26
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Comparative evaluation of antimicrobial effects of Er:YAG, diode, and CO₂ lasers on titanium discs: an experimental study.

      Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons
      Acid Etching, Dental, methods, Bacterial Load, radiation effects, Bacteriological Techniques, Decontamination, Dental Etching, Dental Materials, Humans, Lasers, Gas, therapeutic use, Lasers, Semiconductor, Lasers, Solid-State, Materials Testing, Optical Fibers, Radiation Dosage, Staphylococcus aureus, Surface Properties, Time Factors, Titanium

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This study examined carbon dioxide (CO(2); 10,600 nm), diode (808 nm), and erbium (Er):yttrium-aluminum-garnet (YAG; 2,940 nm) laser applications on Staphylococcus aureus contaminated, sandblasted, large-grit, acid-etched surface titanium discs and performed a comparative evaluation of the obtained bactericidal effects and the applicability of these effects in clinical practice. This study was carried out in 5 main groups: Er:YAG laser in very short pulse (VSP) emission mode, Er:YAG laser in short pulse (SP) emission mode, diode laser with a 320-nm fiber optic diode laser with an R24-B handpiece, and CO(2) laser. After laser irradiation, dilutions were spread on sheep blood agar plates and, after an incubation period of 24 hours, colony-forming units were counted and compared with the control group, and the bactericidal activity was assessed in relation to the colony counts. The CO(2) laser eliminated 100% of the bacteria at 6 W, 20 Hz, and a 10-ms exposure time/pulse with a 10-second application period (0.8-mm spot size). The continuous-wave diode laser eliminated 97% of the bacteria at 1 W using a 10-second application with a 320-μm optic fiber, 100% of the bacteria were killed with a 1-W, 10-second continuous-wave application with an R14-B handpiece. The Er:YAG laser eliminated 100% of the bacteria at 90 mJ and 10 Hz using a 10-second application in a superpulse mode (300-ms exposure time/pulse). The Er:YAG laser also eliminated 99% to 100% of the bacteria in VSP mode at 90 mJ and 10 Hz with a 10-second application. The results of this study show that a complete, or near complete, elimination of surface bacteria on titanium surfaces can be accomplished in vitro using a CO(2), diode, or Er:YAG laser as long as appropriate parameters are used. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article