30
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Accuracy of the use of triaxial accelerometry for measuring daily activity as a predictor of daily maintenance energy requirement in healthy adult Labrador Retrievers.

      American journal of veterinary research
      Pedigree, methods, Animals, Linear Models, Monitoring, Physiologic, Energy Metabolism, instrumentation, veterinary, Motor Activity, physiology, Dogs, Time Factors, Female, Male

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To determine accuracy of the use of triaxial accelerometry for measuring daily activity as a predictor of maintenance energy requirement (MER) in healthy adult Labrador Retrievers. 10 healthy adult Labrador Retrievers. Dogs wore an accelerometer for two 2-week periods, with data on daily activity successfully collected for 24 to 26 days. These data, along with body weight, were used as independent variables in a multiple linear regression model to predict the dependent variable of daily MER. The predictive accuracy of the model was compared with that of a model that excluded activity. Dietary energy intake at a stated amount of body weight stability was used as an equivalent measure of MER in these analyses. The multiple linear regression model that included body weight and daily activity as independent variables could be used to predict observed MER with a mean absolute error of 63.5 kcal and an SE of estimation of 94.3 kcal. Removing activity from the model reduced the predictive accuracy to a mean absolute error of 129.8 kcal and an SE of estimation of 165.4 kcal. Use of triaxial accelerometers to provide an independent variable of daily activity yielded a marked improvement in predictive accuracy of the regression model, compared with that for a model that used only body weight. Improved accuracy in estimations of MER could be made for each dog if an accelerometer was used to record its daily activity.

          Related collections

          Author and article information

          Journal
          21879971
          10.2460/ajvr.72.9.1151

          Chemistry
          Pedigree,methods,Animals,Linear Models,Monitoring, Physiologic,Energy Metabolism,instrumentation,veterinary,Motor Activity,physiology,Dogs,Time Factors,Female,Male

          Comments

          Comment on this article