311
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          As the human genome is decoded and its involvement in diseases is being revealed through postgenome research, increased adoption of genetic testing is expected. Critical to such testing methods is the ease of implementation and comprehensible presentation of amplification results. Loop-mediated isothermal amplification (LAMP) is a simple, rapid, specific and cost-effective nucleic acid amplification method when compared to PCR, nucleic acid sequence-based amplification, self-sustained sequence replication and strand displacement amplification. This protocol details an improved simple visual detection system for the results of the LAMP reaction. In LAMP, a large amount of DNA is synthesized, yielding a large pyrophosphate ion by-product. Pyrophosphate ion combines with divalent metallic ion to form an insoluble salt. Adding manganous ion and calcein, a fluorescent metal indicator, to the reaction solution allows a visualization of substantial alteration of the fluorescence during the one-step amplification reaction, which takes 30-60 min. As the signal recognition is highly sensitive, this system enables visual discrimination of results without costly specialized equipment. This detection method should be helpful in basic research on medicine and pharmacy, environmental hygiene, point-of-care testing and more.

          Related collections

          Author and article information

          Journal
          Nat Protoc
          Nature protocols
          Springer Science and Business Media LLC
          1750-2799
          1750-2799
          2008
          : 3
          : 5
          Affiliations
          [1 ] Eiken Chemical Co., Ltd., Biochemical Research Laboratory, 1381-3 Shimoishigami, Ohtawara, Tochigi 324-0036, Japan. norihiro_tomita@eiken.co.jp
          Article
          nprot.2008.57
          10.1038/nprot.2008.57
          18451795
          f7a27f1e-ffcf-4434-822a-246cb66fb4fa
          History

          Comments

          Comment on this article