      Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement

      , , , ,
      Journal of Biomechanics
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          An experimental investigation was performed to (1) determine the general mechanical behavior and in particular, the post-yield behavior of the cement-bone interface under tensile loading, (2) determine where interface failure occurs, and (3) determine if the mechanical properties of the interface could be related to the density of bone at the interface and/or the amount of cement-bone interdigitation. Seventy-one cement-bone test specimens were machined from human proximal femurs that had been broached and cemented using contemporary cementing techniques. The amount of cement-bone interdigitation was documented and the quantitative computed tomography equivalent mineral density (QCT density) of the bone with cement was measured. Specimens were loaded to failure in tension under displacement control and exhibited linear elastic behavior with some reduction in stiffness until the peak tensile stress was reached (1.28 +/- 0.79 MPa). A substantial amount of strain softening (negative tangent stiffness) with an exponential-type decay was found after the peak stress and continued until there was complete debonding of the specimens (at 0.93 +/- 0.44 mm displacement). Interfacial failure most often occurred at the extent of cement penetration into the bone (56% of specimens) or with small spicules of cement left in the bone (38% of specimens). The results showed that the post-yield tensile behavior contributes substantially to the energy required to cause failure of the cement-bone interface, but the post-yield behavior was not well correlated with the amount of interdigitation or density of bone. Linear regression analysis revealed a moderate (r2 = 0.499, p < 0.0001) positive relationship between the tensile strength of the cement-bone interface and the quantity of bone interdigitated with the cement.

          Related collections

          Author and article information

          Journal
          Journal of Biomechanics
          Journal of Biomechanics
          Elsevier BV
          00219290
          April 1997
          April 1997
          : 30
          : 4
          : 339-346
          Article
          10.1016/S0021-9290(96)00164-9
          9075001
          d2069d3f-2cb3-4123-aa13-cf387fc9ad73
          © 1997

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article