      Primary Total Hip Arthroplasty Using Third Generation Ceramic-Ceramic Articulation: Results after a Minimum of Three-years of Follow-up

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          This study assessed the short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems.

          Materials and Methods

          Two hundred and seventy two patients (294 hips) with primary total hip arthroplasty using third generation ceramic-ceramic articulation Accolade TMZF femoral stems who had been followed-up for a minimum of 3 years were included. Clinicoradiological results were analyzed and postoperative complications were observed.

          Results

          At final follow-up, mean Harris hip score was increased from 52 to 94 points. On radiogical evaluation, the average acetabular inclination was 42 degrees and the average acetabular anteversion was 15 degrees. Neither osteolysis nor loosening were observed around the acetabulum or proximal femur. Among 294 acetabular cups, 293 cups (99.66%) achieved stable fixation. Regarding the 294 femoral stems, 286 (97.28%) had bony fixation, 7 (2.38%) had fibrous fixation, and none were found to have unstable stem fixation. Proximal bone resorption was observed in 17 hips (5.78%; only Grade 1) and radiolucent lines were observed in 88 hips (29.93%), however, all were around the distal smooth portion of the stems. Postoperative complications included dislocation in 6 hips (2.04%), heterotopic ossification in 3 hips (1.02%), ceramic fractures in 4 hips (1.36%), superficial infection in 1 hip (0.34%), and squeaking in 8 hips (2.72%).

          Conclusion

          The short term clinicoradiological results of primary total hip arthroplasty using third generation ceramic-ceramic articulation and Accolade TMZF femoral stems together with Secur-Fit acetabular cups were satisfactory. However, problems such as ceramic fractures and squeaking after arthroplasty were observed. Additional studies are necessary in order to develop methods that may reduce or eliminate these complications.

          Related collections

          Most cited references35

          • Record: found
          • Abstract: not found
          • Article: not found

          Ectopic ossification following total hip replacement. Incidence and a method of classification.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components.

            Certain roentgenographic signs have value in predicting the fixation of a cementless femoral component to bone by osseointegration. Other signs have value in predicting the gross stability of a cementless femoral component. The authors have determined the specificity and sensitivity of the signs for osseointegration in cases in which the histologic fixation has been confirmed after implant removal. The authors have also determined the specificity and sensitivity of the signs for gross implant stability in cases in which the stability has been confirmed at reoperation. Statistical methods were used to determine a numeric value for each of these roentgenographic signs, and these values were combined into a score. The score was divided into fixation by osseointegration and mechanical implant stability. The two scores were then combined into an overall score. When signs of osseointegration were present, the implant was always stable, and the overall scores were the highest. When signs of osseointegration were absent, the mechanical stability varied, and the scores were lower. A neutral or slightly negative score correlated with failed osseointegration but secondary successful implant stabilization. A very low negative score correlated with gross implant instability. To confirm the validity of the scoring system, the two-year postoperative score was determined for 1005 cases in which the clinical outcome was known. A strong correlation between the presence of symptoms and a low score confirmed the value of the scoring system for diagnosing implant loosening as the cause of symptoms. As a second test, the two-year and five-year postoperative results were compared in the same patients. A high two-year score correlated with durable implant stability through five years. A low two-year score correlated with a higher incidence of late symptomatic loosening.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Radiological demarcation of cemented sockets in total hip replacement.

              The frequency of radiological demarcation of the cement-bone junction in the acetabulum after total hip replacement has been examined in 141 Charnley low-friction arthroplasties followed for an average of 10.1 years. Sixty-nine per cent showed demarcation of various degrees and 9.2 per cent of the series showed evidence of progressive migration of the socket. The vast majority of cases with demarcation were symptomless. In most cases where demarcation was accompanied by migration the operation notes suggested a technical explanation and in three cases low-grade sepsis was responsible. The fact that nearly 30 per cent of cases showed no demarcation even after 10 years supports the idea that there is no fundamental defect in the principle of employing cement in the acetabulum. Better surgical technique may increase the number of cases showing no demarcation.
                Bookmark

                Author and article information

                Journal
                Hip Pelvis
                Hip Pelvis
                HP
                Hip & Pelvis
                Korean Hip Society
                2287-3260
                2287-3279
                June 2014
                30 June 2014
                : 26
                : 2
                : 84-91
                Affiliations
                Department of Orthopedics, Yonsei University Wonju College of Medicine, Wonju, Korea.
                Author notes
                Address reprint request to Sung Kwan Hwang, MD. Department of Orthopedics, Yonsei University Wonju College of Medicine, 20 Ilsan-ro, Wonju 220-701, Korea. TEL: +82-33-741-1351, FAX: +82-33-741-1365, hwtonlka@ 123456wonju.yonsei.ac.kr
                Article
                10.5371/hp.2014.26.2.84
                4971121
                27536564
                68a5359b-dd1e-4a20-91db-952820566ad3
                Copyright © 2014 by Korean Hip Society

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 23 April 2014
                : 12 June 2014
                : 16 June 2014
                Categories
                Original Article

                third generation ceramic-ceramic articulation,primary total hip arthroplasty,harris hip score

                Comments

                Comment on this article