      Comparative Cost Analysis of Four Different Computer-Assisted Technologies to Implant a Total Knee Arthroplasty over Conventional Instrumentation

      , , , , ,
      Journal of Personalized Medicine
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Several computer-assisted technologies, such as navigation and robotics, have been introduced to Total Knee Arthroplasty (TKA) in order to increase surgical precision and reduce complications. However, these technologies are often criticized due to the increased costs and effort associated with them; however, comparative data are missing. The aim of the present study was to evaluate differences in intraoperative workflows and the related perioperative cost-profiles of four current computer-assisted technologies, used to implant a TKA, in order to gain a comparison to conventional instrumentation. For the cost analysis, additional preoperative imaging and instruments, increased operating room (OR) and planning-time, and expenditures for technical support of the equipment and disposals were calculated, in comparison to conventional TKA, for (1) standard computer-navigation, (2) patient specific instruments (PSI), (3) image-based robotic assistance, and (4) imageless robotic assistance. Workflows at four expert centers which use these technologies were reviewed by an independent observer. The total cost calculation was based on a 125 TKA per year unit in Switzerland. Computer-navigation resulted in 14 min (+23%) increased surgery time and, overall, USD 650 in additional costs. PSI technology saved 5 min (8%) OR time but it created USD 1520 in expenditures for imaging and disposals. The image-based robotic system was the most expensive technology; it created overall additional costs of USD 2600, which predominately resulted from technical support, disposals, the CT-Scan, and 14 min of increased OR time. The imageless robotic assistance resulted in the largest increase in OR-time, as it resulted in an additional 25 min (+42%) on average. Overall, additional costs of USD 1530 were calculated. Every one of the assistive technologies in this study increased the total cost of TKA when compared to a conventional technique, and the most important variables, related to cost, were technical support and additional disposables. The longer surgical times and additional surgical trays required for the techniques had a marginal effect on overall costs. This comparative cost analysis gives valuable information for future efforts to calculate the real costs of these technologies and the subsequent return on investment of each technique.

          Related collections

          Most cited references24

          • Record: found
          • Abstract: not found
          • Article: not found

          Current Role of Computer Navigation in Total Knee Arthroplasty

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Efficacy of Patient-Specific Instruments in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.

            Patient-specific instrumentation (PSI) was introduced with the aim of making the procedure of total knee arthroplasty more accurate and efficient. The purpose of this study was to compare PSI and standard instrumentation in total knee arthroplasty with regard to radiographic and clinical outcomes as well as operative time and blood loss.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Robotic-assisted total knee arthroplasty is comparable to conventional total knee arthroplasty: a meta-analysis and systematic review.

              Total knee arthroplasty (TKA) is a successful procedure in managing end-stage arthritis when non-operative treatments fail. New technologies such as robotic TKA (rTKA) have been developed to improve the accuracy of prosthesis implantation. While short-term cohort studies on rTKA have shown excellent results, the evidence comparing between rTKA and conventional TKA (cTKA) is not yet well established. This meta-analysis aims to compare the efficacy and safety of rTKA versus cTKA in terms of clinical outcomes, radiographic results, complications, peri-operative parameters and costs.
                Bookmark

                Author and article information

                Journal
                JPMOB3
                Journal of Personalized Medicine
                JPM
                MDPI AG
                2075-4426
                February 2022
                January 30 2022
                : 12
                : 2
                : 184
                Article
                10.3390/jpm12020184
                35207672
                21bad781-6d6b-4ba4-a4e0-dbfca24937b7
                © 2022

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content155

                Cited by11

                Most referenced authors228