2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Design and fabrication of a thoracic phantom for radiation dose verification in mega-voltage X-ray beam

      , , , ,
      Materials Today: Proceedings
      Elsevier BV

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references13

          • Record: found
          • Abstract: found
          • Article: not found

          Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

          Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review aimed at improving the understanding and consistency of these processes as well as recommendations for methodologies and tolerance limits in patient-specific IMRT QA.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            American College of Radiology (ACR) and American Society for Radiation Oncology (ASTRO) Practice Guideline for Intensity-modulated Radiation Therapy (IMRT).

            Intensity-modulated radiation therapy (IMRT) is a complex technique for the delivery of radiation therapy preferentially to target structures while minimizing doses to adjacent normal critical structures. It is widely utilized in the treatment of a variety of clinical indications in radiation oncology, including tumors of the central nervous system, head and neck, breast, prostate, gastrointestinal tract, and gynecologic organs, as well as in situations where previous radiation therapy has been delivered, and has allowed for significant therapeutic advances in many clinical areas. IMRT treatment planning and delivery is a complex process. Safe and reliable delivery of IMRT requires appropriate process design and adherence to quality assurance (QA) standards. A collaborative effort of the American College of Radiology and American Society for Therapeutic Radiation Oncology has produced a practice guideline for IMRT. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist, dosimetrist, and radiation therapist. Factors with respect to the QA of the treatment planning system, treatment-planning process, and treatment-delivery process are discussed, as are issues related to the utilization of volumetric modulated arc therapy. Patient-specific QA procedures are presented. Successful IMRT programs involve integration of many processes: patient selection, patient positioning/immobilization, target definition, treatment plan development, and accurate treatment delivery. Appropriate QA procedures, including patient-specific QA procedures, are essential to ensure quality in an IMRT program and to assure patient safety.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Computed medical imaging. Nobel lecture, Decemberr 8, 1979.

                Bookmark

                Author and article information

                Contributors
                Journal
                Materials Today: Proceedings
                Materials Today: Proceedings
                Elsevier BV
                22147853
                2022
                2022
                : 49
                : 3050-3055
                Article
                10.1016/j.matpr.2020.10.899
                50510e28-e31d-4196-94d9-14a4f74ad3a9
                © 2022

                https://www.elsevier.com/tdm/userlicense/1.0/

                History

                Comments

                Comment on this article