2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Rate of Stenotic Bicuspid Aortic Valve Aortic Dilatation After Aortic Valve Replacement, Calculated Using a 3-Dimensional Reconstruction Tool.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Progression of asymmetric dilated aorta associated with bicuspid aortic valve (BAV) is difficult to evaluate conventionally. The aim of the study was to calculate the rate of progression of the dilated BAV aorta after aortic valve replacement (AVR) using a 3-dimensional (3-D) reconstruction tool.Methods and Results:Fourteen stenotic BAV and 14 stenotic tricuspid aortic valve (TAV) patients with mildly dilated ascending aorta were reviewed. A patient-specific 3-D aortic model was reconstructed from preoperative and postoperative computed tomography data (BAV, 2.5±1.9 years after AVR; TAV, 2.2±1.8 years after AVR). Aortic diameter, including the longest and shortest, was measured on the maximum perpendicular cross-section tangential to the 3-D centerline of the reconstructed model. The longest diameter was defined as that passing through the distal point of the greater curvature of the aorta. The shortest diameter was defined as perpendicular to the longest. The progression rates were compared between the BAV and TAV groups. The progression rate of ascending aortic diameter was greater for BAV (longest diameter, 1.02±1.03 vs. -0.075±0.78 mm/year, P<0.001; shortest diameter, 0.41±0.62 vs. -0.016±0.59 mm/year, P=0.003). The longest diameter of the proximal arch also grew more rapidly in the BAV group (P<0.001).

          Related collections

          Author and article information

          Journal
          Circ J
          Circulation journal : official journal of the Japanese Circulation Society
          Japanese Circulation Society
          1347-4820
          1346-9843
          Jul 25 2017
          : 81
          : 8
          Affiliations
          [1 ] Department of Cardiovascular Surgery, Hirosaki University, Graduate School of Medicine.
          Article
          10.1253/circj.CJ-16-0974
          28367857
          13e63c7f-7105-42ca-97b5-52bf31a251a6
          History

          Aortic valve,Asymmetric aneurysm,Reconstruction tool

          Comments

          Comment on this article