9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      An Approach to Evaluate Blurriness in Retinal Images with Vitreous Opacity for Cataract Diagnosis

      research-article
      1 , 1 , * , 2
      Journal of Healthcare Engineering
      Hindawi

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Cataract is one of the leading causes of blindness in the world's population. A method to evaluate blurriness for cataract diagnosis in retinal images with vitreous opacity is proposed in this paper. Three types of features are extracted, which include pixel number of visible structures, mean contrast between vessels and background, and local standard deviation. To avoid the wrong detection of vitreous opacity as retinal structures, a morphological method is proposed to detect and remove such lesions from retinal visible structure segmentation. Based on the extracted features, a decision tree is trained to classify retinal images into five grades of blurriness. The proposed approach was tested using 1355 clinical retinal images, and the accuracies of two-class classification and five-grade grading compared with that of manual grading are 92.8% and 81.1%, respectively. The kappa value between automatic grading and manual grading is 0.74 in five-grade grading, in which both variance and P value are less than 0.001. Experimental results show that the grading difference between automatic grading and manual grading is all within 1 grade, which is much improvement compared with that of other available methods. The proposed grading method provides a universal measure of cataract severity and can facilitate the decision of cataract surgery.

          Related collections

          Most cited references41

          • Record: found
          • Abstract: found
          • Article: not found

          Detection of blood vessels in retinal images using two-dimensional matched filters.

          Blood vessels usually have poor local contrast, and the application of existing edge detection algorithms yield results which are not satisfactory. An operator for feature extraction based on the optical and spatial properties of objects to be recognized is introduced. The gray-level profile of the cross section of a blood vessel is approximated by a Gaussian-shaped curve. The concept of matched filter detection of signals is used to detect piecewise linear segments of blood vessels in these images. Twelve different templates that are used to search for vessel segments along all possible directions are constructed. Various issues related to the implementation of these matched filters are discussed. The results are compared to those obtained with other methods.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Retinal imaging and image analysis.

            Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of blindness in the industrialized world that includes age-related macular degeneration, diabetic retinopathy, and glaucoma, the review is devoted to retinal imaging and image analysis methods and their clinical implications. Methods for 2-D fundus imaging and techniques for 3-D optical coherence tomography (OCT) imaging are reviewed. Special attention is given to quantitative techniques for analysis of fundus photographs with a focus on clinically relevant assessment of retinal vasculature, identification of retinal lesions, assessment of optic nerve head (ONH) shape, building retinal atlases, and to automated methods for population screening for retinal diseases. A separate section is devoted to 3-D analysis of OCT images, describing methods for segmentation and analysis of retinal layers, retinal vasculature, and 2-D/3-D detection of symptomatic exudate-associated derangements, as well as to OCT-based analysis of ONH morphology and shape. Throughout the paper, aspects of image acquisition, image analysis, and clinical relevance are treated together considering their mutually interlinked relationships.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation.

              This paper presents an algorithm based on mathematical morphology and curvature evaluation for the detection of vessel-like patterns in a noisy environment. Such patterns are very common in medical images. Vessel detection is interesting for the computation of parameters related to blood flow. Its tree-like geometry makes it a usable feature for registration between images that can be of a different nature. In order to define vessel-like patterns, segmentation is performed with respect to a precise model. We define a vessel as a bright pattern, piece-wise connected, and locally linear, mathematical morphology is very well adapted to this description, however other patterns fit such a morphological description. In order to differentiate vessels from analogous background patterns, a cross-curvature evaluation is performed. They are separated out as they have a specific Gaussian-like profile whose curvature varies smoothly along the vessel. The detection algorithm that derives directly from this modeling is based on four steps: (1) noise reduction; (2) linear pattern with Gaussian-like profile improvement; (3) cross-curvature evaluation; (4) linear filtering. We present its theoretical background and illustrate it on real images of various natures, then evaluate its robustness and its accuracy with respect to noise.
                Bookmark

                Author and article information

                Journal
                J Healthc Eng
                J Healthc Eng
                JHE
                Journal of Healthcare Engineering
                Hindawi
                2040-2295
                2040-2309
                2017
                26 April 2017
                : 2017
                : 5645498
                Affiliations
                1School of Information and Electronics, Beijing Institute of Technology, Beijing 100081, China
                2Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Beijing 100730, China
                Author notes

                Academic Editor: Fabrice Meriaudeau

                Author information
                http://orcid.org/0000-0002-9665-8266
                http://orcid.org/0000-0002-8720-3374
                Article
                10.1155/2017/5645498
                5424487
                29065620
                4875c8b6-05cb-49c5-8d8f-66fcba62844f
                Copyright © 2017 Li Xiong et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 24 October 2016
                : 22 January 2017
                : 13 February 2017
                Categories
                Research Article

                Comments

                Comment on this article