      Functional Knee Brace Alters Predicted Knee Muscle and Joint Forces in People with ACL Reconstruction during Walking

      ,
      Journal of Applied Biomechanics
      Human Kinetics

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references34

          • Record: found
          • Abstract: found
          • Article: not found

          Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog.

          Our study evaluated tendon-to-bone healing in a dog model. Twenty adult mongrel dogs had a transplantation of the long digital extensor tendon into a 4.8-millimeter drill-hole in the proximal tibial metaphysis. Four dogs were killed at each of five time-periods (two, four, eight, twelve, and twenty-six weeks after the transplantation), and the histological and biomechanical characteristics of the tendon-bone interface were evaluated. Serial histological analysis revealed progressive reestablishment of collagen-fiber continuity between the bone and the tendon. A layer of cellular, fibrous tissue was noted between the tendon and the bone, along the length of the bone tunnel; this layer progressively matured and reorganized during the healing process. The collagen fibers that attached the tendon to the bone resembled Sharpey fibers. High-resolution radiographs showed remodeling of the trabecular bone that surrounded the tendon. At the two, four, and eight-week time-periods, all specimens had failed by pull-out of the tendon from the bone tunnel. The strength of the interface was noted to have significantly and progressively increased between the second and the twelfth week after the transplantation. At the twelve and twenty-six-week time-periods, all specimens had failed by pull-out of the tendon from the clamp or by mid-substance rupture of the tendon. The progressive increase in strength was correlated with the degree of bone ingrowth, mineralization, and maturation of the healing tissue, noted histologically.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Direct measurement of resultant forces in the anterior cruciate ligament. An in vitro study performed with a new experimental technique.

            A new technique was used to measure the resultant forces in the anterior cruciate ligament during a series of loading experiments on seventeen fresh-frozen cadaver specimens. The base of the ligament's tibial attachment was mechanically isolated with a coring cutter, and a specially designed load-transducer was fixed to the bone-plug that contained the ligament's tibial insertion so that the resultant forces were directly measured by the load-cell. Although the magnitudes of values for forces varied considerably between specimens for a given test condition, the patterns of loading with respect to direction of loading and the angle of flexion of the knee were remarkably consistent. Passive extension of the knee generated forces in the ligament only during the last 10 degrees of extension; at 5 degrees of hyperextension, the forces ranged from fifty to 240 newtons (mean, 118 newtons). When a 200-newton pull of the quadriceps tendon was applied to extend a knee slowly against tibial resistance, however, the force in the ligament increased at all angles of flexion of the knee. Internal tibial torque always generated greater forces in the ligament than did external tibial torque; higher forces were recorded as the knee was extended. The greatest forces (133 to 370 newtons) were generated when ten newton-meters of internal tibial torque was applied to a hyperextended knee. Fifteen newton-meters of applied varus moment generated forces of ninety-four to 177 newtons at full extension; fifteen newton-meters of applied valgus moment generated a mean force of fifty-six newtons, which remained unchanged with flexion of the knee. The force during straight anterior translation of the tibia was approximately equal to the anterior force applied to the tibia. The application of 925 newtons of tibiofemoral contact force reduced the mean force in the ligament that was generated by 200 newtons of anterior pull on the tibia by 36 per cent at full extension and 46 per cent at 20 degrees of flexion.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Tensile properties of the human femur-anterior cruciate ligament-tibia complex

                Bookmark

                Author and article information

                Journal
                Journal of Applied Biomechanics
                Journal of Applied Biomechanics
                Human Kinetics
                1065-8483
                1543-2688
                November 2001
                November 2001
                : 17
                : 4
                : 297-311
                Article
                10.1123/jab.17.4.297
                8ffa8165-3b6f-47e3-9edb-7c6f04b4e8e6
                © 2001
                History

                Comments

                Comment on this article