      Development of a high-performance label-free electrochemical immunosensor for early cancer diagnosis using anti-CEA/Ag-MOF/GO/GCE nanocomposite.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In order to detect carcinoembryonic antigen (CEA) as a tumor marker in lung cancer for early cancer diagnosis, this study aimed to develop a label-free electrochemical immunosensor based on the immobilization of an Anti-CEA antibody on a metal-organic framework (MOF)-graphene oxide nanocomposite modified glassy carbon electrode (Anti-CEA/Ag-MOF/GO/GCE). Ag-MOF/GO nanocomposite was prepared on the GCE surface using the ultrasonic irradiation method, and Anti-CEA antibody was subsequently immobilized on the surface. Analysis of the crystal structure and morphology of the modified electrode using FE-SEM and XRD revealed that the correct combination of GO nanosheets and Ag-MOF nanoparticles produced a high surface area to trap the antibodies. Electrochemical tests utilizing the CV and DPV methods revealed that the immunosensor's sensitivity, stability, and selectivity were improved by Anti-CEA/Ag-MOF/GO/GCE. Results showed that, with a detection limit of 0.005 ng/mL, the change in the reduction peak current was inversely correlated with the logarithm concentration of CEA in the range of 10-3 to 5000 ng/mL. The suggested CEA immunosensor's applicability in a human serum sample was investigated, and findings of analytical studies via standard addition technique for both ELISA and DPV assays revealed that significant agreement existed between the outcomes of the two assays. Additionally, the recoveries ranged from 99.00% to 99.25%, and all relative standard deviations (RSDs) for the sample detections were below 5.01%, indicating satisfactory accuracy in results measured with the proposed CEA immunosensor, indicating that the prepared CEA immunosensor in this study can be used in clinical applications and human fluids.

          Related collections

          Author and article information

          Journal
          Environ Res
          Environmental research
          Elsevier BV
          1096-0953
          0013-9351
          Dec 01 2023
          : 238
          : Pt 2
          Affiliations
          [1 ] Department of Nephrology, Affiliated Hospital of Youjiang Medical University for Nationalities, Guangxi, 533000, China.
          [2 ] Center for Systemic Inflammation Research (CSIR), School of Preclinical Medicine, Youjiang Medical University for Nationalities, Guangxi, 533000, China.
          [3 ] Department of Molecular and Cell Biology, Faculty of Basic Sciences, University of Mazandaran, Babolsar, Iran. Electronic address: Parnianamanii1@gmail.com.
          Article
          S0013-9351(23)01982-5
          10.1016/j.envres.2023.117178
          37734580
          02fc7c98-b3b5-476b-af3f-538dc50c580c
          History

          Electrochemical immunosensor,Carcinoembryonic antigen,Ag-MOF,Graphene oxide,Nanocomposite

          Comments

          Comment on this article