      MRI and CBCT image registration of temporomandibular joint: a systematic review

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          The purpose of the present review is to systematically and critically analyze the available literature regarding the importance, applicability, and practicality of (MRI), computerized tomography (CT) or cone-beam CT (CBCT) image registration for TMJ anatomy and assessment.

          Data sources

          A systematic search of 4 databases; MEDLINE, EMBASE, EBM reviews and Scopus, was conducted by 2 reviewers. An additional manual search of the bibliography was performed.

          Inclusion criteria

          All articles discussing the magnetic resonance imaging MRI and CT or CBCT image registration for temporomandibular joint (TMJ) visualization or assessment were included.

          Results and included articles’ characteristics

          Only 3 articles satisfied the inclusion criteria. All included articles were published within the last 7 years. Two articles described MRI to CT multimodality image registration as a complementary tool to visualize TMJ. Both articles used images of one patient only to introduce the complementary concept of MRI-CT fused image. One article assessed the reliability of using MRI-CBCT registration to evaluate the TMJ disc position and osseous pathology for 10 temporomandibular disorder (TMD) patients.

          Conclusion

          There are very limited studies of MRI-CT/CBCT registration to reach a conclusion regarding its accuracy or clinical use in the temporomandibular joints.

          Electronic supplementary material

          The online version of this article (doi:10.1186/s40463-016-0144-4) contains supplementary material, which is available to authorized users.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: not found
          • Article: not found

          Medical image matching-a review with classification

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Superimposition of 3D cone-beam CT models of orthognathic surgery patients.

            To evaluate the registration of 3D models from cone-beam CT (CBCT) images taken before and after orthognathic surgery for the assessment of mandibular anatomy and position. CBCT scans were taken before and after orthognathic surgery for ten patients with various malocclusions undergoing maxillary surgery only. 3D models were constructed from the CBCT images utilizing semi-automatic segmentation and manual editing. The cranial base was used to register 3D models of pre- and post-surgery scans (1 week). After registration, a novel tool allowed the visual and quantitative assessment of post-operative changes via 2D overlays of superimposed models and 3D coloured displacement maps. 3D changes in mandibular rami position after surgical procedures were clearly illustrated by the 3D colour-coded maps. The average displacement of all surfaces was 0.77 mm (SD=0.17 mm), at the posterior border 0.78 mm (SD=0.25 mm), and at the condyle 0.70 mm (SD=0.07 mm). These displacements were close to the image spatial resolution of 0.60 mm. The average interobserver differences were negligible. The range of the interobserver errors for the average of all mandibular rami surface distances was 0.02 mm (SD=0.01 mm). Our results suggest this method provides a valid and reproducible assessment of craniofacial structures for patients undergoing orthognathic surgery. This technique may be used to identify different patterns of ramus and condylar remodelling following orthognathic surgery.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography.

              Cone beam computed tomography (CBCT) is making headway into imaging for orthodontics. The purpose of this study was to define CBCT multi-planar reformatted projections for temporomandibular joint (TMJ) examination and compare the accuracy of linear measurements of the TMJ and related structures from these projections with similar measurements made with conventional cephalograms and with the anatomic truth. Linear dimensions between 11 anatomical sites were measured with a digital caliper to assess the anatomic truth for 25 dry human skulls. The skulls were imaged with iCAT (Xoran Technologies, Ann Arbor, Mich/Imaging Sciences International, Hatfield, Pa) CBCT, and cephalograms were made in all 3 orthogonal planes (lateral cephalometric [LC], posteroanterior [PA], and submentovertex [SMV]) acquired with photostimulable phosphor plates. Linear measurements were made on 7 custom CBCT reconstructions and the digital cephalograms. Modality means and the natural log of the standard deviations were compared post hoc against the actual dimensions by using analysis of variance with the Dunnett t test. Significance was set at P < .05. All CBCT measurements were accurate; however, 3 of 5 LC measurements, 4 of 5 PA measurements, and 4 of 6 SMV measurements varied significantly from the truth. Intraobserver CBCT measurements were highly reliable compared with anatomic truth and significantly more reliable than measurements made from LC, PA, and SMV images. Custom oblique multi-planar reformatted reconstructions with iCAT CBCT provide accurate and reliable linear measurements of mandibular and TMJ dimensions.
                Bookmark

                Author and article information

                Contributors
                m.alsaleh@ualberta.ca
                Journal
                J Otolaryngol Head Neck Surg
                J Otolaryngol Head Neck Surg
                Journal of Otolaryngology - Head & Neck Surgery
                BioMed Central (London )
                1916-0208
                1916-0216
                10 May 2016
                10 May 2016
                2016
                : 45
                : 30
                Affiliations
                [ ]Department of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Canada
                [ ]Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
                [ ]Department of Radiology and Diagnostic Imaging, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Canada
                Article
                144
                10.1186/s40463-016-0144-4
                4863319
                27164975
                01ce7566-d89f-4608-8388-b25af51489b5
                © Al-Saleh et al. 2016

                Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 29 February 2016
                : 5 May 2016
                Funding
                Funded by: Funding for Dentistry
                Award ID: 2015-01
                Award Recipient :
                Categories
                Review
                Custom metadata
                © The Author(s) 2016

                multimodality,registration,mri,cbct,ct,tmj,tmj disc
                multimodality, registration, mri, cbct, ct, tmj, tmj disc

                Comments

                Comment on this article