      A Possible Way for the Detection and Identification of Dangerous Substances in Ternary Mixtures Using THz Pulsed Spectroscopy

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We discuss an effective tool for the detection and identification of substances in ternary mixtures with similar spectral properties using a broadband reflected THz signal. Nowadays, this is an urgent problem; its effective solution is still far off. Two ternary mixtures of the explosives (RDX+TNT+HMX and RDX+TNT+PETN) were used as the examples for demonstration of the efficiency of the method proposed. The identification is based on the pulsed THz spectroscopy. We follow the spectral intensities together with the use of integral correlation criteria. They use the spectral line dynamics of the THz pulse reflected from the substance under investigation and that of the standard THz signal from database. In order to increase the accuracy and reliability of the identification, we analyze the partial non-overlapping time intervals, containing the main pulse of the reflected THz signal and the sequential sub-pulses. The main pulse is shown to contain information about high absorption frequencies (ν > 2.6 THz) of the mixture components. In the sub-pulses, the absorption frequencies of the components are detected in the range of low (ν < 2.6 THz) and high (ν > 2.6 THz) frequencies. The opportunity of distinguishing the mixtures with similar spectral properties is also shown.

          Related collections

          Most cited references58

          • Record: found
          • Abstract: not found
          • Article: not found

          THz imaging and sensing for security applications—explosives, weapons and drugs

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Terahertz optical rectification from 〈110〉 zinc‐blende crystals

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Detection and identification of explosive RDX by THz diffuse reflection spectroscopy.

              The reflection spectrum of the explosive RDX was acquired from a diffuse reflection measurement using a THz time-domain spectroscopy system in combination with a diffuse reflectance accessory. By applying the Kramers-Kronig transform to the reflection spectrum, the absorption spectrum (0.2-1.8 THz) was obtained. It agrees with the result from a transmission measurement and distinguishes RDX from other materials. The effect of the reference spectrum was examined by using both a Teflon pellet and a copper plate as references. The strong absorption of RDX at 0.82 THz allowed it to be identified by the diffuse reflection measurement even when the RDX sample was covered with certain optically opaque materials. Our investigation demonstrates that THz technique is capable of detecting and identifying hidden RDX-related explosives in a diffuse reflection mode, which is crucial for the standoff detection in the real world applications.
                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                22 May 2019
                May 2019
                : 19
                : 10
                : 2365
                Affiliations
                [1 ]School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, China
                [2 ]Faculty of Computational Mathematics and Cybernetics, Lomonosov Moscow State University, Leninskiye Gory, Moscow 119991, Russia; svarentsova@ 123456gmail.com
                Author notes
                [* ]Correspondence: vatro@ 123456cs.msu.ru ; Tel.: +7-495-939-5255
                Article
                sensors-19-02365
                10.3390/s19102365
                6567148
                31121987
                ee673201-7a5b-4a8d-8e34-481d96d33c3c
                © 2019 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 27 March 2019
                : 20 May 2019
                Categories
                Article

                Biomedical engineering
                pulsed thz time-domain spectroscopy,method of spectral dynamics analysis (sda-method),integral correlation criteria,detection and identification of substance,ternary mixture,dangerous substances,reflected pulse,spectra of sub-pulses

                Comments

                Comment on this article