38
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Influence of Orthotropy on Biomechanics of Peri-Implant Bone in Complete Mandible Model with Full Dentition

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective. The study was to investigate the impact of orthotropic material on the biomechanics of dental implant, based on a detailed mandible with high geometric and mechanical similarity. Materials and Methods. Multiple data sources were used to elaborate detailed biological structures and implant CAD models. In addition, an extended orthotropic material assignment methodology based on harmonic fields was used to handle the alveolar ridge region to generate compatible orthotropic fields. The influence of orthotropic material was compared with the commonly used isotropic model and simplified orthotropic model. Results. The simulation results showed that the values of stress and strain on the implant-bone interface almost increased in the orthotropic model compared to the isotropic case, especially for the cancellous bone. However, the local stress concentration was more obvious in the isotropic case compared to that in orthotropic case. The simple orthotropic model revealed irregular stress and strain distribution, compared to the isotropic model and the real orthotropic model. The influence of orthotropy was little on the implant, periodontal ligament, tooth enamel, and dentin. Conclusion. The orthotropic material has significant effect on stress and strain of implant-bone interface in the mandible, compared with the isotropic simulation. Real orthotropic mechanical properties of mandible should be emphasized in biomechanical studies of dental implants.

          Related collections

          Most cited references30

          • Record: found
          • Abstract: found
          • Article: not found

          In vivo bone response to biomechanical loading at the bone/dental-implant interface.

          Since dental implants must withstand relatively large forces and moments in function, a better understanding of in vivo bone response to loading would aid implant design. The following topics are essential in this problem. (1) Theoretical models and experimental data are available for understanding implant loading as an aid to case planning. (2) At least for several months after surgery, bone healing in gaps between implant and bone as well as in pre-existing damaged bone will determine interface structure and properties. The ongoing healing creates a complicated environment. (3) Recent studies reveal that an interfacial cement line exists between the implant surface and bone for titanium and hydroxyapatite (HA). Since cement lines in normal bone have been identified as weak interfaces, a cement line at a bone-biomaterial interface may also be a weak point. Indeed, data on interfacial shear and tensile "bond" strengths are consistent with this idea. (4) Excessive interfacial micromotion early after implantation interferes with local bone healing and predisposes to a fibrous tissue interface instead of osseointegration. (5) Large strains can damage bone. For implants that have healed in situ for several months before being loaded, data support the hypothesis that interfacial overload occurs if the strains are excessive in interfacial bone. While bone "adaptation" to loading is a long-standing concept in bone physiology, researchers may sometimes be too willing to accept this paradigm as an exclusive explanation of in vivo tissue responses during experiments, while overlooking confounding variables, alternative (non-mechanical) explanations, and the possibility that different types of bone (e.g., woven bone, Haversian bone, plexiform bone) may have different sensitivities to loading under healing vs. quiescent conditions.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Modern human molar enamel thickness and enamel-dentine junction shape.

            This study examines cross-sections of molar crowns in a diverse modern human sample to quantify variation in enamel thickness and enamel-dentine junction (EDJ) shape. Histological sections were generated from molars sectioned buccolingually across mesial cusps. Enamel cap area, dentine area, EDJ length, and bi-cervical diameter were measured on micrographs using a digitizing tablet. Nine landmarks along the EDJ were defined, and X and Y coordinates were digitized in order to quantify EDJ shape. Upper molars show greater values for the components of enamel thickness, leading to significantly greater average enamel thickness than in lower molars. Average enamel thickness increased significantly from M1 to M3 in both molar rows, due to significantly increasing enamel cap area in upper molars, and decreasing dentine area in lower molars. Differences in EDJ shape were found among maxillary molars in combined and individual populations. Sex differences were also found; males showed significantly greater dentine area, EDJ length, and bi-cervical diameters in certain tooth types, which resulted in females having significantly thicker average enamel. Differences in enamel thickness and EDJ shape within molars were also found among populations, although few consistent trends were evident. This study demonstrates that enamel thickness and EDJ shape vary among molars, between sexes, and among populations; these factors must be considered in the categorization and comparison of ape and human molars, particularly when isolated teeth or fossil taxa are included. Human relative enamel thickness encompasses most values reported for fossil apes and humans, suggesting limited taxonomic value when considered alone.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Variations in cortical material properties throughout the human dentate mandible.

              Material properties and their variations in individual bone organs are important for understanding bone adaptation and quality at a tissue level, and are essential for accurate mechanical models. Yet material property variations have received little systematic study. Like all other material property studies in individual bone organs, studies of the human mandible are limited by a low number of both specimens and sampled regions. The aims of this study were to determine: 1) regional variability in mandibular material properties, 2) the effect of this variability on the modeling of mandibular function, and 3) the relationship of this variability to mandibular structure and function. We removed 31 samples on both facial and lingual cortices of 10 fresh adult dentate mandibles, measured cortical thickness and density, determined the directions of maximum stiffness with a pulse transmission ultrasonic technique, and calculated elastic properties from measured ultrasonic velocities. Results showed that each of these elastic properties in the dentate human mandible demonstrates unique regional variation. The direction of maximum stiffness was near parallel to the occlusal plane within the corpus. On the facial ramus, the direction of maximum stiffness was more vertically oriented. Several sites in the mandible did not show a consistent direction of maximum stiffness among specimens, although all specimens exhibited significant orthotropy. Mandibular cortical thickness varied significantly (P < 0.001) between sites, and decreased from 3.7 mm (SD = 0.9) anteriorly to 1.4 mm posteriorly (SD = 0.1). The cortical plate was also significantly thicker (P < 0.003) on the facial side than on the lingual side. Bone was 50-100% stiffer in the longitudinal direction (E(3), 20-30 GPa) than in the circumferential or tangential directions (E(2) or E(1); P < 0.001). The results suggest that material properties and directional variations have an important impact on mandibular mechanics. The accuracy of stresses calculated from strains and average material properties varies regionally, depending on variations in the direction of maximum stiffness and anisotropy. Stresses in some parts of the mandible can be more accurately calculated than in other regions. Limited evidence suggests that the orientations and anisotropies of cortical elastic properties correspond with features of cortical bone microstructure, although the relationship with functional stresses and strains is not clear. Copyright 2003 Wiley-Liss, Inc.
                Bookmark

                Author and article information

                Journal
                Biomed Res Int
                Biomed Res Int
                BMRI
                BioMed Research International
                Hindawi Publishing Corporation
                2314-6133
                2314-6141
                2014
                3 November 2014
                : 2014
                : 709398
                Affiliations
                1Department of Stomatology, First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325000, China
                2School of Information Science and Engineering, Central South University, Changsha 410083, China
                3Department of Oral and Maxillofacial Surgery, First Affiliated Hospital of Zhejiang University, Hangzhou 310006, China
                Author notes
                *Sheng-Hui Liao: lsh@ 123456csu.edu.cn

                Academic Editor: Li Wu Zheng

                Author information
                http://orcid.org/0000-0002-8872-2117
                Article
                10.1155/2014/709398
                4235237
                054cc490-f613-4010-87df-a740027c5595
                Copyright © 2014 Xi Ding et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 29 July 2014
                : 1 September 2014
                : 1 September 2014
                Categories
                Research Article

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content203

                Cited by4

                Most referenced authors257