59
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Evaluation of Mental Foramen with Cone Beam Computed Tomography: A Systematic Review of Literature

      1 , 2 , 1 , 2 , 2 , 3 , 1
      Radiology Research and Practice
      Hindawi Limited

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose. The aim of this systematic review is to assess whether the anatomy of mental foramen is precisely evaluable with cone beam computed tomography (CBCT) before implantation in humans. Methods. A systematic review was carried out to evaluate the anatomy of mental foramen (size, position, symmetry, anterior loop, and accessory mental foramen or multiple mental foramina). According to Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, an electronic search of three databases (Medline, Web of Science, and Cochrane Library) was undertaken until June 2020 and was supplemented by manual searching. Two reviewers will independently perform the processes of study inclusion, data extraction, and quality assessment. Systematic reviews, studies about children, and case reports were excluded. Only studies using CBCT to do preoperative evaluation were selected. Results. From 728 potentially eligible articles, 72 were included in the qualitative analysis and quantitative synthesis. This systematic review provided an assessment of the anatomy of the mental foramen. The mental foramen was located mostly between the two premolars (between 50.4% and 61.95%) or apically to the second premolar (from 50.3% to 57.9%). The mean diameter of the mental foramen was bigger in males than in females; the difference between them could reach 0.62 mm. The anterior loop seemed to be longer in males (between 0.87 ± 1.81 and 7.25 ± 2.02 mm) than in females (between 0.81 ± 1.18 and 6.52 ± 1.63 mm) and with the presence of teeth (from 0.91 ± 1.18 to 2.55 ± 1.28 for dentate people and from 0.25 ± 0.61 to 2.40 ± 0.88 mm for edentate population). The anterior loop and the accessory mental foramina were detected more frequently with CBCT than panoramic X-ray: only between 0.0 and 48.6% AMFs detected with CBCT were also seen with panoramic images. Clinical Significance. The mental foramen (MF) is an important landmark for local anesthesia and surgical and implantology procedures. Its location, morphology, and anatomical variations need to be considered to avoid mental nerve injury. The aim of this review is to evaluate the mental foramen using CBCT through a systematic literature review to improve knowledge of this complex area for the clinician.

          Related collections

          Most cited references95

          • Record: found
          • Abstract: not found
          • Article: not found

          A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review.

            The mental foramen is a strategically important landmark during osteotomy procedures. Its location and the possibility that an anterior loop of the mental nerve may be present mesial to the mental foramen needs to be considered before implant surgery to avoid mental nerve injury. Articles that addressed the position, number, and size of the mental foramen, mental nerve anatomy, and consequences of nerve damage were evaluated for information pertinent to clinicians performing implant dentistry. The mental foramen may be oval or round and is usually located apical to the second mandibular premolar or between apices of the premolars. However, its location can vary from the mandibular canine to the first molar. The foramen may not appear on conventional radiographs, and linear measurements need to be adjusted to account for radiographic distortion. Computerized tomography (CT) scans are more accurate for detecting the mental foramen than conventional radiographs. There are discrepancies between studies regarding the prevalence and length of the loop of the mental nerve mesial to the mental foramen. Furthermore, investigations that compared radiographic and cadaveric dissection data with respect to identifying the anterior loop reported that radiographic assessments result in a high percentage of false-positive and -negatives findings. Sensory dysfunction due to nerve damage in the foraminal area can occur if the inferior alveolar or mental nerve is damaged during preparation of an osteotomy. To avoid nerve injury during surgery in the foraminal area, guidelines were developed based on the literature with respect to verifying the position of the mental foramen and validating the presence of an anterior loop of the mental nerve. These guidelines included leaving a 2 mm zone of safety between an implant and the coronal aspect of the nerve; observation of the inferior alveolar nerve and mental foramen on panoramic and periapical films prior to implant placement; use of CT scans when these techniques do not provide clarity with respect to the position of the nerve; surgical corroboration of the mental foramen's position when an anterior loop of the mental foramen is suspected of being present or if it is unclear how much bone is present coronal to the foramen to establish a zone of safety (in millimeters) for implant placement; once a safety zone is identified, implants can be placed anterior to, posterior to, or above the mental foramen; and prior to placing an implant anterior to the mental foramen that is deeper than the safety zone, the foramen must be probed to exclude the possibility that an anterior loop is present. In general, altered lip sensations are preventable if the mental foramen is located and this knowledge is employed when performing surgical procedures in the foraminal area.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Development of a compact computed tomographic apparatus for dental use

                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                Journal
                Radiology Research and Practice
                Radiology Research and Practice
                Hindawi Limited
                2090-195X
                2090-1941
                January 6 2021
                January 6 2021
                : 2021
                : 1-10
                Affiliations
                [1 ]Oral and Maxillofacial Radiology, Dentistry Department, University Health Centre, University of Nantes, Orvault, France
                [2 ]Private Practice, 34 Rue Jules Verne, 44700 Orvault, France
                [3 ]Oral Implantology, Dentistry Department, University Health Centre, University of Nantes, Nantes, France
                Article
                10.1155/2021/8897275
                c8d6b4d2-e72a-4fa8-b11e-f01a75ca3224
                © 2021

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content543

                Cited by17

                Most referenced authors895