          Abstract

          Background

          Iatrogenic perforation of the right ventricle (RV) is a rare but recognized complication of pericardiocentesis. Treatment strategies for RV perforation include surgical repair and percutaneous closure. In this case report, we describe the use of an angio-seal vascular closure device (Terumo Interventional Systems) to seal an iatrogenic RV perforation secondary to incorrect placement of a pericardial drain.

          Case summary

          A 55-year-old female presented with an anterior ST-elevation myocardial infarction. Coronary angiography demonstrated occlusion of the left anterior descending artery. The patient went on to have primary percutaneous coronary intervention and both the left anterior descending and D1 were wired. During kissing balloon inflation, the Sion Blue wire migrated distally in the D1 causing an Ellis type 3 wire tip perforation in the distal D1. Emergency pericardiocentesis was performed however the 8 French (8 Fr) pericardial drain was inadvertently inserted into the RV. It was decided to attempt percutaneous closure with an 8 Fr angio-seal in the catheter lab under echocardiographic and fluoroscopic guidance. Our patient did not demonstrate any recurrence of pericardial effusion on repeat echocardiography over 60 days post-procedure.

          Discussion

          Our patient did not demonstrate any recurrence of pericardial effusion on repeat echocardiography over 60 days post-procedure. We feel that the angio-seal vascular closure device represents an effective, minimally invasive treatment for this rare but potentially catastrophic complication of pericardiocentesis. In this case, the technique spared our patient a sternotomy with its associated morbidity.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: found
          • Article: not found

          Clinical experience with percutaneous left ventricular transapical access for interventions in structural heart defects a safe access and secure exit.

          This study sought to evaluate the safety of percutaneous direct left ventricular access for interventional procedures. Experience with percutaneous access of the left ventricle (LV) for interventional procedures has been limited and associated with a high percentage of major complications. We report our clinical experience with percutaneous direct LV access for interventional procedures. Between March 2008 and December 2010, there were 32 percutaneous transapical punctures in 28 consecutive patients (16 males, mean age 68.2 ± 10.8 years). The delivery sheath sizes ranged from 5- to 12-F. All transapical punctures were successfully performed, and safe closure of the access sites was achieved. Total procedural time was 153.6 ± 49.4 min for procedures converted from conventional approaches to a transapical approach, 129.5 ± 29.6 min for the transapical approach with trans-septal rail support, and 109.3 ± 41.4 min for the planned transapical approach. Fluoroscopy time was 61.3 ± 26.1 min, 29.7 ± 20.8 min, and 27.4 ± 21.4 min, respectively. Fluoroscopy time for closure of mitral paravalvular leaks was reduced by 35%, from 42.6 ± 29.9 min to 27.4 ± 15.6 min. Complications were observed in 2 patients (7.1%). With meticulous planning, transapical puncture is safe. The transapical access provides a more direct approach to the LV targets for intervention and leads to a significant decrease in the procedural and fluoroscopy times. Device closure of the direct LV access site is a reliable and safe method of hemostasis. Placement of a closure device should be considered if sheaths larger than 5-F are used. Although we used this technique only for paravalvular leak and LV pseudoaneurysm closure, it may have application for other percutaneous structural heart interventions. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Pericardiocentesis in cardiac tamponade: indications and practical aspects

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Amplatzer Septal Occluder to treat iatrogenic cardiac perforations.

              Iatrogenic free wall cardiac perforation is a rare but serious complication encountered during percutaneous cardiac procedures, which usually leads to tamponade and death. Septal occluder devices have been developed for sealing intracardiac shunts but may be also used in this emergency setting. We report a small series of five consecutive cases of iatrogenic heart perforations that were treated with implantation of Amplatzer Septal Occluders (ASO). In the first case, iatrogenic left ventricle (LV) perforation occurred during LV biopsy and could be closed up with a 4 mm ASO. In the second case, a 4 mm ASO was used for sealing of a right atrial perforation allocated to Port-a-Cath dislodgment. The third case happened during transseptal puncture for implantation of a TandemHeart bVAD device in a patient suffering cardiogenic shock and was treated by implantation of a 5 mm ASO. The fourth patient was transferred to our facilities for percutaneous closure of an acute post-infarct VSD after anteroseptal myocardial infarction. This procedure was complicated by perforation of the posterolateral free wall and led to the deployment of 12 mm ASO. The last patient suffered from free LV wall perforation during investigation of a severe aortic stenosis and was treated by implantation of 4 mm ASO. All patients were alive after 24 hrs but the last patient died during the in-hospital stay of a right ventricular infarction complicated by multiple organ failure. Percutaneous device occlusion of iatrogenic heart perforation seems to be a safe and efficient method to treat iatrogenic heart perforation. In order to perform this elegant method, it is however imperative not to prematurely withdraw the perforating catheter to maintain access to the hole for closure. Copyright © 2011 Wiley Periodicals, Inc.
                Bookmark

                Author and article information

                Contributors
                Role: Handling Editor
                Role: Editor
                Role: Editor
                Role: Editor
                Role: Editor
                Role: Editor
                Journal
                Eur Heart J Case Rep
                Eur Heart J Case Rep
                ehjcr
                European Heart Journal: Case Reports
                Oxford University Press
                2514-2119
                October 2020
                21 August 2020
                21 August 2020
                : 4
                : 5
                : 1-4
                Affiliations
                Department of Cardiology, St James’s Hospital , Kilmainham, Dublin 8, Ireland
                Author notes
                Corresponding author. Tel: +353862077762, Email: jjcoughl@ 123456gmail.com
                Author information
                http://orcid.org/0000-0001-6086-3279
                http://orcid.org/0000-0001-6977-2197
                Article
                ytaa258
                10.1093/ehjcr/ytaa258
                7649447
                3ab9effe-0ff4-402a-8177-5c50f19c8743
                © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com

                History
                : 10 April 2020
                : 04 May 2020
                : 13 July 2020
                Page count
                Pages: 4
                Categories
                Case Reports
                Coronary heart disease (incl. Cardiac Intervention)
                AcademicSubjects/MED00200

                case report,pericardial effusion,angio-seal,coronary perforation,right ventricular,perforation

                Comments

                Comment on this article