10
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Long-term follow-up after surgical closure of ventricular septal defect in infancy and childhood

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The purpose of this study was to assess the health-related quality of life of patients who underwent surgical closure of a ventricular septal defect at a young age between 1968 and 1980. Since the beginning of open heart surgery for congenital cardiac malformations, the surgical techniques have continually improved. As a result, even infants have become eligible for surgical repair. Long-term follow-up data are not available on the health-related quality of life of nonselected patients after surgical repair at a young age. We therefore conducted a follow-up study of 176 infants and children consecutively operated on in one institution between 1968 and 1980. Patients who were alive and could be traced through the offices of local registrars received an invitation to participate in the follow-up study, consisting of an interview, physical examination, echocardiography, exercise testing and standard 12-lead and 24-h electrocardiography. One hundred nine patients (78% of those eligible for follow-up) participated. The mean interval after operation (+/- SD) was 14.5 +/- 2.6 years. Eighty-four percent of the patients assessed their health as good or very good, and 89% had been free of any medical or surgical intervention since the operation. At physical examination all patients were in good health. Their mean exercise capacity was 100 +/- 17% (range 56% to 141%) of predicted values; 84% of the patients had a normal exercise capacity. Echocardiography demonstrated a small residual ventricular septal defect in seven patients (6%). There were no signs of pulmonary hypertension. No patient had symptomatic arrhythmias. Long-term results of surgical closure of ventricular septal defect in infancy and childhood are good. Pulmonary hypertension is absent. Personal health assessment is comparable to that of the normal population, as is exercise capacity, even though many patients have anatomic, hemodynamic or electrophysiologic sequelae.

          Related collections

          Author and article information

          Journal
          Journal of the American College of Cardiology
          Journal of the American College of Cardiology
          Elsevier BV
          07351097
          November 1994
          November 1994
          : 24
          : 5
          : 1358-1364
          Article
          10.1016/0735-1097(94)90120-1
          7930261
          ef3eaa81-59fc-446a-88d8-1945430b9ff4
          © 1994

          https://www.elsevier.com/tdm/userlicense/1.0/

          https://www.elsevier.com/open-access/userlicense/1.0/

          History

          Comments

          Comment on this article