      Holmium: YAG Lithotripsy: Photothermal Mechanism

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: not found
          • Article: not found

          Laser-Tissue Interactions: Photochemical, Photothermal, and Photomechanical

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Temperature dependence of the absorption coefficient of water for midinfrared laser radiation

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Effect of pulse duration on bubble formation and laser-induced pressure waves during holmium laser ablation.

              One concern during laser ablation of tissue is the mechanical injury that may be induced in tissue in the vicinity of the ablation site. This injury is primarily due to rapid bubble expansion and collapse or due to laser-induced pressure waves. In this study, the effect of laser pulse duration on the thermodynamics of bubble formation and accompanying acoustic pressure wave generation has been investigated. Q-switched holmium:YAG laser pulses (pulse duration 500 ns, pulse energy 14 mJ) and free-running holmium:YAG laser pulses (pulse duration 100-1,100 microseconds, pulse energy 200 mJ) were delivered in water and tissue phantoms via a 200- and 400-microns fiber, respectively. The tissue phantoms consisted of polyacrylamide gels with varying mechanical strengths. Bubble formation was recorded with a fast flash photography setup, while acoustic transients were measured with a needle hydrophone. It was observed that, as the pulse length was increased the bubble shape changed from almost spherical for Q-switched pulses to a more elongated cylinder shape for longer pulse durations. The bubble expansion velocity was larger for shorter pulse durations. Only the Q-switched pulse induced a measurable thermo-elastic expansion wave. All pulses that induced bubble formation generated pressure waves upon collapse of the bubble in gels as well as in water. However, the magnitude of the pressure wave depended strongly on the size and geometry of the induced bubble. The magnitude of the collapse pressure wave decreased as laser pulse duration increased. Hence it may be possible to reduce collateral mechanical tissue damage by stretching the holmium laser pulse.
                Bookmark

                Author and article information

                Journal
                Journal of Endourology
                Journal of Endourology
                Mary Ann Liebert Inc
                0892-7790
                1557-900X
                April 1999
                April 1999
                : 13
                : 3
                : 181-190
                Article
                10.1089/end.1999.13.181
                e0a4a39a-0f36-48f4-85b2-9241e832e562
                © 1999
                History

                Comments

                Comment on this article