      Simple ultrasensitive electrochemical detection of the DBP plasticizer for the risk assessment of South Korean river waters

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We present a simple electrochemical strategy for the ultrasensitive quantitative analysis of DBP plasticizer in water. The proposed aptasensor is comparable to GC-MS in sensitivity and it was applied to monitor the river waters contamination.

          Abstract

          Rapid detection of contaminants for the purpose of sensitive and quantitative monitoring of environmental hazards is an essential first step in realizing the avoidance of human health risks. In this regard, we present a fast and simple electrochemical method of detecting di- n-butyl phthalate (DBP) from river water samples using a phthalic acid group specific aptamer modified on a gold nanoparticle (AuNP) functionalized graphene oxide nano-platelet (GO) and ionic liquid (IL) nanocomposite. Here, the IL/GO nanocomposite allows an enhanced interaction with phthalate esters, thereby increasing the sensitivity of the sensor surface. The proposed sensor showed a wide linear dynamic range from 0.14 pg mL −1 to 0.35 ng mL −1 and from 0.35 ng mL −1 to 7 ng mL −1 with a detection limit of ≤0.042 pg mL −1, which were evaluated using standard, analytical grade DBP; the limit of quantification was determined using different concentrations of DBP in DI water in comparison with gas chromatography-mass spectroscopy (GC/MS) values. The proposed sensor was used to monitor the DBP concentrations in river water samples collected from various locations across South Korea. The quantitative data from the measurements in comparison with standard GC/MS values were then used to ascertain the human health risk posed by the daily consumption of these river waters.

          Related collections

          Most cited references34

          • Record: found
          • Abstract: not found
          • Article: not found

          Functionalization of graphene: covalent and non-covalent approaches, derivatives and applications.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Rapid electrochemical detection of coronavirus SARS-CoV-2

            Coronavirus disease 2019 (COVID-19) is a highly contagious disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Diagnosis of COVID-19 depends on quantitative reverse transcription PCR (qRT-PCR), which is time-consuming and requires expensive instrumentation. Here, we report an ultrasensitive electrochemical biosensor based on isothermal rolling circle amplification (RCA) for rapid detection of SARS-CoV-2. The assay involves the hybridization of the RCA amplicons with probes that were functionalized with redox active labels that are detectable by an electrochemical biosensor. The one-step sandwich hybridization assay could detect as low as 1 copy/μL of N and S genes, in less than 2 h. Sensor evaluation with 106 clinical samples, including 41 SARS-CoV-2 positive and 9 samples positive for other respiratory viruses, gave a 100% concordance result with qRT-PCR, with complete correlation between the biosensor current signals and quantitation cycle (Cq) values. In summary, this biosensor could be used as an on-site, real-time diagnostic test for COVID-19.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Aptamers as a replacement for antibodies in enzyme-linked immunosorbent assay.

              The application of antibodies in enzyme-linked immunosorbent assay (ELISA) is the basis of this diagnostic technique which is designed to detect a potpourri of complex target molecules such as cell surface antigens, allergens, and food contaminants. However, development of the systematic evolution of Ligands by Exponential Enrichment (SELEX) method, which can generate a nucleic acid-based probe (aptamer) that possess numerous advantages compared to antibodies, offers the possibility of using aptamers as an alternative molecular recognition element in ELISA. Compared to antibodies, aptamers are smaller in size, can be easily modified, are cheaper to produce, and can be generated against a wide array of target molecules. The application of aptamers in ELISA gives rise to an ELISA-derived assay called enzyme-linked apta-sorbent assay (ELASA). As with the ELISA method, ELASA can be used in several different configurations, including direct, indirect, and sandwich assays. This review provides an overview of the strategies involved in aptamer-based ELASA.
                Bookmark

                Author and article information

                Contributors
                Journal
                ANALAO
                The Analyst
                Analyst
                Royal Society of Chemistry (RSC)
                0003-2654