0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      The effect of different angle kappa on higher-order aberrations after small incision lenticule extraction

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This study aimed to compare higher-order aberrations (HOAs) after small incision lenticule extraction (SMILE) in patients with different angle kappa. This is a retrospective report in which 341 right eyes of 341 patients who were subjected to SMILE, which used coaxially sighted corneal light reflex (CSCLR) as the treatment zone centered, treated by the same experienced surgeon (LHB) for correction of myopia and myopic astigmatism, preoperative and postoperative spherical equivalent (SE), angle kappa, total higher-order aberrations (total HOA), spherical aberration (SA), vertical coma (VC), horizontal coma (HC), oblique trefoil (OT), and horizontal trefoil (HT), were compared. SMILE showed outstanding performance in terms of safety, efficacy, and predictability. In addition, a comparison of preoperative and postoperative HOAs exhibited the difference of total HOA ( P < 0.01), SA ( P < 0.01), VC ( P < 0.01), and HC ( P < 0.01), which was statistically significant; however, for OT and HT with the longer follow-up time, the statistical difference gradually decreased. For stratification of angle kappa into groups based on decantation, angle kappa was divided into three major groups: r < 0.1 mm, 0.1 ≤ r < 0.2 mm, and r ≥ 0.2 mm; the changes of SA ( F = 4.127, P = 0.021) and OT ( F = 3.687, P = 0.031) exhibited significant difference after 1 year of SMILE. We performed a correlation analysis of all preoperative and postoperative parameters, and the results indicated that the preoperative total HOA was negatively correlated with preoperative cylindrical diopter (DC), and postoperative total HOA, SA, and coma were affected by spherical diopter (DS) and SE. Moreover, we also found a significant difference of SA and VC in the early postoperative with preoperative. SA was positively correlated with Y values and r of 1 year after SMILE. All of the analyzed parameters in the three groups, except for the trefoil, gradually increased over time; however, the trefoil could gradually stabilize over time. We also divided angle kappa into four groups by quadrants; the result showed that the effects of higher-order aberrations were markedly different from the various quadrants. Patients with large angle kappa were able to increase VC and SA postoperatively, and higher HOAs were more significant in patients with high myopia. The differences in quadrants exhibited a diversity of HOAs; this could be attributed to the corneal surface reestablishment and the alteration of angle kappa, but the trend was not apparent. Although all patients displayed increased HOAs after SMILE, the potential application of CSCLR as the treatment zone centered still showed excellent safety, efficacy, and predictability.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: found
          • Article: not found

          Small-incision lenticule extraction for moderate to high myopia: Predictability, safety, and patient satisfaction.

          To present initial clinical experience with small-incision lenticule extraction for the treatment of moderate to high myopia. Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. Prospective clinical study. For small-incision lenticule extraction, an intrastromal lenticule was cut with a femtosecond laser and manually extracted without creation of a flap. Patients were treated and followed for 3 months. Only 1 randomly chosen eye of each patient was used in the statistical analyses. The study enrolled 144 patients. The mean preoperative spherical equivalent was -7.18 diopters (D) ± 1.57 (SD). Of eyes with emmetropia as target refraction, 40% had an uncorrected distance visual acuity of 0.1 logMAR or less 1 day after surgery; this increased to 73% at 3 months. The mean corrected distance visual acuity (CDVA) improved significantly from -0.01 (logMAR) preoperatively to -0.03 3 months postoperatively. None of the 127 eyes lost 2 lines or more of CDVA and 6 eyes lost 1 line of CDVA after 3 months. In contrast, 1 eye gained 2 lines and 24 eyes gained 1 line of CDVA. The achieved refraction was a mean of -0.09 ± 0.45 D from the attempted refraction. Of the eyes, 77% were within ±0.50 D and 95% were within ±1.00 D. Ninety-five percent of the patients would recommend the procedure to others. The refractive predictability, safety, and patient satisfaction 3 months after small-incision lenticule extraction were high and comparable to results in previous studies of femtosecond laser-assisted techniques. Drs. Hjortdal and Asp received travel reimbursement from Carl Zeiss Meditec AG, Jena, Germany. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Measurement of angle kappa with synoptophore and Orbscan II in a normal population.

            To obtain normative values of angle kappa in a normal population by synoptophore and Orbscan II and to compare the reliability of these devices. Three hundred consecutive healthy individuals were enrolled in the study. A complete orthoptic and ophthalmologic examination was performed. Synoptophore and Orbscan II corneal topography were used to measure angle kappa. To evaluate the association of the angle kappa and refraction measures, individuals were further classified according to the degree of myopia and hyperopia. The spherical equivalent error measures were grouped into six categories: > or = -3.00 diopters (D); -2.75 to -1.50 D; -1.25 to -0.50 D; +0.50 to +1.25 D; +1.50 to +2.75 D; and > or = +3.00 D. Paired t test and Pearson's correlation test were used for statistical analysis. The mean age of the individuals was 28.74 +/- 1.63 years (range: 20 to 40 years). The angle kappa values obtained by synoptophore and Orbscan II were normally distributed. In the myopic group, angle kappa values decreased significantly towards negative refractive errors. In contrast, a correlation existed between large positive angles and positive refractive errors in the hyperopic group. Angle kappa values obtained by Orbscan II were significantly higher in all groups when compared to synoptophore (P < .0001). A significant correlation was noted between synoptophore and Orbscan II measurements (r = 0.932, P < .0001). A significant correlation exists between positive refractive errors and large positive angle kappa values. Refractive surgeons must take into account angle kappa, especially in hyperopic patients, to avoid complications related to decentration of the ablation zone.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Outcomes of small incision lenticule extraction (SMILE) in low myopia.

              To report the visual and refractive outcomes of small incision lenticule extraction for low myopia using the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany).
                Bookmark

                Author and article information

                Contributors
                oculistlvhongbin@swmu.edu.cn
                Journal
                Lasers Med Sci
                Lasers Med Sci
                Lasers in Medical Science
                Springer London (London )
                0268-8921
                1435-604X
                28 November 2023
                28 November 2023
                2023
                : 38
                : 1
                : 277
                Affiliations
                [1 ]GRID grid.412601.0, ISNI 0000 0004 1760 3828, The First Affiliated Hospital of Jinan University, ; Guangzhou, 510000 Guangdong Province China
                [2 ]The Affiliated Hospital of Southwest Medical University, ( https://ror.org/0014a0n68) Luzhou, 646000 Sichuan Province China
                Author information
                http://orcid.org/0000-0002-5414-593X
                Article
                3934
                10.1007/s10103-023-03934-8
                10682276
                38012462
                c26f71da-f448-4a92-a54c-c64d672cd504
                © The Author(s) 2023

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 20 February 2023
                : 12 November 2023
                Categories
                Original Article
                Custom metadata
                © Springer-Verlag London Ltd., part of Springer Nature 2023

                Medical physics
                angle kappa,higher-order aberrations,small incision lenticule extraction (smile)

                Comments

                Comment on this article