      The stuck haemodialysis catheter—a case report of a rare but dreaded complication following kidney transplantation

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Tunnelled cuffed haemodialysis catheters are at increased risk of incarceration or becoming ‘stuck’ via fibrotic adhesion to the central veins when left in situ for prolonged periods of time. Stuck catheters cannot be removed using standard techniques such as bedside dissection of the cuff. Whilst there are several strategies published for the removal of these incarcerated lines, there is no consensus on the best approach. Here we present a challenging case of a stuck haemodialysis catheter in the acute post transplantation period.

          Case Presentation

          A 66-year-old female on haemodialysis presented for kidney transplantation with a tunnelled-cuffed haemodialysis catheter in situ for five years. Following transplantation, removal of the line was unsuccessful despite dissection of the cuff, with traction causing a choking sensation with tracheal movement. Eventually, the line was removed without complications utilising sequential balloon dilatation by interventional radiology and the patient was discharged without complications.

          Conclusions

          This case serves as a timely reminder of the risks of long-term tunnelled haemodialysis catheters and as a caution towards proceeding with kidney transplantation in those with long-term haemodialysis catheters in situ. Greater nephrologist awareness of interventional radiology techniques for this challenging situation will help to avoid more invasive strategies. The risks of a stuck catheter should be included in the discussions about the optimal vascular access and transplantation suitability for a given patient.

          Related collections

          Most cited references12

          • Record: found
          • Abstract: found
          • Article: not found

          KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update

          The National Kidney Foundation's Kidney Disease Outcomes Quality Initiative (KDOQI) has provided evidence-based guidelines for hemodialysis vascular access since 1996. Since the last update in 2006, there has been a great accumulation of new evidence and sophistication in the guidelines process. The 2019 update to the KDOQI Clinical Practice Guideline for Vascular Access is a comprehensive document intended to assist multidisciplinary practitioners care for chronic kidney disease patients and their vascular access. New topics include the end-stage kidney disease "Life-Plan" and related concepts, guidance on vascular access choice, new targets for arteriovenous access (fistulas and grafts) and central venous catheters, management of specific complications, and renewed approaches to some older topics. Appraisal of the quality of the evidence was independently conducted by using a Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach, and interpretation and application followed the GRADE Evidence to Decision frameworks. As applicable, each guideline statement is accompanied by rationale/background information, a detailed justification, monitoring and evaluation guidance, implementation considerations, special discussions, and recommendations for future research.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Evaluation and management of central venous access complications.

            Venous access is 1 of the most common interventional procedures in the USA. Using image guidance in the last 2 decades, obtaining venous access has become increasingly routine, and the complications commonly associated with the procedure have significantly decreased. However, interventional radiologists still encounter both early and late complications routinely associated with both central and peripherally inserted access devices. This article discusses the most common and some unusual complications seen with the placement of these devices. We also briefly discuss the management of these complications.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A breakthrough technique for the removal of a hemodialysis catheter stuck in the central vein: endoluminal balloon dilatation of the stuck catheter.

              Joon Hong (2011)
              Hemodialysis (HD) catheters can get stuck in the central vein after long-term use and their removal might become difficult especially in patients with fibrosed or occluded central veins. Herein, a breakthrough technique is reported for the easy removal of a stuck HD catheter from the central vein.
                Bookmark

                Author and article information

                Contributors
                Cameron.Burnett@health.qld.gov.au
                Journal
                BMC Nephrol
                BMC Nephrol
                BMC Nephrology
                BioMed Central (London )
                1471-2369
                18 March 2024
                18 March 2024
                2024
                : 25
                : 104
                Affiliations
                [1 ]Department of Kidney and Transplantation Services, Princess Alexandra Hospital, ( https://ror.org/04mqb0968) Woolloongabba, QLD Australia
                [2 ]Department of Interventional Radiology, Princess Alexandra Hospital, ( https://ror.org/04mqb0968) Woolloongabba, QLD Australia
                [3 ]PA-Southside Clinic Unit, Faculty of Medicine, The University of Queensland, ( https://ror.org/00rqy9422) Brisbane, Australia
                Article
                3507
                10.1186/s12882-024-03507-z
                10949815
                38500070
                7fdd647f-8c20-4c1c-b8c4-cd8b772cf471
                © The Author(s) 2024

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 4 December 2023
                : 17 February 2024
                Categories
                Case Report
                Custom metadata
                © BioMed Central Ltd., part of Springer Nature 2024

                Nephrology
                central cuffed catheter,haemodialysis,stuck permcath,interventional radiology,case report

                Comments

                Comment on this article