0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Facile and tunable fabrication of Fe3O4/graphene oxide nanocomposites and their application in the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from environmental water samples.

      1 , , , , ,
      Talanta
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          An electrostatic self-assembly approach was employed to prepare Fe(3)O(4)/graphene oxide nanocomposites, and their application in the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from environmental samples was investigated. With the highly hydrophilic graphene oxide sheets and positively charged surface of the Fe(3)O(4) nanoparticles, the nanocomposites were synthesized through electrostatic interaction in aqueous solution. Simultaneously, the different loading amounts of Fe(3)O(4) onto the graphene oxide were easily controlled by changing the proportion of the initial precursors. The identity of the hybrid materials was confirmed using transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy and a vibrating sample magnetometer. Five polycyclic aromatic hydrocarbons were selected as model analytes to validate the extraction performance of the Fe(3)O(4)/GO nanocomposite as a MSPE sorbent. The excellent adsorption property was attributed to the dominant roles of π-π stacking interaction and hydrophobic interaction. After optimizing the conditions, the results indicated that the recoveries of these compounds were in the range of 76.8-103.2%, with relative standard deviations ranging between 1.7% and 11.7%; the limits of detection were in the range of 0.09-0.19 ng mL(-1).

          Related collections

          Author and article information

          Journal
          Talanta
          Talanta
          Elsevier BV
          1873-3573
          0039-9140
          Nov 15 2012
          : 101
          Affiliations
          [1 ] Beijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry, Tsinghua University, Beijing 100084, China.
          Article
          S0039-9140(12)00802-8
          10.1016/j.talanta.2012.09.046
          23158339
          495c3fde-6941-427f-90d9-c3910406c2ba
          History

          Comments

          Comment on this article