      Novel highly accelerated real-time CINE-MRI featuring compressed sensing with k-t regularization in comparison to TSENSE segmented and real-time Cine imaging

      abstract
      1 , , 3 , 2 , 2 , 2 , 1 , 1
      Journal of Cardiovascular Magnetic Resonance
      BioMed Central
      16th Annual SCMR Scientific Sessions
      31 January-3 February 2013

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background In patients with breath-holding difficulties or arrhythmia, real-time CINE-MRI is preferred over segmented acquisitions in one breath-hold. However, common real-time sequences require a deteriorating trade-off between spatial and temporal resolution. In the current work, highly accelerated real-time CINE-MRI which features compressed sensing with k t regularization [1] was evaluated against segmented and real-time imaging with TSENSE in healthy volunteers as a potential alternative providing both high spatial and temporal resolution in real time. Methods Sparse and incoherent sampling was implemented in a bSSFP 2D CINE-MRI sequence and a compressed sensing image reconstruction program featuring k-t regularization was provided. Thirteen healthy volunteers (7m/6f, age 43±17y, BMI 24±6.6) underwent CMR imaging on a 1.5T system (MAGNETOM Aera, Siemens AG, Erlangen, Germany). 2-/3-/4-chamber as well as 3 short-axis views were acquired with a fixed temporal resolution of 33 ms but different net acceleration factors (NAF) and acquisition durations (acq) based on the used sequences: (1) segmented TSENSE, NAF 2, (sTSENSE2), acq: 6 heartbeats (2) segmented TSENSE, NAF 4, (sTSENSE4), acq: 3 heartbeats (3) real-time TSENSE, NAF 4, (rtTSENSE4), acq: 1 heartbeat (4) real-time compressed sensing, NAF 10.9, (rtCS11), acq: 1 heartbeat The acquired (reconstructed) voxel sizes were 2.4 x 1.7 x 6 mm3 (1.7 x 1.7 x 6 mm3), except for rtTSENSE4 with 6.0 x 3.0 x 6 mm3 (3.0 x 3.0 x 6mm3). Image reconstruction was performed online. All images were qualitatively assessed by an experienced CMR reader on a five-point Likert scale (5-excellent, 1-non-diagnostic). Scoring was performed with respect to the overall image quality with focus on presence/severity of artifacts and the ability to visually assess global and regional myocardial function. A paired t-test was used to compare differences in image quality between the different sequences. Figure 1 Example images of a short-axis and a 3-chamber view of volunteer 5 from left to right: sTSENSE2; sTSENSE4; rtTSENSE4; rtCS11 Results In all subjects, 2D datasets could be successfully acquired. The mean RR interval was 934±116 ms, three volunteers had sinus arrhythmia or extra systoles. Table 1 illustrates the results of the quality assessment. In terms of quality score, benchmark was set by sTSENSE2 (4.7±0.5). rtCS11 was significantly better than rtTSENSE4 (3.6±0.7 vs. 2.7±0.6, p<0.0001) and comparable to the quality of sTSENSE4 (3.9±0.5, p=0.004). Quality-relevant artifacts were rather noise-related in sTSENSE4 and contour- as well as flow-related in rtCS11. Table 1 Quality assessment sTSENSE2 sTSENSE4 rtTSENSE4 rtCS11 Acq/temporal resolution 6hb/33 ms 3hb/33 ms 1hb/33 ms 1hb/33 ms Spatial Resolution/SLT (mm) 2.4x1.7x6/6 2.4x1.7x6/6 6.0x3.0x3.0/6 2.4x1.7x6/6 Mean overall image quality 4.8±0.5 3.9±0.5 2.7±0.6 3.7±0.7 Comparison with rtCS11 p<0.001 p=0.004 p<0.001 Conclusions As the image quality of rtCS11 was significantly better than in case of real-time TSENSE and close to that of sTSENSE4, the novel method may become a better alternative for the assessment of cardiac function in real time. Further studies in a clinical setting are required to assess the performance in challenging cases. Funding Siemens AG

          Related collections

          Author and article information

          Conference
          J Cardiovasc Magn Reson
          J Cardiovasc Magn Reson
          Journal of Cardiovascular Magnetic Resonance
          BioMed Central
          1097-6647
          1532-429X
          2013
          30 January 2013
          : 15
          : Suppl 1
          : P36
          Affiliations
          [1 ]MR PI, Siemens AG, Erlangen, Germany
          [2 ]SCR, Siemens AG, Princeton, NY, USA
          [3 ]CX CRM, Siemens AG, Erlangen, Germany
          Article
          1532-429X-15-S1-P36
          10.1186/1532-429X-15-S1-P36
          3559967
          4090d355-ae76-4946-9841-5f7f10a4a646
          Copyright ©2013 Schmidt et al; licensee BioMed Central Ltd.

          This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

          16th Annual SCMR Scientific Sessions
          San Francisco, CA, USA
          31 January-3 February 2013
          History
          Categories
          Poster Presentation

          Cardiovascular Medicine
          Cardiovascular Medicine

          Comments

          Comment on this article