14
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Endobronchial ultrasonography using a guide sheath technique for diagnosis of peripheral pulmonary lesions

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Endobronchial ultrasonography using a guide sheath (EBUS-GS) is a novel method used for collecting peripheral pulmonary lesion (PPL) samples. EBUS-GS is performed by introducing a guide sheath-covered miniprobe into the target bronchus and then withdrawing the miniprobe after lesion detection, leaving the guide sheath in situ as a working channel for obtaining lesion samples. EBUS-GS can improve PPL diagnosis rates and be used for obtaining specimens for molecular analysis. In this review, we discuss the clinical applications of EBUS-GS, the factors that affect its diagnostic sensitivity, and potential complications. We also compare EBUS-GS with other available diagnostic techniques and discuss the strengths and limitations of this method.

          Related collections

          Most cited references37

          • Record: found
          • Abstract: found
          • Article: not found

          Ultrathin Bronchoscopy with Multimodal Devices for Peripheral Pulmonary Lesions. A Randomized Trial.

          The combination of an ultrathin bronchoscope, navigational technology, and endobronchial ultrasound (EBUS) seems to combine the best of mutual abilities for evaluating peripheral pulmonary lesions, but ultrathin bronchoscopes that allow the use of EBUS have not been developed so far.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Factors related to diagnostic yield of transbronchial biopsy using endobronchial ultrasonography with a guide sheath in small peripheral pulmonary lesions.

            To evaluate factors predicting the diagnostic yield of transbronchial biopsy (TBB) using endobronchial ultrasonography with a guide sheath (EBUS-GS) in small peripheral pulmonary lesions (PPLs) 15 mm and
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Diagnostic value of endobronchial ultrasonography with a guide sheath for peripheral pulmonary lesions without X-ray fluoroscopy.

              We evaluated the feasibility and efficacy of transbronchial biopsy (TBB) and bronchial brushing by endobronchial ultrasonography (EBUS) with a guide sheath (GS) as a guide for diagnosing peripheral pulmonary lesions (PPLs) without radiographic fluoroscopy. One hundred twenty-one patients with 123 PPLs (mean diameter, 31.0 mm) whose bronchoscopic findings were normal. An EBUS-GS was inserted and advanced to the PPL without fluoroscopy. Once we obtained the EBUS image, the probe was withdrawn and the GS was left in place. TBB and/or bronchial brushing were performed via the GS. When an EBUS image could not be obtained, we changed to the bronchoscopic examination under fluoroscopy. Seventy-six of 123 PPLs (61.8%) were diagnosed by EBUS-GS guidance without fluoroscopy. The diagnostic yield for PPLs > 20 mm in diameter (75.6%) was significantly higher than that for those
                Bookmark

                Author and article information

                Journal
                Endosc Ultrasound
                Endosc Ultrasound
                EUS
                Endoscopic Ultrasound
                Medknow Publications & Media Pvt Ltd (India )
                2303-9027
                2226-7190
                Sep-Oct 2017
                : 6
                : 5
                : 292-299
                Affiliations
                [1]National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
                [1 ]Airforce General Hospital, PLA, Beijing, China
                Author notes
                Address for correspondence Dr. Guiqi Wang, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. E-mail: wangguiqi@ 123456cicams.ac.cn
                Article
                EUS-6-292
                10.4103/eus.eus_48_17
                5664849
                29063872
                d5ffe81f-58ef-4b1e-8b69-5e089a421221
                Copyright: © 2017 Spring Media Publishing Co. Ltd

                This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

                History
                : 26 December 2016
                : 28 June 2017
                Categories
                Review Article

                bronchoscopy,diagnosis,endobronchial ultrasonography,guide sheath,peripheral pulmonary lesions

                Comments

                Comment on this article