          Abstract

          Purpose:

          To compare the safety and efficacy of three methods for correcting pre-existing astigmatism during phacoemulsification.

          Methods:

          This prospective, comparative, non-randomized study was conducted from March 2010 to January 2011, and included patients with keratometric astigmatism ≥1.25 D undergoing cataract surgery. Astigmatism was corrected using the following approaches: limbal relaxing incisions (LRI) on the steep meridian, extension and suturing of the phaco incision created at the steep meridian (extended-on-axis incision, EOAI), and toric intraocular lens (tIOL) implantation. Keratometric and refractive astigmatism were evaluated 1, 8, and 24 weeks postoperatively.

          Results:

          Eighty-three eyes of 72 patients (35 male and 37 female) with mean age of 62.4 ± 14.3 (range, 41-86) years were enrolled. The astigmatism was corrected by using the LRI, EOAI and tIOL implantation methods in 17, 33 and 33 eyes, respectively. Postoperative uncorrected distance visual acuity (UDVA) was significantly improved in all three groups. The difference in postoperative UDVA was not statistically significant among the study groups throughout follow-up except at week 24, when UCVA was significantly better in the tIOL group as compared to the EOAI group ( P = 0.024). There is no statistically significant difference of correction index and index of success between three groups at week 24 ( P = 0.085 and P = 0.085 respectively).

          Conclusion:

          There was no significant difference in astigmatism reduction among the three methods of astigmatism correction during phacoemulsification. Each of these methods can be used at the discretion of the surgeon.

          Related collections

          Most cited references33

          • Record: found
          • Abstract: not found
          • Article: not found

          Biometry of 7,500 cataractous eyes.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Comparison of toric intraocular lenses and peripheral corneal relaxing incisions to treat astigmatism during cataract surgery.

            To evaluate and compare toric intraocular lens (IOL) implantation and spherical IOL implantation with peripheral corneal relaxing incisions to manage astigmatism during phacoemulsification. Ophthalmology Service, Hospital Ramón y Cajal, Madrid, Spain. Prospective randomized comparative case series. Eyes with cataract and corneal astigmatism (1.00 to 3.00 diopters [D]) had toric IOL implantation or peripheral corneal relaxing incisions. Outcome measures were visual outcomes, slitlamp assessment, digital toric IOL axis determination, spectacle need, and patient satisfaction. Three months postoperatively, the mean uncorrected distance visual acuity (UDVA) was 0.13 ± 0.10 (SD) in the toric IOL group and 0.19 ± 0.12 in the relaxing incisions group; the UDVA was better than 0.20 in 75% of eyes and 60% of eyes, respectively. Refractive cylinder decreased significantly in both groups, with a mean residual refractive astigmatism of 0.61 ± 0.41 D in the toric IOL group and 1.32 ± 0.60 D in the relaxing incisions group (P<.01). The mean toric IOL rotation was 3.65 ± 2.96 degrees, with no significant differences between slitlamp and digital photograph measurements. There was a trend toward better mesopic contrast sensitivity with glare in the toric IOL group. There were no differences in VF-14 or patient satisfaction results; 15% of patients in the toric IOL group and 45% in the relaxing-incision group required distance spectacles postoperatively. Although refractive astigmatism decreased in both groups, toric IOL implantation was more effective and predictable, resulting in greater spectacle independence. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Toric intraocular lens implantation: 100 consecutive cases.

              To evaluate the first 100 consecutive cases of toric posterior chamber silicone intraocular lens (IOL) implantation by 2 community-based ophthalmologists. Two private practices in western Virginia, USA. Data on the first 100 consecutive toric IOL implantations in 81 patients were collected in a prospective manner. Cataract surgery was performed using topical anesthesia and phaco-chop, phaco-flip, or divide-and-conquer phacoemulsification. A Staar AA4203TF or AA4203TL IOL with a 2.00 diopter (D) or 3.50 D toric power was implanted using a lens injector. After the viscoelastic material was removed, the IOL was rotated to the desired orientation. The IOL orientation was assessed postoperatively at 1 day, 1 to 2 weeks, and the last visit. The mean follow-up was 23 weeks +/- 17 (SD). The IOLs performed in a predicable fashion. The mean astigmatism correction with IOLs within 15 degrees of the intended axis was 1.62 D with the 2.00 D IOL and 2.86 D with the 3.50 D IOL. Eleven patients had IOLs that were rotated more than 15 degrees away from the intended axes; in 3, the astigmatism was worse than preoperatively. The mean preoperative refractive and keratometric astigmatism was 2.48 D and 2.11 D, respectively. The mean postoperative astigmatism was 0.87 D and 2.05 D, respectively. At the last follow-up, half the patients had residual refractive astigmatism of 0.50 D or less and 45% had an uncorrected visual acuity of 20/30 or better. Of postoperative patients with a 20/30 visual acuity with or without correction, 52% could see this well no correction. The results show that toric IOL implantation can help an estimated 20% of patients with astigmatism achieve good vision and a reduced need for distance spectacles. If IOL rotation occurs, it is usually during the first week and can be remedied by repositioning the IOL at 1 week.
                Bookmark

                Author and article information

                Journal
                J Ophthalmic Vis Res
                J Ophthalmic Vis Res
                JOVR
                Journal of Ophthalmic & Vision Research
                Medknow Publications & Media Pvt Ltd (India )
                2008-2010
                2008-322X
                Apr-Jun 2016
                : 11
                : 2
                : 162-167
                Affiliations
                [1 ] Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
                [2 ] Torfeh Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
                [3 ] Department of Orthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
                [4 ] Ophthalmic Epidemiology Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
                [5 ] Eye Research Center, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran
                [6 ] Ocular Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
                Author notes
                Correspondence to: Goldis Espandar, MD. Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, No. 23, Paidarfard St., Boostan 9 St., Pasdaran Ave., Tehran 16666, Iran. E-mail: goldis_espandar@ 123456yahoo.com
                Article
                JOVR-11-162
                10.4103/2008-322X.183924
                4926563
                27413496
                68309d26-dc47-45bc-bc6e-13079c9191ed
                Copyright: © Journal of Ophthalmic and Vision Research

                This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

                History
                : 04 May 2015
                : 06 February 2016
                Categories
                Original Article

                Ophthalmology & Optometry
                astigmatism correction,extended-on-axis incision,limbal relaxing incision,phacoemulsification,toric intraocular lens

                Comments

                Comment on this article