      Reply: Matters Arising ‘Investigating sources of inaccuracy in wearable optical heart rate sensors’

      letter

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Replying to : Colvonen et al. npj Digital Medicine 10.1038/s41746-021-00408-5 (2021) This is a response to the Matters Arising (MA) that examines our original article, ‘Investigating inaccuracies in wearable optical heart rate sensors’ 1 . We performed this original study to address the concern that there was inadequate published research on the potential effect of skin tone on wearable device accuracy. The central hypothesis tested in the original study was that darker skin tones have decreased photoplethysmography-based heart rate measurement accuracy as compared with lighter skin tones. The MA suggests improvements surrounding two aspects of the original study: the sample size and the use of the Fitzpatrick skin tone (FP) scale to categorize skin tones. The original study was designed and powered according to the above hypothesis. We acknowledge that visual skin tone scales are imperfect, and that a study can never prove the null hypothesis to be true. We, too, encourage more work examining wearable device accuracy across skin tones. In this reply, we aim to address questions surrounding the sample size, covariates, and choice of skin tone scale in the original article. The two overarching analyses planned for the original study were an Analysis of Variance (ANOVA) to test for a difference in means of heart rate accuracy between FP skin tone groups, and a mixed effects regression model to explore potential effects of wearable device type and activity type during wear. To achieve 80% power to reject the null hypothesis that there is no difference in heart rate accuracy between the six FP groups (∝ = 0.5), we concluded that 48 participants were needed overall, with eight participants in each of the skin tone categories for the ANOVA and 46 needed for the mixed effects model (f2 = 0.15). We acknowledge that power analyses are imperfect sample size calculation tools and that domain-knowledge based decisions must be made to define the parameters of the power analysis. Here, a medium effect size of 0.3 was chosen based on a pilot study examining differences in green light absorption across skin tones on the FP scale 2 . In this study, we recruited and enrolled an approximately equal distribution of skin tones to meet our power requirements (with 7, 8, 10, 9, 9, and 10 participants, respectively, for FP groups 1–6). In the MA it is suggested that there should be an increased number of participants in FP6. Addressing concerns raised in the MA of greater heterogeneity in darker skin tone groups, we did not find differences in variance of heart rate measurements or their errors across skin tone groups (Fig. 2). Overall, we recommend a statistically-based justification for all sample size choices. Given established effects of movement on PPG heart rate accuracy 3–6 , in the original study we comprehensively explored potential interaction between skin tone and level of activity (Fig 2). No interaction effects were found that could not be directly attributed to the differences among activity (Fig. 3). We also did not find any relationship between weight, BMI, and body fat percentage and heart rate accuracy or any interaction with skin tone. Potential covariates proposed in the MA that were not measured in the original study include arm hair, sweat, and thickness of skin epidermis. We are aware that skin epidermal thickness can be measured with appropriate optical equipment 7 and should be explored in future studies; however, the other factors are more difficult to quantify. Further, increasing the number of covariates measured increases the time it takes to run each participant through the study and also increases the sample size needed for statistical analysis. Lastly, our literature review did not uncover any publications demonstrating an effect of arm hair, sweat, or ambient temperature on PPG measurements (PubMed, 9/2/2020; search terms: interaction AND hair AND PPG OR pulse oximetry OR Photoplethysmograph; interaction AND sweat AND PPG OR pulse oximetry OR Photoplethysmograph; interaction AND temperature AND PPG OR pulse oximetry OR Photoplethysmograph). For practical study implementation, we recommend demonstrably quantifiable covariates with a literature-based justification for their inclusion in the study design. The current gold standard of measuring skin tone is the Fitzpatrick Phototype (FP) Skin Type Scale, which divides the spectrum of skin tones into six ordered categories. We fully agree that there are inherent issues with both the visual assessment of skin tone and with the FP scale specifically, which was not developed initially for the full spectrum of skin tones 11 . The later addition to FP of two darker skin tone categories underscores that FP must be treated as an ordinal rather than interval variable in analysis. However, we disagree with the premise that there is no value in visual assessment methods and with the assertion that it is well established that FP has weak correlation with skin color. Specifically, two of the three references cited in the MA to support this claim do not actually assess FP 8,9 . We explored the works cited by these three references and found just one study of 43 Thai volunteers used to support the references’ claims 10,11 . On the other hand, multiple studies in diverse populations have shown that skin color evaluation with a spectrophotometer is correlated with visual skin tone assessment 12–14 . An interesting idea proposed in the MA is to replace subjective skin tone scales with objective reflectance spectrometry. Next, we discuss the pros and cons of spectrometry versus visual skin tone assessment and make recommendations based on our own study experience. Spectrometry benefits from objective technology-based measurements, however, it requires specialized equipment and the measurements can be affected by not only skin tone, but also by tissue composition (e.g., tissue hydration status 15 ). While spectrometry can reduce subjectivity associated with commonly used visual skin tone assessment, there is an increased cost of collecting and analyzing spectrometry data. We believe that requiring its use increases the barrier to entry for including skin tone as a variable in wearables accuracy studies and may thus limit the number of future studies performed in this space, which is in opposition to both our own and the MA author’s objectives. We do believe that new technology development may lower this barrier to entry. Best practices 16 for spectrophotometry measures and potential sources of error (e.g., whether other tissue components aside from melanin content can affect spectrometry measurements) will need to be established for consistent and comparable assessment across studies 17 . On the other hand, visual scales are lower cost, more accessible, and therefore more commonly used in research studies. However, using visual scales properly requires a trained research technician to perform all study measurements, a single printed reference color palette used for every observation, and consistent ambient lightning. Visual scales may also be subject to administrator bias. In both objective and subjective measurement methods, human error may be introduced through improper measurement methodology. In the original study, we used both objective hand-held spectrophotometer measurements (LinkSquare, Stratio Inc) as well as two separate and independently assessed subjective visual assessments using the FP and von Luschan skin tone scales (Supplementary Table 10). For every visual assessment, the same printed FP and von Luschan scale color palette was used by the same study administrator in the same room with the same lighting. Each color swatch was placed on the wrist location where the smart watch sensor would lay, and the closest color match was chosen by the study administrator. In the original publication, we only reported the data from the two visual assessment methods (FP vs. von Luschan Spearman correlation 0.98, p = 2.2e−16) because we did not find differences in the spectrometry measurements across even the most divergent skin tone groups (FP1 vs. FP6; nonsignificant pairwise Wilcoxon Rank Sum Test), indicating that there was either an equipment error or that there are other factors involved in the spectrometry measurements such as tissue content that do not relate only to skin tone. This was a limitation in our original study that may be addressed through using well-evaluated equipment commonly used for objective skin tone measurements. Recently, others have demonstrated success with objective skin tone measurements using spectrocolorimetry with the Chromasphere® (L’Oréal, Paris, France) and Datacolor microflash spectrocolorimeter (Datacolor, Montreuil, France) tools 18,19 , which differ from the spectrophotometry method we used by Linksquare Stratio Inc. This presents a potential alternative approach for objective measurements of skin tone and has been recently utilized in a study for VO2max accuracy in smartphones across skin tones 19 . Our goals are aligned with the MA author ‘to fully and accurately represent the possible limitations of PPG technology for individuals with dark skin to limit any unintentional contributions to health disparities’. We hope that by providing a framework for including skin tone as a variable in device accuracy assessments and by piloting this methodology on five of the leading wearables used currently in clinical research, we have demonstrated that this is an important and accessible analysis. A key area that we believe is critical for the future of this field is to broaden the application of this study framework to all devices used in clinical research under a wider variety of circumstances of use, so that we can better capture the range of real-world scenarios where data would be collected and used for clinical or research purposes. It is also critical to continue this research as hardware and software continue to evolve, and to understand how software updates can change accuracy of wearable device measurements. Wearables companies and/or researchers using these products can and should use this methodology in appropriately powered, Institutional Review Board-approved studies to evaluate the accuracy of their devices across the full spectrum of skin tones.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort

          The ability to measure physical activity through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. The aim of this work is to assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males, greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. In conclusion, most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices (http://precision.stanford.edu/).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Verification, analytical validation, and clinical validation (V3): the foundation of determining fit-for-purpose for Biometric Monitoring Technologies (BioMeTs)

            Digital medicine is an interdisciplinary field, drawing together stakeholders with expertize in engineering, manufacturing, clinical science, data science, biostatistics, regulatory science, ethics, patient advocacy, and healthcare policy, to name a few. Although this diversity is undoubtedly valuable, it can lead to confusion regarding terminology and best practices. There are many instances, as we detail in this paper, where a single term is used by different groups to mean different things, as well as cases where multiple terms are used to describe essentially the same concept. Our intent is to clarify core terminology and best practices for the evaluation of Biometric Monitoring Technologies (BioMeTs), without unnecessarily introducing new terms. We focus on the evaluation of BioMeTs as fit-for-purpose for use in clinical trials. However, our intent is for this framework to be instructional to all users of digital measurement tools, regardless of setting or intended use. We propose and describe a three-component framework intended to provide a foundational evaluation framework for BioMeTs. This framework includes (1) verification, (2) analytical validation, and (3) clinical validation. We aim for this common vocabulary to enable more effective communication and collaboration, generate a common and meaningful evidence base for BioMeTs, and improve the accessibility of the digital medicine field.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Investigating sources of inaccuracy in wearable optical heart rate sensors

              As wearable technologies are being increasingly used for clinical research and healthcare, it is critical to understand their accuracy and determine how measurement errors may affect research conclusions and impact healthcare decision-making. Accuracy of wearable technologies has been a hotly debated topic in both the research and popular science literature. Currently, wearable technology companies are responsible for assessing and reporting the accuracy of their products, but little information about the evaluation method is made publicly available. Heart rate measurements from wearables are derived from photoplethysmography (PPG), an optical method for measuring changes in blood volume under the skin. Potential inaccuracies in PPG stem from three major areas, includes (1) diverse skin types, (2) motion artifacts, and (3) signal crossover. To date, no study has systematically explored the accuracy of wearables across the full range of skin tones. Here, we explored heart rate and PPG data from consumer- and research-grade wearables under multiple circumstances to test whether and to what extent these inaccuracies exist. We saw no statistically significant difference in accuracy across skin tones, but we saw significant differences between devices, and between activity types, notably, that absolute error during activity was, on average, 30% higher than during rest. Our conclusions indicate that different wearables are all reasonably accurate at resting and prolonged elevated heart rate, but that differences exist between devices in responding to changes in activity. This has implications for researchers, clinicians, and consumers in drawing study conclusions, combining study results, and making health-related decisions using these devices.
                Bookmark

                Author and article information

                Contributors
                jessilyn.dunn@duke.edu
                Journal
                NPJ Digit Med
                NPJ Digit Med
                NPJ Digital Medicine
                Nature Publishing Group UK (London )
                2398-6352
                26 February 2021
                26 February 2021
                2021
                : 4
                : 39
                Affiliations
                [1 ]GRID grid.26009.3d, ISNI 0000 0004 1936 7961, Department of Biomedical Engineering, , Duke University, ; Durham, NC USA
                [2 ]GRID grid.26009.3d, ISNI 0000 0004 1936 7961, Department of Biostatistics and Bioinformatics, , Duke University School of Medicine, ; Durham, NC USA
                Author information
                http://orcid.org/0000-0002-7039-0177
                http://orcid.org/0000-0002-9541-0058
                http://orcid.org/0000-0001-5622-7659
                http://orcid.org/0000-0002-3241-8183
                Article
                409
                10.1038/s41746-021-00409-4
                7910441
                33637842
                62299fd0-a1e0-4b19-8933-31735e823db9
                © The Author(s) 2021

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 13 September 2020
                : 26 January 2021
                Funding
                Funded by: Whitehead Scholar
                Funded by: Forge Fellow
                Categories
                Matters Arising
                Custom metadata
                © The Author(s) 2021

                peer review,imaging and sensing
                peer review, imaging and sensing

                Comments

                Comment on this article