      [An analysis of measurement error in Orbscan topography system].

      [Zhonghua yan ke za zhi] Chinese journal of ophthalmology
      Adolescent, Adult, Anterior Chamber, pathology, Cornea, surgery, Corneal Topography, methods, standards, Female, Humans, Keratomileusis, Laser In Situ, Lasers, Excimer, Male, Middle Aged, Photorefractive Keratectomy, Reproducibility of Results

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To discuss the measurement error and the influence factor of Orbscan Topography to provide more accurate data for clinical application. Orbscan Topography System and A-scan ultrasonography were used to measure the corneal thickness and anterior chamber depths pre-operatively and post-operatively, including 200 cases (400 eyes) undergoing laser in situ keratomileusis (Lasik) and 50 cases (100 eyes) undergoing photorefractive keratectomy (PRK). The curvature of posterior corneal surface was measured by Orbscan topography before and after the operations, and the result of measurement was compared. Pre-operatively, the value of corneal thickness was (18.83 - 24.29) microm lower measured by Orbscan topography than that by A-ultrasonography, and post-operatively the value was (56.32 - 139.52) micro m lower than that by A-ultrasonography. The postoperative value was obviously higher than the pre-operative one. The value of central anterior chamber depth was (0.16 - 0.25) mm lower measured by Orbscan system than that by A-ultrasonography pre-operatively and post-operatively. There was no clinical significance. The difference in the comparison of posterior corneal surface curvature before and after Lasik was -0.60 D measured by Orbscan System. The difference in the comparison of posterior corneal surface curvature before and after PRK was -0.51 D in the lower diopter group and -1.12 D in medium diopter group. It is necessary to improve the accuracy of Orbscan Topography System. The Haze and the change of anterior corneal surface curvature after Lasik and PRK are the main causes of measurement error in Orbscan Topography System. Clinically, it is an un-negligible important problem in the measurement of Orbscan system.

          Related collections

          Author and article information

          Comments

          Comment on this article