9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery : An updated meta-analysis

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Supplemental Digital Content is available in the text

          Abstract

          Background:

          Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO.

          Methods:

          Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies.

          Results:

          Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16–0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: −1.32, 95% CI = −2.39 to −0.25, P = .015) and estimated PCO score (diff. in means: −2.23; 95% CI, −3.80 to −0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: −0.075; 95% CI, −0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: −0.016; 95% CI, −0.041 to 0.009, P = .208).

          Conclusion:

          In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.

          Related collections

          Most cited references24

          • Record: found
          • Abstract: found
          • Article: not found

          A systematic overview of the incidence of posterior capsule opacification.

          Reported rates of posterior capsule opacification (PCO) vary widely and are based on various definitions of PCO, varying lengths and intervals of follow-up, and the use of different surgical techniques, intraocular lens (i.o.l.) designs, and methods of IOL implantation. This study was designed to obtain a more precise overall estimate of the incidence of PCO and to explore factors that might influence the rate of PCO development. A meta-analysis. Published articles were selected for study based on a computerized MEDLINE search of the literature and a manual search of the bibliographies of relevant articles. Articles meeting selected inclusion criteria were reviewed systematically, and the reported data were abstracted and synthesized using the statistical techniques of meta-analysis. Pooled estimates of the proportion of eyes developing PCO at three postoperative timepoints--1 year, 3 years, and 5 years--were measured. There is significant heterogeneity among published rates of PCO. The overall pooled estimates (95% confidence limits) of the incidence of PCO were 11.8% (9.3%-14.3%) at 1 year, 20.7% (16.6%-24.9%) at 3 years, and 28.4% (18.4%-38.4%) at 5 years after surgery. There is no evidence of a significant decline in PCO incidence during the study period. Visually significant PCO develops in more than 25% of patients undergoing standard extracapsular cataract extraction or phacoemulsification with posterior chamber intraocular lens implantation over the first 5 years after surgery. Patient characteristics, surgical techniques, and differences in research design and reporting may account for some of the variability in reported rates. However, no specific factors were identified in the authors' analysis. More precise estimates of incidence and identification of risk factors for PCO will depend on the development of a standardized measurement of PCO and wider adoption of more rigorous study methodology.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem.

            (1) To report the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate (%) of eight rigid and foldable intraocular lens (IOL) designs in a series of 5416 pseudophakic human eyes obtained postmortem, accessioned in our center between January 1988 and January 2000. (2) To identify factors that are instrumental in reducing the incidence of posterior capsule opacification, (PCO, secondary cataract) and hence the need for Nd:YAG laser posterior capsulotomy. Comparative autopsy tissue analysis. A total of 5416 globes with posterior chamber intraocular lens (PC-IOLs) obtained postmortem received from Lions Eye Banks between 1988 and 2000. Miyake-Apple posterior photographic technique. Special reference was given to the presence or absence of Nd:YAG laser posterior capsulotomy orifice on the posterior capsule of each eye. The Nd:YAG laser posterior capsulotomy rate (%) as of January 2000 was documented. In addition, the Nd:YAG laser posterior capsulotomy rate for each lens was plotted on a monthly basis for the same period, creating a computerized trend or "timeline" for each IOL style. Relatively high Nd:YAG laser posterior capsulotomy rates ranging from 20.3% to 33.4% were noted with four relatively older designs (high incidence of implantation between 1988 and the early 1990s). Four modern foldable IOLs manufactured from silicone and acrylic materials had significantly lower Nd:YAG laser posterior capsulotomy rates ranging from 0.9% (Alcon Acrysof) to 17.1%. The difference in Nd:YAG rates among the eight IOL designs was found to be significant (P < 0.0001, chi-square test). Comparing foldable versus rigid designs, the foldable IOLs were associated with a much lower Nd:YAG laser posterior capsulotomy rate (14.1% vs. 31.1%). By use of the six factors regarding surgical technique and IOL choice described in this article, we strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing from rates as high as 50% in the 1980s to early 1990s. Surgical tools and IOLs are now available to bring these rates down to single digits. Careful application and use of these tools by surgeons can genuinely lead in the direction of virtual eradication of secondary cataract, the second most common cause of visual loss worldwide.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Effect of intraocular lens design on posterior capsule opacification.

              Posterior capsule opacification (PCO) remains the most common long-term complication after cataract surgery. Many studies have attempted to identify factors that influence the development of PCO. The aim of this systematic review based on Cochrane methodology was to summarize the effects of intraocular lens (IOL) geometry, including modifications of the IOL optic (especially optic edge design) and haptics, on the development of PCO. Twenty-six prospective randomized controlled trials with a follow-up of at least 12 months were included. In 5 of 7 studies, visual acuity was better in sharp-edged IOLs than in round-edged IOL. The PCO score was significantly lower with sharp-edged IOLs but did not differ significantly between 1-piece and 3-piece open-loop IOLs. Because of the significant difference in the PCO score, sharp-edged IOL optics should be preferred to round-edged IOL optics.
                Bookmark

                Author and article information

                Journal
                Medicine (Baltimore)
                Medicine (Baltimore)
                MEDI
                Medicine
                Wolters Kluwer Health
                0025-7974
                1536-5964
                November 2017
                03 November 2017
                : 96
                : 44
                : e8301
                Affiliations
                [a ]Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing
                [b ]Medical School, Pingdingshan University, Pingdingshan
                [c ]Department of ophthalmology, the Chinese People's Liberation Army General Hospital, Beijing, China.
                Author notes
                []Correspondence: Siquan Zhu, Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Tongren Hospital, Capital Medical University, 1 Dongjiaominxiang Dongcheng District, Beijing 100073, China (e-mail: siquan10@ 123456yeahmca.c n ).
                Article
                MD-D-17-05230 08301
                10.1097/MD.0000000000008301
                5682778
                29095259
                5400cc1e-c4dd-4ac8-9f2d-b264cd794a5d
                Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc.

                This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0

                History
                : 21 August 2017
                : 20 September 2017
                : 25 September 2017
                Categories
                5800
                Research Article
                Systematic Review and Meta-Analysis
                Custom metadata
                TRUE

                biomaterial,cataract,hydrophilic,hydrophobic,intraocular lens,nd:yag laser capsulotomy,posterior capsule opacification

                Comments

                Comment on this article