      GFR estimation using standardized serum cystatin C in Japan.

      American Journal of Kidney Diseases
      Cystatin C, blood, Female, Glomerular Filtration Rate, Humans, Japan, Kidney Function Tests, standards, Male, Mathematics, Middle Aged

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Recently, the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) developed glomerular filtration rate (GFR)-estimating equations based on standardized serum cystatin C (CKD-EPI(cys)) and standardized serum creatinine plus standardized serum cystatin C (CKD-EPI(cr-cys)). We developed new GFR-estimating equations based on standardized cystatin C for a Japanese population and compared their accuracy with the CKD-EPI equations. Accuracy of diagnostic test study. 413 (development data set) and 350 individuals (validation data set). CKD-EPI(cys); CKD-EPI(cr-cys); modifications to CKD-EPI(cys) and CKD-EPI(cr-cys) using Japanese coefficients; and newly developed Japanese eGFR equations based on standardized serum cystatin C (Eq(cys)), cystatin C with a nonrenal factor reflecting hypothesized extrarenal elimination (Eq(cys+nonrenal)), and creatinine in combination with cystatin C (Eq(cr-cys)). Standardized cystatin C values were determined by a colloidal gold immunoassay traceable to the international certified reference material ERM-DA471/IFCC. Measured GFR by inulin renal clearance. In a development data set, we calculated Japanese coefficients for CKD-EPI(cys) and CKD-EPI(cr-cys) of 0.977 (95% CI, 0.853-1.002) and 0.908 (95% CI, 0.889-0.928), respectively. In a validation data set, we compared CKD-EPI(cys), Eq(cys), and Eq(cys+nonrenal) with each other. Bias and accuracy were not significantly different among the 3 equations. The precision of CKD-EPI(cys) was significantly better than for Eq(cys) (P = 0.007) and not significantly different from Eq(cys+nonrenal) (P = 0.6). We then compared 0.908 × CKD-EPI(cr-cys), Eq(cr-cys), and Eq(average) (the average value of Eq(cr) [previous Japanese equation based on standardized serum creatinine] and Eq(cys+nonrenal)) with each other in the validation data set. Bias and accuracy were not significantly different among the 3 equations. The precision of 0.908 × CKD-EPI(cr-cys) was significantly better than for Eq(cr-cys) (P = 0.004) and not significantly different from Eq(average) (P = 0.06). Limited number of participants with measured GFR >90 mL/min/1.73 m(2). Extrarenal elimination of cystatin C was not measured. CKD-EPI(cys) performed well in Japanese individuals, suggesting that equations based on serum cystatin C could be used in patients with different races without modification. Accounting for extrarenal elimination of cystatin C may improve the performance of estimating equations. Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Journal
          22892396
          10.1053/j.ajkd.2012.07.007

          Chemistry
          Cystatin C,blood,Female,Glomerular Filtration Rate,Humans,Japan,Kidney Function Tests,standards,Male,Mathematics,Middle Aged

          Comments

          Comment on this article