          Abstract

          Background

          This report serves to describe the use of a novel adjustable single 8–0 polypropylene suture for scleral fixation without conjunctival dissection, and to describe related clinical outcomes associated with this approach.

          Methods

          In this study, we retrospectively reviewed 28 eyes from 27 patients that underwent scleral fixation of the intraocular lens (IOL) without conjunctival dissection using an adjustable single 8–0 polypropylene suture at the Beijing Tongren Eye Center between April 2018 and April 2019. For this surgical approach, a 23-gauge infusion cannula was set, after which two Hoffmann scleral pockets were created. Next, 8–0 polypropylene sutures were inserted into the eye guided by 10–0 polypropylene sutures of a long straight needle. The 8–0 suture was then used to fix the haptic IOs. Finally, these 8–0 polypropylene sutures were removed from the scleral pockets, and knots were tightened with the adjustable single suture. Primary outcomes included visual acuity and postoperative complication incidence.

          Results

          For this study, outcomes for 28 eyes from 27 patients (9 female, 18 male) were assessed. Patients had a mean age of 54 ± 15.11 years-old and were followed for an average of 10.18 ± 2.76 months postoperatively. Uncorrected visual acuity in these patients improved significantly from a preoperative value of 1.269 ± 0.464 logMAR to a 3-month postoperative value of 0.409 ± 0.413 logMAR ( p = 0.000). The majority of postoperative complications in these patients were temporary and self-limiting, including corneal edema (35.71%), hypotony (14.29%), elevated intraocular pressure (28.58%), and mild hyphema (7.14%). No evidence of exposure or erosion of the trimmed suture end was detected in any patients. An ultrasound biomicroscope was able to readily detect the IOL and all sutures, and IOLs were found to be well-centered without any dislocation, tilting, or subluxation upon follow-up.

          Conclusions

          An adjustable single 8–0 polypropylene suture can reliably and effectively be used for scleral fixation without conjunctival dissection for the treatment of patients with aphakia or inadequate posterior capsule support. The novel procedure described herein may therefore be an effective means of minimizing the risk of suture-related complications in patients undergoing scleral-fixated IOL implantation.

          Trial registration

          Retrospective case series study, not applicable. NCT04476264.

          Related collections

          Most cited references22

          • Record: found
          • Abstract: found
          • Article: not found

          Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection.

          To report a new technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (IOL).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Long-term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation.

            To investigate the long-term visual outcome and the complication rate following transscleral suture fixation of posterior chamber intraocular lenses (sutured PC-IOLs). A retrospective case-series descriptive study. Records of patients who underwent combined pars plana vitrectomy and sutured PC-IOLs at Moorfields Eye Hospital and who had at least 12 months of follow-up were examined for recorded complications. Sixty-one eyes of 48 patients (33 males and 15 females) were identified and included in the analysis, with mean follow-up of 6 years. The mean final best-corrected visual acuity remained at preoperative levels (P=.211) and was largely determined by the underlying ocular pathology before sutured PC-IOL. Overall 30 of 61 (49%) eyes, two or more procedures were performed to reverse a significant peri- or postoperative complication. Breakage of polypropylene sutures was the main indication accounting for 17 of 30 (57%) of those reoperations. Subgroup analysis showed that younger patients were more likely to suffer the above complication (P=.009). The multivariate analysis also showed that longer follow-up was significantly associated with suture breakage (P=.014), with the mean time to breakage approximately 4 years after surgery. Long-term follow-up of patients undergoing sutured PC-IOLs appears to be associated with a high rate of postoperative complications and significant need for further surgery, which should be discussed during their informed consent process.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Techniques of intraocular lens suspension in the absence of capsular/zonular support.

              Implantation of intraocular lenses has become the standard of care in the aphakic state. Ideally, the lens is placed in the capsular bag, which affords stable fixation at a position closest to the nodal point of the eye. However, there will always be instances where this will not be possible. Congenital weakness of the lens zonules in various conditions, trauma, and surgical complications of cataract surgery are just some examples. In this article, we review the methods that have been devised to allow intraocular lens implantation in the absence of capsular or zonular support. These include anterior chamber angle and iris-fixated lenses, as well as posterior chamber iris- and scleral-sutured lenses. The various lenses are described, and the techniques involved, advantages and disadvantages, complications, and results of each method are discussed. It is hoped that this article will provide a comprehensive overview of ways to deal with a problem that can still result in a very good visual outcome for the patient. This is particularly relevant given the many recent developments and refinements of methods in implanting intraocular lenses.
                Bookmark

                Author and article information

                Contributors
                Lsf_0309@163.com
                Journal
                BMC Ophthalmol
                BMC Ophthalmol
                BMC Ophthalmology
                BioMed Central (London )
                1471-2415
                25 July 2020
                25 July 2020
                2020
                : 20
                : 304
                Affiliations
                GRID grid.24696.3f, ISNI 0000 0004 0369 153X, Beijing Tongren Eye Center, Beijing Ophthalmology & Visual Sciences Key Laboratory, , Beijing Tongren Hospital, Capital Medical University, ; No. 1 Dong Jiao Min Xiang, Eastern District, Beijing, 100730 China
                Author information
                http://orcid.org/0000-0003-4613-0997
                Article
                1558
                10.1186/s12886-020-01558-y
                7382057
                32711502
                749b9dc9-4939-436c-a70e-dad5c381a52a
                © The Author(s) 2020

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 1 November 2019
                : 7 July 2020
                Categories
                Research Article
                Custom metadata
                © The Author(s) 2020

                Ophthalmology & Optometry
                transscleral suture fixation,adjustable,8–0 polypropylene suture,without conjunctival dissection

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content390

                Cited by8

                Most referenced authors199