      Recent Advances in Electrochemical and Optical Biosensors Designed for Detection of Interleukin 6

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Interleukin 6 (IL-6), being a major component of homeostasis, immunomodulation, and hematopoiesis, manifests multiple pathological conditions when upregulated in response to viral, microbial, carcinogenic, or autoimmune stimuli. High fidelity immunosensors offer real-time monitoring of IL-6 and facilitate early prognosis of life-threatening diseases. Different approaches to augment robustness and enhance overall performance of biosensors have been demonstrated over the past few years. Electrochemical- and fluorescence-based detection methods with integrated electronics have been subjects of intensive research due to their ability to offer a better signal-to-noise ratio, high specificity, ultra-sensitivity, and wide dynamic range. In this review, the pleiotropic role of IL-6 and its clinical significance is discussed in detail, followed by detection schemes devised so far for their quantitative analysis. A critical review on underlying signal amplification strategies and performance of electrochemical and optical biosensors is presented. In conclusion, we discuss the reliability and feasibility of the proposed detection technologies for commercial applications.

          Related collections

          Most cited references159

          • Record: found
          • Abstract: found
          • Article: not found

          Complementary DNA for a novel human interleukin (BSF-2) that induces B lymphocytes to produce immunoglobulin.

          When stimulated with antigen, B cells are influenced by T cells to proliferate and differentiate into antibody-forming cells. Since it was reported that soluble factors could replace certain functions of helper T cells in the antibody response, several different kinds of lymphokines and monokines have been reported in B-cell growth and differentiation. Among these, human B-cell differentiation factor (BCDF or BSF-2) has been shown to induce the final maturation of B cells into immunoglobulin-secreting cells. BSF-2 was purified to homogeneity and its partial NH2-terminal amino-acid sequence was determined. These studies indicated that BSF-2 is functionally and structurally unlike other known proteins. Here, we report the molecular cloning, structural analysis and functional expression of the cDNA encoding human BSF-2. The primary sequence of BSF-2 deduced from the cDNA reveals that BSF-2 is a novel interleukin consisting of 184 amino acids.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Polydopamine--a nature-inspired polymer coating for biomedical science.

            Polymer coatings are of central importance for many biomedical applications. In the past few years, poly(dopamine) (PDA) has attracted considerable interest for various types of biomedical applications. This feature article outlines the basic chemistry and material science regarding PDA and discusses its successful application from coatings for interfacing with cells, to drug delivery and biosensing. Although many questions remain open, the primary aim of this feature article is to illustrate the advent of PDA on its way to become a popular polymer for bioengineering purposes.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Interleukin-6 triggers the association of its receptor with a possible signal transducer, gp130.

              Interleukin-6 mediates pleiotropic functions in various types of cells through its specific receptor (IL-6-R), the cDNA of which has already been cloned. We report here that an 80 kd single polypeptide chain (IL-6-R) is involved in IL-6 binding and that IL-6 triggers the association of this receptor with a non-ligand-binding membrane glycoprotein, gp130. The association takes place at 37 degrees C within 5 min and is stable for at least 40 min in the presence of IL-6, but does not occur at 0 degree C. Human IL-6-R can associate with a murine gp130 homolog and is functional in murine cells. Mutant IL-6-R lacking the intracytoplasmic portion is functional, suggesting that the two polypeptide chains interact to involve their extracellular portion. In fact, a soluble IL-6-R lacking the transmembrane and intracytoplasmic domains can associate with gp130 in the presence of IL-6 and mediate its function. These findings indicate that the complex of IL-6 and IL-6-R can interact with a non-ligand-binding membrane glycoprotein, gp130, extracellularly and can provide the IL-6 signal.
                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                23 January 2020
                February 2020
                : 20
                : 3
                : 646
                Affiliations
                [1 ]School of Chemical and Materials Engineering, National University of Sciences & Technology, H-12, Islamabad 44000, Pakistan; m.mujahid@ 123456stcatz.oxon.org
                [2 ]School of Materials Sciences & Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798, Singapore
                [3 ]Pak-Austria Fachhochshule, Institute of Applied Sciences & Technology, Khanpur Road, Mang, Haripur 22650, Pakistan
                Author notes
                [* ]Correspondence: munezza.phd@ 123456scme.nust.edu.pk ; Tel.: +92-321-3830-957
                [†]

                These authors contributed equally to this work.

                Author information
                https://orcid.org/0000-0002-0368-8280
                https://orcid.org/0000-0002-3454-0713
                Article
                sensors-20-00646
                10.3390/s20030646
                7038342
                31979357
                54f99e0b-464c-48f4-bb85-e10b32286284
                © 2020 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 11 November 2019
                : 18 December 2019
                Categories
                Review

                Biomedical engineering
                interleukin 6,biosensor,cancer detection,electrochemical sensor,optical sensor