15
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Ten-Year Clinical Outcomes From a Trial of Three Limus-Eluting Stents With Different Polymer Coatings in Patients With Coronary Artery Disease : Results From the ISAR-TEST 4 Randomized Trial

      1 , 1 , 2 , 1 , 3 , 3 , 1 , 1 , 3 , 2 , 1 , 2 , 1 , 2 , 1 , 2 , On behalf of the ISAR-TEST 4 (Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents) Investigators
      Circulation
      Ovid Technologies (Wolters Kluwer Health)

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          New-generation drug-eluting stents offer the potential for enhanced late outcomes in comparison with early generation drug-eluting stents. However, assessment of extended long-term outcomes for these devices is lacking, especially regarding the comparison between new-generation drug-eluting stents with biodegradable or permanent polymers. The aim of this study is to compare the efficacy and safety of biodegradable polymer-based sirolimus-eluting stents (BP-SES; Yukon Choice PC) versus permanent polymer-based everolimus-eluting stents (PP-EES; Xience) versus early generation permanent polymer-based sirolimus-eluting stents (PP-SES; Cypher) at 10-year follow-up.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          Neoatherosclerosis: overview of histopathologic findings and implications for intravascular imaging assessment.

          Despite the reduction in late thrombotic events with newer-generation drug-eluting stents (DES), late stent failure remains a concern following stent placement. In-stent neoatherosclerosis has emerged as an important contributing factor to late vascular complications including very late stent thrombosis and late in-stent restenosis. Histologically, neoatherosclerosis is characterized by accumulation of lipid-laden foamy macrophages within the neointima with or without necrotic core formation and/or calcification. The development of neoatherosclerosis may occur in months to years following stent placement, whereas atherosclerosis in native coronary arteries develops over decades. Pathologic and clinical imaging studies have demonstrated that neoatherosclerosis occurs more frequently and at an earlier time point in DES when compared with bare metal stents, and increases with time in both types of implant. Early development of neoatherosclerosis has been identified not only in first-generation DES but also in second-generation DES. The mechanisms underlying the rapid development of neoatherosclerosis remain unknown; however, either absence or abnormal endothelial functional integrity following stent implantation may contribute to this process. In-stent plaque rupture likely accounts for most thrombotic events associated with neoatherosclerosis, while it may also be a substrate of in-stent restenosis as thrombosis may occur either symptomatically or asymptomatically. Intravascular optical coherence tomography is capable of detecting neoatherosclerosis; however, the shortcomings of this modality must be recognized. Future studies should assess the impact of iterations in stent technology and risk factor modification on disease progression. Similarly, refinements in imaging techniques are also warranted that will permit more reliable detection of neoatherosclerosis.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials.

            The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). We pooled individual patient data from three large-scale multicentre randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4, and LEADERS) comparing biodegradable polymer DES with durable polymer SES and assessed clinical outcomes during follow-up through 4 years. The efficacy endpoint of interest was target lesion revascularization and the safety endpoint of interest was definite stent thrombosis. Out of 4062 patients included in the present analysis, 2358 were randomly assigned to treatment with biodegradable polymer DES (sirolimus-eluting, n= 1501; biolimus-eluting, n= 857) and 1704 patients to durable polymer SES. No heterogeneity across the trials was observed in analyses of the primary and secondary endpoints. At 4 years, the risk of target lesion revascularization was significantly lower among patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.82, 95% CI 0.68-0.98, P= 0.029). In addition, the risk of stent thrombosis was significantly reduced with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.56, 95% CI 0.35-0.90, P= 0.015), driven by a lower risk of very late stent thrombosis (hazard ratio 0.22, 95% CI 0.08-0.61, P= 0.004). In keeping with this, in landmark analysis between 1 and 4 years, the incidence of myocardial infarction was lower for patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.59, 95% CI 0.73-0.95, P= 0.031). Biodegradable polymer DES improve safety and efficacy compared with durable polymer SES during long-term follow-up to 4 years.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Optical Coherence Tomography Findings in Patients With Coronary Stent Thrombosis

              Supplemental Digital Content is available in the text.
                Bookmark

                Author and article information

                Journal
                Circulation
                Circulation
                Ovid Technologies (Wolters Kluwer Health)
                0009-7322
                1524-4539
                January 15 2019
                January 15 2019
                : 139
                : 3
                : 325-333
                Affiliations
                [1 ]Deutsches Herzzentrum München, Technische Universität München, Munich (S.K., M.J., A.T., K.M., S.C., H.S., A.K., R.A.B.).
                [2 ]German Centre for Cardiovascular Research, Partner Site Munich Heart Alliance (M.J., K.-L.L., H.S., A.K., R.A.B.).
                [3 ]1. medizinische Klinik, Klinikum rechts der Isar, Technische Universität München, Munich (P.H., T.I., K.-L.L.).
                Article
                10.1161/CIRCULATIONAHA.118.038065
                30586724
                f2be152d-ff50-4702-94d7-3c680af1861f
                © 2019
                History

                Comments

                Comment on this article