14
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Relationship of Effective Circulating Volume with Sublingual Red Blood Cell Velocity and Microvessel Pressure Difference: A Clinical Investigation and Computational Fluid Dynamics Modeling

      ,
      Journal of Clinical Medicine
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The characteristics of physiologic hemodynamic coherence are not well-investigated. We examined the physiological relationship between circulating blood volume, sublingual microcirculatory perfusion, and tissue oxygenation in anesthetized individuals with steady-state physiology. We assessed the correlation of mean circulatory filling pressure analogue (Pmca) with sublingual microcirculatory perfusion and red blood cell (RBC) velocity using SDF+ imaging and a modified optical flow-based algorithm. We also reconstructed the 2D microvessels and applied computational fluid dynamics (CFD) to evaluate the correlation of Pmca and RBC velocity with the obtained pressure and velocity fields in microvessels from CFD (pressure difference, (Δp)). Twenty adults with a median age of 39.5 years (IQR 35.5–44.5) were included in the study. Sublingual velocity distributions were similar and followed a log-normal distribution. A constant Pmca value of 14 mmHg was observed in all individuals with sublingual RBC velocity 6–24 μm s−1, while a Pmca < 14 mmHg was observed in those with RBC velocity > 24 μm s−1. When Pmca ranged between 11 mmHg and 15 mmHg, Δp fluctuated between 0.02 Pa and 0.1 Pa. In conclusion, the intact regulatory mechanisms maintain a physiological coupling between systemic hemodynamics, sublingual microcirculatory perfusion, and tissue oxygenation when Pmca is 14 mmHg.

          Related collections

          Most cited references58

          • Record: found
          • Abstract: found
          • Article: not found

          STROCSS 2019 Guideline: Strengthening the reporting of cohort studies in surgery

          The STROCSS guideline was developed in 2017 to improve the reporting quality of observational studies in surgery. Building on its impact and usefulness, we sought to update the guidelines two years after its publication.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found

            Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine

            Hand-held vital microscopes (HVMs) were introduced to observe sublingual microcirculatory alterations at the bedside in different shock states in critically ill patients. This consensus aims to provide clinicians with guidelines for practical use and interpretation of the sublingual microcirculation. Furthermore, it aims to promote the integration of routine application of HVM microcirculatory monitoring in conventional hemodynamic monitoring of systemic hemodynamic variables.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Defining Physiological Normoxia for Improved Translation of Cell Physiology to Animal Models and Humans.

              The extensive oxygen gradient between the air we breathe (Po2 ~21 kPa) and its ultimate distribution within mitochondria (as low as ~0.5-1 kPa) is testament to the efforts expended in limiting its inherent toxicity. It has long been recognized that cell culture undertaken under room air conditions falls short of replicating this protection in vitro. Despite this, difficulty in accurately determining the appropriate O2 levels in which to culture cells, coupled with a lack of the technology to replicate and maintain a physiological O2 environment in vitro, has hindered addressing this issue thus far. In this review, we aim to address the current understanding of tissue Po2 distribution in vivo and summarize the attempts made to replicate these conditions in vitro. The state-of-the-art techniques employed to accurately determine O2 levels, as well as the issues associated with reproducing physiological O2 levels in vitro, are also critically reviewed. We aim to provide the framework for researchers to undertake cell culture under O2 levels relevant to specific tissues and organs. We envisage that this review will facilitate a paradigm shift, enabling translation of findings under physiological conditions in vitro to disease pathology and the design of novel therapeutics.
                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                (View ORCID Profile)
                Journal
                JCMOHK
                Journal of Clinical Medicine
                JCM
                MDPI AG
                2077-0383
                August 2022
                August 20 2022
                : 11
                : 16
                : 4885
                Article
                10.3390/jcm11164885
                36013124
                f42a681a-9eb6-4b42-8dbd-038361a42c64
                © 2022

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article