      Use of thermal imaging in dairy calves: exploring the repeatability and accuracy of measures taken from different anatomical regions 1

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Three experiments were undertaken to 1) quantify the repeatability and reproducibility of thermal imaging across day and operator experience and 2) assess the correlation between descriptive infrared (IR) temperature parameters from different anatomical areas and core body temperature in dairy calves under 12 wk of age. In experiment 1, a single operator captured 30 replicate images of both the left and right eyes (defined as the whole eye + 1 cm margin) and the rectal area (defined as the anus +1.5 cm margin) from each of 16 calves. In experiment 2, three operators of varying experience captured images from both the left and right eyes and the rectal area of each of 12 calves. In experiment 3, a single operator captured images of the right eye and rectal area for a period of 5 consecutive days for each of 205 calves. All images were captured between 0900 and 1300 h. Core body temperature, obtained via rectal thermometer, was recorded every day for each of the 205 calves following completion of IR image capture. Ambient temperature and relative humidity were adjusted for each thermal image prior to manual extraction of maximum, minimum, and average temperature parameters. In experiment 1, lowest error variance was found within the maximum temperature parameter and the right eye was determined as the most repeatable anatomical area, with 80.48% of the total proportion of variance attributed to the calf. Results indicated that capturing at least three replicate images would provide the precision required to identify ill-health in calves. In experiment 2, operator variance was low across anatomical areas, with values of ≤0.01°C 2 for the right and left eyes and ≤0.04°C 2 for the rectal area. In experiment 3, day to day variation of thermal image measurements and core body temperature were minimal across anatomical areas with values of ≤0.008°C 2. Correlations ranging from 0.16 to 0.32, and from 0.31 to 0.47 were found between maximum eye and core body temperature and maximum rectal area and core body temperature, respectively. Results of the present study indicate a low level of variability and high level of repeatability within IR temperature measurements in calves under 12 wk of age, particularly within maximum temperature parameters. Providing operators of varying abilities with a basic standardized protocol is sufficient to limit between-operator variation. Further research is required to investigate whether correlation between IR and core body temperature can be improved.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          A reappraisal of the use of infrared thermal image analysis in medicine.

          B.F. Jones (1998)
          Infrared thermal imaging of the skin has been used for several decades to monitor the temperature distribution of human skin. Abnormalities such as malignancies, inflammation, and infection cause localized increases in temperature which show as hot spots or as asymmetrical patterns in an infrared thermogram. Even though it is nonspecific, infrared thermology is a powerful detector of problems that affect a patient's physiology. While the use of infrared imaging is increasing in many industrial and security applications, it has declined in medicine probably because of the continued reliance on first generation cameras. The transfer of military technology for medical use has prompted this reappraisal of infrared thermology in medicine. Digital infrared cameras have much improved spatial and thermal resolutions, and libraries of image processing routines are available to analyze images captured both statically and dynamically. If thermographs are captured under controlled conditions, they may be interpreted readily to diagnose certain conditions and to monitor the reaction of a patient's physiology to thermal and other stresses. Some of the major areas where infrared thermography is being used successfully are neurology, vascular disorders, rheumatic diseases, tissue viability, oncology (especially breast cancer), dermatological disorders, neonatal, ophthalmology, and surgery.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Non-invasive measurement of stress in dairy cows using infrared thermography.

            The possibility that changes in eye temperature, measured using infrared thermography (IRT), can detect stress in dairy cattle was examined by six different stimulations of the stress axis. Six cows were given six treatments in a random Latin-square design: 1) Control (saline) 2) ACTH (0.05 mg Synacthen) 3) bCRH (20 mug) 4) bCRH (40 mug) 5) epinephrine (1.4 mug /kg liveweight) and 6) social isolation. Treatments were administered at time 0 and blood samples were taken at -30, -15, 0, 5, 10, 15, 20, 30, 40, 50, 60, 75, 90, 120, 180 and 240 min except for epinephrine which was sampled at -30, -15, -10, -5, 0, 2, 5, 10, 15, 20, 30, 45, 60, 90 and 120 min. Core body temperature was recorded every 10 min and eye images collected every 2 min. Eye temperature and cortisol increased following catheterization (P<0.05). ACTH increased following bCRH, cortisol increased following ACTH and bCRH (P<0.001) and NEFA increased following epinephrine (P<0.001). Core body temperature was unaffected by treatments. Eye temperature was unaffected by CRH and epinephrine but was higher 30 and 60 min following control and ACTH (P<0.001). Our results provide evidence that exogenous HPA stimulation does not increase eye temperature. The increases in eye temperature following catheterization however raise the possibility that a cognitive component may be required for an eye temperature response to occur.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Monitoring the body temperature of cows and calves using video recordings from an infrared thermography camera.

              The aim of this study was to assess the variability of temperatures measured by a video-based infrared camera (IRC) in comparison to rectal and vaginal temperatures. The body surface temperatures of cows and calves were measured contactless at different body regions using videos from the IRC. Altogether, 22 cows and 9 calves were examined. The differences of the measured IRC temperatures among the body regions, i.e. eye (mean: 37.0 °C), back of the ear (35.6 °C), shoulder (34.9 °C) and vulva (37.2 °C), were significant (P < 0.01), except between eye and vulva (P = 0.99). The quartile ranges of the measured IRC temperatures at the 4 above mentioned regions were between 1.2 and 1.8 K. Of the investigated body regions the eye and the back of the ear proved to be suitable as practical regions for temperature monitoring. The temperatures of these 2 regions could be gained by the use of the maximum temperatures of the head and body area. Therefore, only the maximum temperatures of both areas were used for further analysis. The data analysis showed an increase for the maximum temperature measured by IRC at head and body area with an increase of rectal temperature in cows and calves. The use of infrared thermography videos has the advantage to analyze more than 1 picture per animal in a short period of time, and shows potential as a monitoring system for body temperatures in cattle.
                Bookmark

                Author and article information

                Journal
                Transl Anim Sci
                Transl Anim Sci
                tas
                Translational Animal Science
                Oxford University Press (US )
                2573-2102
                January 2019
                18 November 2018
                18 November 2018
                : 3
                : 1
                : 564-576
                Affiliations
                [1 ]Agri-Food and Biosciences Institute, Hillsborough, Northern Ireland, Northern Ireland
                [2 ]Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, Northern Ireland
                [3 ]Agri-Food and Biosciences Institute, Newforge Lane, Belfast, Northern Ireland
                Author notes
                Article
                txy126
                10.1093/tas/txy126
                7200435
                32704827
                e5b82d39-9367-46f0-b507-7e8e3db81984
                © The Author(s) 2018. Published by Oxford University Press on behalf of the American Society of Animal Science.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com

                History
                : 10 September 2018
                : 15 November 2018
                Page count
                Pages: 13
                Categories
                Technology in Animal Science

                accuracy,dairy calves,infrared thermography,repeatability,temperature assessment

                Comments

                Comment on this article