      RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references13

          • Record: found
          • Abstract: found
          • Article: not found

          Comparison of Heart Rate Variability Recording With Smart Phone Photoplethysmographic, Polar H7 Chest Strap and Electrocardiogram Methods

          To establish the validity of smartphone photoplethysmography (PPG) and heart-rate sensor in the measurement of heart-rate variability (HRV).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Comparison of three mobile devices for measuring R-R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system.

            The first aim of this study was to compare an ambulatory five-lead ECG system with the commercially available breast belt measuring devices; Polar S810i and Suunto t6, in terms of R-R interval measures and heart rate variability (HRV) indices. The second aim was to compare different HRV spectral analysis methods. Nineteen young males (aged between 22 and 31 years, median 24 years) underwent simultaneous R-R interval recordings with the three instruments during supine and sitting rest, moderate dynamic, and moderate to vigorous static exercise of the upper and lower limb. For each subject, 17 R-R interval series of 3-min length were extracted from the whole recordings and then analyzed in frequency domain using (1) a fast Fourier transform (FFT), (2) an autoregressive model (AR), (3) a Welch periodogram (WP) and (4) a continuous wavelet transform (CWT). Intra-class correlation coefficients (ICC) and Bland-Altman limits of agreement (LoA) method served as criteria for measurement agreement. Regarding the R-R interval recordings, ICC (lower ICC 95% confidence interval >0.99) as well as LoA (maximum LoA: -15.1 to 14.3 ms for ECG vs. Polar) showed an excellent agreement between all devices. Therefore, the three instruments may be used interchangeably in recording and interpolation of R-R intervals. ICCs for HRV frequency parameters were also high, but in most cases LoA analysis revealed unacceptable discrepancies between the instruments. The agreement among the different frequency transform methods can be taken for granted when analyzing the normalized power in low and high frequency ranges; however, not when analyzing the absolute values.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Power spectrum analysis of heart rate variability: a tool to explore neural regulatory mechanisms.

                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                Journal
                European Journal of Applied Physiology
                Eur J Appl Physiol
                Springer Science and Business Media LLC
                1439-6319
                1439-6327
                July 2019
                April 19 2019
                July 2019
                : 119
                : 7
                : 1525-1532
                Article
                10.1007/s00421-019-04142-5
                31004219
                d8a18ba6-a729-443c-a622-1459dac720ea
                © 2019

                http://www.springer.com/tdm

                History

                Comments

                Comment on this article