11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      PEEK dental implants: a review of the literature.

      1 ,
      The Journal of oral implantology

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The insertion of dental implants containing titanium can be associated with various complications (eg, hypersensitivity to titanium). The aim of this article is to evaluate whether there are existing studies reporting on PEEK (polyetheretherketone) as an alternative material for dental implants. A systematic literature search of PubMed until December 2010 yielded 3 articles reporting on dental implants made from PEEK. One article analyzed stress distribution in carbon fiber-reinforced PEEK (CFR-PEEK) dental implants by the 3-dimensional finite element method, demonstrating higher stress peaks due to a reduced stiffness compared to titanium. Two articles reported on investigations in mongrel dogs. The first article compared CFR-PEEK to titanium-coated CFR-PEEK implants, which were inserted into the femurs and evaluated after 4 and 8 weeks. The titanium-coated implants showed significantly higher bone-implant contact (BIC) rates. In a second study, implants of pure PEEK were inserted into the mandibles beside implants made from titanium and zirconia and evaluated after 4 months, where PEEK presented the lowest BIC. The existing articles reporting on PEEK dental implants indicate that PEEK could represent a viable alternative material for dental implants. However, further experimental studies on the chemical modulation of PEEK seem to be necessary, mainly to increase the BIC ratio and to minimize the stress distribution to the peri-implant bone.

          Related collections

          Author and article information

          Journal
          J Oral Implantol
          The Journal of oral implantology
          0160-6972
          0160-6972
          Dec 2013
          : 39
          : 6
          Affiliations
          [1 ] 1  Department of Oral and Maxillofacial Surgery, Clinical Navigation and Robotics, Charité-Campus Virchow Clinic, Berlin, Germany.
          Article
          10.1563/AAID-JOI-D-11-00002
          21905892
          cb388e50-a02c-4ca9-846f-e598bf5feb1d
          History

          Comments

          Comment on this article