      FIL SSF intraocular lens opacification after pars plana vitrectomy with gas tamponade for traumatic lens luxation and retinal detachment: a case report and literature review

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          To report a case of sutureless scleral-fixated hydrophilic intraocular lens (FIL SSF IOL, Soleko, Italy) opacification following pars plana vitrectomy surgery using sulfur hexafluoride (SF6) for traumatic lens luxation associated with retinal detachment.

          Case presentation

          A 77-year-old woman was referred to our emergency department after blunt trauma in her right eye. At the ophthalmic evaluation, visual acuity was hand movement, biomicroscopy showed pseudoexfoliation syndrome and a traumatic lens luxation in the vitreous chamber. The patient underwent pars plana vitrectomy, subluxated cataract explantation, and FIL SSF IOL implant. During surgery, an inferior retinal detachment was encountered, requiring 20% SF6 gas tamponade. No adverse events were encountered. One month postoperatively, visual acuity (BCVA) improved to 0,3 logMAR. At the 3-month follow-up, the patient presented with BCVA of 0,5 logMAR, and biomicroscopy showed a minimal IOL opacification. Six months postoperatively, BCVA decreased to 1.0 logMAR, and diffuse, IOL opacification was noted at slit lamp examination. The patient refused any other surgical intervention for IOL exchange.

          Conclusions

          Although hydrophilic IOL opacification gas related is known, to the best of our knowledge, this is the first case reported in the literature of FIL SSF IOL opacification after pars plana vitrectomy with gas tamponade for retinal detachment.

          Related collections

          Most cited references23

          • Record: found
          • Abstract: found
          • Article: not found

          Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique.

          To report the clinical outcomes of a new technique for transconjunctival intrascleral fixation of an intraocular lens (IOL).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection.

            To report a new technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (IOL).
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Scleral fixation of intraocular lenses using Gore-Tex suture: clinical outcomes and safety profile.

              To report the short-term safety profile and clinical outcomes of scleral fixation of intraocular lenses (IOLs) using Gore-Tex suture.
                Bookmark

                Author and article information

                Contributors
                iannettadanilo@gmail.com
                Journal
                BMC Ophthalmol
                BMC Ophthalmol
                BMC Ophthalmology
                BioMed Central (London )
                1471-2415
                25 September 2023
                25 September 2023
                2023
                : 23
                : 383
                Affiliations
                [1 ]Ophthalmology Unit, Dipartimento di Scienze Mediche e Chirurgiche, Alma Mater Studiorum University of Bologna, ( https://ror.org/01111rn36) Bologna, Italy
                [2 ]GRID grid.6292.f, ISNI 0000 0004 1757 1758, IRCCS Azienda Ospedaliero-Universitaria di Bologna, ; Via Pelagio Palagi 9 Bologna, Postal code, 40138 Bologna, Italy
                Article
                3126
                10.1186/s12886-023-03126-6
                10519003
                37743488
                fb840b5f-88e0-4d92-a6bc-d71d58453847
                © BioMed Central Ltd., part of Springer Nature 2023

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 28 June 2023
                : 7 September 2023
                Categories
                Case Report
                Custom metadata
                © BioMed Central Ltd., part of Springer Nature 2023

                Ophthalmology & Optometry
                fil ssf intraocular lens,scleral fixation,secondary iol implant iol opacification,pars plana vitrectomy,lens luxation

                Comments

                Comment on this article