33
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Performance Evaluation of an Infrared Thermocouple

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The measurement of the leaf temperature of forests or agricultural plants is an important technique for the monitoring of the physiological state of crops. The infrared thermometer is a convenient device due to its fast response and nondestructive measurement technique. Nowadays, a novel infrared thermocouple, developed with the same measurement principle of the infrared thermometer but using a different detector, has been commercialized for non-contact temperature measurement. The performances of two-kinds of infrared thermocouples were evaluated in this study. The standard temperature was maintained by a temperature calibrator and a special black cavity device. The results indicated that both types of infrared thermocouples had good precision. The error distribution ranged from −1.8 °C to 18 °C as the reading values served as the true values. Within the range from 13 °C to 37 °C, the adequate calibration equations were the high-order polynomial equations. Within the narrower range from 20 °C to 35 °C, the adequate equation was a linear equation for one sensor and a two-order polynomial equation for the other sensor. The accuracy of the two kinds of infrared thermocouple was improved by nearly 0.4 °C with the calibration equations. These devices could serve as mobile monitoring tools for in situ and real time routine estimation of leaf temperatures.

          Related collections

          Most cited references30

          • Record: found
          • Abstract: not found
          • Article: not found

          Use of infrared thermometry for estimation of stomatal conductance as a possible aid to irrigation scheduling

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Classical and modern regression with applications.

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Development of crop water stress index of wheat crop for scheduling irrigation using infrared thermometry

                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel, Switzerland)
                Molecular Diversity Preservation International (MDPI)
                1424-8220
                2010
                10 November 2010
                : 10
                : 11
                : 10081-10094
                Affiliations
                [1 ] Department of Bio-industrial Mechatronics Engineering, National ChungHsing University, 250 Kuokuang Road, Taichung, Taiwan
                [2 ] Department of Biomechatronics Engineering, National Chia-I University, Chia-I, Taiwan
                Author notes
                [* ]Author to whom correspondence should be addressed; E-Mail: ccchen@ 123456dragon.nchu.edu.tw ; Tel.: +886-4-2285-7562; Fax: +886-4-2285-7135.
                Article
                sensors-10-10081
                10.3390/s101110081
                3231037
                22163458
                e41a3a78-1399-4006-852b-2abfa0e0e00c
                © 2010 by the authors; licensee MDPI, Basel, Switzerland.

                This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license ( http://creativecommons.org/licenses/by/3.0/.)

                History
                : 28 October 2010
                : 2 November 2010
                : 8 November 2010
                Categories
                Article

                Biomedical engineering
                infrared thermocouple,leaf temperature,thermometer,calibration equation
                Biomedical engineering
                infrared thermocouple, leaf temperature, thermometer, calibration equation

                Comments

                Comment on this article