      An Investigation of the Fracture Loads Involved in the Framework of Removable Partial Dentures Using Two Types of All-Ceramic Restorations

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Retention and support are needed for removable partial denture stability. The stability can be achieved by clasps, occlusal and cingulum rests on healthy abutment teeth. However, implants or crowns can be used to support the removable partial denture instated on unhealthy abutment teeth. This study was conducted to investigate the fracture strength of two types of all-ceramic restorations used as abutments for the removable partial denture framework. The crowns were manufactured with two types of ceramic materials: zirconia and IPS e.max Press ceramics. The metal alloy (cobalt-chrome) was cast to form the removable partial denture framework. A universal testing machine was used to evaluate the fracture strength of both ceramic crown materials. The results presented no fractures in all-ceramic crowns, but deformation of the partial denture frameworks occurred. With the limitation of this study, it can be concluded that zirconia and IPS e.max Press ceramic can be used as abutments to provide adequate support to the removable partial denture.

          Related collections

          Most cited references50

          • Record: found
          • Abstract: found
          • Article: not found

          Maximum voluntary molar bite force in subjects with normal occlusion.

          The aims of this investigation were to determine whether stabilization of maximum voluntary bite force (MVBF) occurs between 15 and 18 years of age in subjects with a normal occlusion, and to assess the influence of gender, body mass index (BMI), morphological occlusion, and jaw function measured by the number of occlusal contacts, overjet, overbite, maximal mouth opening, mandibular deflection during opening, sagittal slide between the retruded contact position and the intercuspal position, and number of dental restorations. The sample comprised 60 Caucasian subjects aged 15 (15 males and 15 females) and 18 (14 males and 16 females) years with a neutral occlusion, balanced facial profile, and absence of a previous orthodontic history. Bite force measurements were undertaken using a portable occlusal force gauge on both the left and the right sides of the jaw in the first molar region during maximal clenching. Two independent samples t-tests and multiple regression were used for statistical analysis. MVBFs were age and gender related (P<0.05). Males showed a significant increase in bite force between 15 and 18 years of age (P=0.002), but gender differences were significant only in the 18-year-olds (P=0.003). In subjects with a neutral occlusion, MVBF could best be predicted using multiple regression from age and gender. The regression model accounted for 31.3 percent of the variance in MVBF (P=0.031), with gender contributing 17.9 percent and age 7.9 percent. Morphological occlusion, jaw function, and BMI explained the remaining 5.5 percent of variance. While controlling for all other parameters, the independent contribution of gender to the prediction of MVBF was 16.2 percent, age 6 percent, number of occlusal contacts 3.2 percent, and BMI 1.3 percent.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Quantitative study of bite force during sleep associated bruxism.

            Nocturnal bite force during sleep associated bruxism was measured in 10 subjects. Hard acrylic dental appliances were fabricated for the upper and lower dentitions of each subject. Miniature strain-gauge transducers were mounted to the upper dental appliance at the right and left first molar regions. In addition, thin metal plates that contact the strain-gauge transducers were attached to the lower dental appliance. After a 1-week familiarization with the appliances, nocturnal bite force was measured for three nights at the home of each subject. From the 30 recordings, 499 bruxism events that met the definition criteria were selected. The above described system was also used to measure the maximum voluntary bite forces during the daytime. The mean amplitude of detected bruxism events was 22.5 kgf (s.d. 13.0 kgf) and the mean duration was 7.1 s (s.d. 5.3 s). The highest amplitude of nocturnal bite force in individual subjects was 42.3 kgf (15.6-81.2 kgf). Maximum voluntary bite force during the daytime was 79.0 kgf (51.8-99.7 kgf) and the mean ratio of nocturnal/daytime maximum bite force was 53.1% (17.3-111.6%). These data indicate that nocturnal bite force during bruxism can exceed the amplitude of maximum voluntary bite force during the daytime.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.

              Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported.
                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                Journal
                BIOMJE
                Biomimetics
                Biomimetics
                MDPI AG
                2313-7673
                March 2023
                March 09 2023
                : 8
                : 1
                : 113
                Article
                10.3390/biomimetics8010113
                ebc6b36f-475b-4a2a-8f9b-3b2b42c6f0e6
                © 2023

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content444

                Most referenced authors459