      Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          To compare corneal hysteresis (CH) measurements between patients with glaucoma, ocular hypertension (OHT) and glaucoma-like optic discs (GLD)- defined as a cup to disc ratio greater than or equal to 0.6 with normal intraocular pressure (IOP) and visual fields. The secondary aim was to investigate whether corneal resistance factor (CRF) and central corneal thickness (CCT) differ between patient groups.

          Methods

          In this cross sectional study a total of 123 patients (one eye each) were recruited from a glaucoma outpatient department to undergo ocular response analyser (ORA) testing and ultrasound pachymetry as well as clinical examination. A One-way Analysis of Covariance (ANCOVA) was conducted to evaluate the mean difference in CH between the three diagnostic groups (glaucoma, OHT and GLD) correcting for potential confounding factors, IOP and age. Analysis was repeated for CRF and CCT.

          Results

          There was a significant difference in mean CH across the three diagnosis groups; F(2, 115) = 96.95; p < 0.001. Mean CH significantly higher for GLD compared to glaucoma (mean difference 1.83, p < 0.001), and significantly higher for OHT compared to glaucoma (mean difference 2.35, p < 0.001). Mean CH was slightly lower in patients with GLD than those with OHT but this difference was not statistically significant. A similar pattern was seen when the analysis was repeated for CRF and CCT.

          Conclusions

          Higher CH in GLD and OHT compared to glaucoma suggests increased viscoelasticity of ocular tissues may have a protective role against glaucoma.

          Related collections

          Most cited references22

          • Record: found
          • Abstract: found
          • Article: not found

          Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

          David Luce (2005)
          To study the results of an ocular response analyzer (ORA) to determine the biomechanical properties of the cornea and their relationship to intraocular pressure (IOP). Reichert Inc., Depew, New York, USA. The ORA (Reichert) makes 2 essentially instantaneous applanation measurements that permit determination of corneal and IOP effects. Measurements of several populations indicate that corneal hysteresis, a biomechanical measure, varied over a dynamic range of 1.8 to 14.6 mm Hg and was only weakly correlated with corneal thickness (r(2)=0.12); this is related to the observation that some subjects with relatively thick corneas have less-than-average corneal hysteresis. Corneal hysteresis changes diurnally, presumably as a result of hydration changes. Keratoconus, Fuchs' dystrophy, and post-LASIK patients demonstrated low corneal hysteresis. The corneal hysteresis biomechanical measure may prove valuable for qualification and predictions of outcomes of refractive surgery and in other cases in which corneal biomechanics are important.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Prevalence of glaucoma. The Beaver Dam Eye Study.

            The purpose of this study is to determine the prevalence of glaucoma in the population participating in the Beaver Dam Eye Study (n = 4926). All subjects were examined according to standard protocols, which included applanation tonometry, examination of the anterior chamber, perimetry, grading of fundus photographs of the optic disc, and a medical history interview. Visual field, cup-to-disc ratio, and intraocular pressure (IOP) criteria were used to define the presence of open-angle glaucoma. Definite open-angle glaucoma was defined by the presence of any two or all three of the following: abnormal visual field, large or asymmetric cup-to-disc ratio, high IOP. The overall prevalence of definite open-angle glaucoma was 2.1%. The prevalence increased with age from 0.9% in people 43 to 54 years of age to 4.7% in people 75 years of age or older. There was no significant effect of sex after adjusting for age. Of the 104 cases of definite open-angle glaucoma, 33 had IOPs less than 22 mmHg in the involved eye. Hemorrhage on the optic disc was found in 46 people; 2 of these had glaucoma. Narrow-angle glaucoma was rare, with two definite cases in the population. The prevalence of open-angle glaucoma in Beaver Dam is similar to that in other white populations. Findings from this study re-emphasize the notion that estimates of glaucoma prevalence should be based on assessing multiple risk indicators.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Biomechanics of the human posterior sclera: age- and glaucoma-related changes measured using inflation testing.

              The objective of this study was to measure the biomechanical response of the human posterior sclera in vitro and to estimate the effects of age and glaucoma. Scleral specimens from 22 donors with no history of glaucoma and 11 donors with a history of glaucoma were excised 3 mm posterior to the equator and affixed to an inflation chamber. Optic nerve cross-sections were graded to determine the presence of axon loss. The time-dependent inflation response was measured in a series of pressure-controlled load-unload tests to 30 mm Hg and creep tests to 15 and 30 mm Hg. Circumferential and meridional strains were computed from the digital image correlation displacements, and midposterior stresses were determined from pressure and deformed geometry. Among normal specimens, older age was predictive of a stiffer response and a thinner sclera. In the age group 75 to 93, diagnosed glaucoma eyes with axon damage were thicker than normal eyes. Both damaged and undamaged glaucoma eyes had a different strain response in the peripapillary sclera characterized by a stiffer meridional response. Undamaged glaucoma eyes had slower circumferential creep rates in the peripapillary sclera than normal eyes. Glaucoma eyes were not different from normal eyes in stresses and strains in the midposterior sclera. The observed differences in the biomechanical response of normal and glaucoma sclera may represent baseline properties that contribute to axon damage, or may be characteristics that result from glaucomatous disease.
                Bookmark

                Author and article information

                Contributors
                00353863733956 , murphm24@tcd.ie
                olya.pokrovskaya@gmail.com
                marie.galligan@ucd.ie
                cobrien@mater.ie
                Journal
                BMC Ophthalmol
                BMC Ophthalmol
                BMC Ophthalmology
                BioMed Central (London )
                1471-2415
                10 January 2017
                10 January 2017
                2017
                : 17
                : 1
                Affiliations
                School of Medicine and Medical Sciences, Mater Misericordiae University Hospital, Eccles Street Dublin 7, Dublin, Ireland
                Article
                396
                10.1186/s12886-016-0396-9
                5223406
                28068950
                e3f02eb9-19b0-4b95-9d24-d65fb706619f
                © The Author(s). 2017

                Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 12 August 2016
                : 16 December 2016
                Categories
                Research Article
                Custom metadata
                © The Author(s) 2017

                Ophthalmology & Optometry
                corneal hysteresis,corneal resistance factor,glaucoma-like optic discs,central corneal thickness,ocular response analyser

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content544

                Cited by40

                Most referenced authors253