      Polytetrafluoroethylene graft calcification in patients with surgically repaired congenital heart disease: evaluation using multidetector-row computed tomography.

      American Heart Journal
      Adolescent, Adult, Blood Vessel Prosthesis, adverse effects, Calcinosis, etiology, radiography, Child, Child, Preschool, Equipment Failure Analysis, methods, Female, Fontan Procedure, Heart Defects, Congenital, therapy, Heart Valve Prosthesis, Heart, Artificial, Humans, Male, Phantoms, Imaging, Polytetrafluoroethylene, Tomography, X-Ray Computed, instrumentation, Ventricular Outflow Obstruction, surgery

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Noninvasive determination of calcified prosthetic polytetrafluoroethylene (PTFE) is important in improving risk stratification. The purpose of this study is to assess the feasibility of multidetector-row computed tomography (MDCT) for the evaluation of PTFE calcification in patients with surgically repaired congenital heart disease and to evaluate the development and characteristics of calcification for specific surgical procedures. Seventy-six implanted PTFE grafts in 47 patients were evaluated by MDCT (Aquillion 16, Toshiba Corporation, Tokyo, Japan). Explanted PTFE grafts were evaluated histologically in 4 patients who underwent reoperation after MDCT scans. Calcification of prosthetic PTFE was detected in 5 of 29 cases (17%) for ventricular septal defect (VSD) patches, 26 of 32 (81%) for right ventricular outflow tract (RVOT) prosthesis, 2 of 8 (25%) for atrial septal patches of the Fontan procedure, and 7 of 7 (100%) for extracardiac conduits of total cavopulmonary connection. The CT attenuation of PTFE revealed significantly different values for VSD patches (114 +/- 61 Hounsfield units [HU]), RVOT prosthesis (243 +/- 132 HU), atrial septal patches (163 +/- 161 HU), and extracardiac conduits (230 +/- 29 HU) (P < .0001). The CT density value of VSD patches was significantly lower than those of RVOT grafts and extracardiac conduits (P < .05). The MDCT findings were consistent with histologic analysis in the evaluation of calcification. This study demonstrates that MDCT enables the evaluation of prosthetic PTFE graft calcification; PTFE grafts in 4 different implantation sites demonstrated distinctive features and the prevalence of calcification.

          Related collections

          Author and article information

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content386

          Cited by12