susceptibility Tests

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          ABSTRACT

          Effective evaluations of antimicrobial susceptibility tests (ASTs) require robust study design. The Clinical and Laboratory Standards Institute (CLSI) Subcommittee on Antimicrobial Susceptibility Testing has recognized that many published studies reporting the performance of commercial ASTs (cASTs) suffer from major design and/or analysis flaws, rendering the results difficult or impossible to interpret. This minireview outlines the current consensus of the Methods Development and Standardization Working Group of the CLSI Subcommittee on Antimicrobial Susceptibility Testing regarding best practices for systematic evaluation of the performance of an AST, including the analysis and presentation of essential data intended for publication.

          Related collections

          Most cited references12

          • Record: found
          • Abstract: found
          • Article: not found

          Colistin MIC variability by method for contemporary clinical isolates of multidrug-resistant Gram-negative bacilli.

          In vitro evaluation of colistin susceptibility is fraught with complications, due in part to the inherent cationic properties of colistin. In addition, no reference method has been defined against which to compare the results of colistin susceptibility testing. This study systematically evaluated the available methods for colistin MIC testing in two phases. In phase I, colistin MICs were determined in 107 fresh clinical isolates of multidrug-resistant (MDR) Gram-negative bacilli (GNB) by broth microdilution with polysorbate 80 (BMD-T), broth macrodilution (TDS), and the Etest. In phase II, 50 of these isolates, 10 of which were colistin resistant, were tested in parallel using BMD-T, TDS, agar dilution, broth microdilution without polysorbate 80 (BMD), and the TREK Gram-negative extra MIC format (GNXF) Sensititre. The Etest was also performed on these 50 isolates using Mueller-Hinton agar (MHA) from three different manufacturers. Colistin MIC results obtained from the five methods were compared to the MIC results obtained using BMD-T, the method that enables the highest nominal concentration of colistin in the test medium. Essential agreement ranged from 34% (BMD) to 83% (TDS), whereas categorical agreement was >90% for all methods except for BMD, which was 88%. Very major errors (VMEs) (i.e., false susceptibility) for the Etest were found in 47 to 53% of the resistant isolates, depending on the manufacturer of the MHA that was used. In contrast, VMEs were found for 10% (n = 1) of the resistant isolates by BMD and 0% of the isolates by the TDS, agar dilution, and Sensititre methods. Based on these data, we urge clinical laboratories to be aware of the variable results that can occur when using different methods for colistin MIC testing and, in particular, to use caution with the Etest.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Performance of Vitek 2 for Antimicrobial Susceptibility Testing of Enterobacteriaceae with Vitek 2 (2009 FDA) and 2014 CLSI Breakpoints

            Vitek 2 (bioMérieux Inc., Durham, NC) is a widely used commercial antimicrobial susceptibility test system. We compared the MIC results obtained using the Vitek 2 AST-GN69 and AST-XN06 cards to those obtained by CLSI broth microdilution (BMD) for 255 isolates of Enterobacteriaceae , including 25 isolates of carbapenem-resistant Enterobacteriaceae . In total, 25 antimicrobial agents were examined. For 10 agents, the MIC data were evaluated using two sets of breakpoints: (i) the Vitek 2 breakpoints, which utilized the 2009 FDA breakpoints at the time of the study and are equivalent to the 2009 CLSI M100-S19 breakpoints, and (ii) the 2014 CLSI M100-S24 breakpoints. There was an overall 98.7% essential agreement (EA). The categorical agreement was 95.5% (CA) using the Vitek 2 breakpoints and 95.7% using the CLSI breakpoints. There was 1 very major error (VME) (0.05%) observed using the Vitek 2 breakpoints (cefazolin) and 8 VMEs (0.5%) using the CLSI breakpoints (2 each for aztreonam, cefepime, and ceftriaxone, and 1 for cefazolin and ceftazidime). Fifteen major errors (MEs) (0.4%) were noted using the Vitek 2 breakpoints and 8 (0.5%) using the CLSI breakpoints. Overall, the Vitek 2 performance was comparable to that of BMD for testing a limited number of Enterobacteriaceae commonly isolated by clinical laboratories. Ongoing studies are warranted to assess performance in isolates with emerging resistance.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Performance of Vitek 2 for Antimicrobial Susceptibility Testing of Acinetobacter baumannii, Pseudomonas aeruginosa, and Stenotrophomonas maltophilia with Vitek 2 (2009 FDA) and CLSI M100S 26th Edition Breakpoints.

              The performances of Vitek 2 AST-GN69 and AST-XN06 cards were compared to Clinical and Laboratory Standards Institute (CLSI) reference broth microdilution (BMD) for 99 isolates of Pseudomonas aeruginosa, 26 Acinetobacter baumannii isolates, and 11 Stenotrophomonas maltophilia isolates. In total, 15 antimicrobials were evaluated, with 11 for P. aeruginosa, 14 for A. baumannii, and 2 for S. maltophilia Categorical agreement (CA) was assessed using both Vitek 2 breakpoints and 2016 CLSI M100S 26th edition breakpoints. The essential agreement values for P. aeruginosa, A. baumannii, and S. maltophilia were 99.5%, 99.2%, and 100%, respectively. The CA values for P. aeruginosa, A. baumannii, and S. maltophilia were 94.1%, 92.7%, and 95.5%, respectively, by the Vitek 2 breakpoints, and 93.4%, 92.3%, and 95.5%, respectively, by the CLSI breakpoints. Overall, the Vitek 2 performance was comparable to that of BMD using both Vitek 2 breakpoints and 2016 CLSI M100S 26th edition breakpoints. Improved performance was noted for the reformulated piperacillin-tazobactam and imipenem found on the AST-GN69 card, with no very major or major errors noted when using the CLSI breakpoints.
                Bookmark

                Author and article information

                Journal
                Journal of Clinical Microbiology
                J Clin Microbiol
                American Society for Microbiology
                0095-1137
                1098-660X
                April 2018
                March 26 2018
                January 24 2018
                : 56
                : 4
                Article
                10.1128/JCM.01934-17
                5869819
                29367292
                502fb920-a739-4663-b998-3cb983d5de4d
                © 2018
                History

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content88

                Cited by193

                Most referenced authors115