0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Simultaneous tensile and shear measurement of the human cornea in vivo using S0- and A0-wave optical coherence elastography

      , ,
      Acta Biomaterialia
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references45

          • Record: found
          • Abstract: found
          • Article: not found

          Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

          David Luce (2005)
          To study the results of an ocular response analyzer (ORA) to determine the biomechanical properties of the cornea and their relationship to intraocular pressure (IOP). Reichert Inc., Depew, New York, USA. The ORA (Reichert) makes 2 essentially instantaneous applanation measurements that permit determination of corneal and IOP effects. Measurements of several populations indicate that corneal hysteresis, a biomechanical measure, varied over a dynamic range of 1.8 to 14.6 mm Hg and was only weakly correlated with corneal thickness (r(2)=0.12); this is related to the observation that some subjects with relatively thick corneas have less-than-average corneal hysteresis. Corneal hysteresis changes diurnally, presumably as a result of hydration changes. Keratoconus, Fuchs' dystrophy, and post-LASIK patients demonstrated low corneal hysteresis. The corneal hysteresis biomechanical measure may prove valuable for qualification and predictions of outcomes of refractive surgery and in other cases in which corneal biomechanics are important.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-A-induced cross-linking.

            To evaluate the biomechanical effect of combined riboflavin-ultraviolet A (UVA) treatment on porcine and human corneas. Department of Ophthalmology, Technical University of Dresden, Dresden, Germany. Corneal strips from 5 human enucleated eyes and 20 porcine cadaver corneas were treated with the photosensitizer riboflavin and irradiated with 2 double UVA diodes (370 nm, irradiance = 3 mW/cm2) for 30 minutes. After cross-linking, static stress-strain measurements of the treated and untreated corneas were performed using a microcomputer-controlled biomaterial tester with a prestress of 5 x 10(3) Pa. There was a significant increase in corneal rigidity after cross-linking, indicated by a rise in stress in treated porcine corneas (by 71.9%) and human corneas (by 328.9%) and in Young's modulus by the factor 1.8 in porcine corneas and 4.5 in human corneas. The mean central corneal thickness was 850 microm +/- 70 (SD) in porcine corneas and 550 +/- 40 microm in human corneas. Riboflavin-UVA-induced collagen cross-linking led to an increase in mechanical rigidity in porcine corneas and an even greater increase in human corneas. As collagen cross-linking is maximal in the anterior 300 microm of the cornea, the greater stiffening effect in human corneas can be explained by the relatively larger portion of the cornea being cross-linked in the overall thinner human cornea.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Hyperelastic modelling of arterial layers with distributed collagen fibre orientations.

              Constitutive relations are fundamental to the solution of problems in continuum mechanics, and are required in the study of, for example, mechanically dominated clinical interventions involving soft biological tissues. Structural continuum constitutive models of arterial layers integrate information about the tissue morphology and therefore allow investigation of the interrelation between structure and function in response to mechanical loading. Collagen fibres are key ingredients in the structure of arteries. In the media (the middle layer of the artery wall) they are arranged in two helically distributed families with a small pitch and very little dispersion in their orientation (i.e. they are aligned quite close to the circumferential direction). By contrast, in the adventitial and intimal layers, the orientation of the collagen fibres is dispersed, as shown by polarized light microscopy of stained arterial tissue. As a result, continuum models that do not account for the dispersion are not able to capture accurately the stress-strain response of these layers. The purpose of this paper, therefore, is to develop a structural continuum framework that is able to represent the dispersion of the collagen fibre orientation. This then allows the development of a new hyperelastic free-energy function that is particularly suited for representing the anisotropic elastic properties of adventitial and intimal layers of arterial walls, and is a generalization of the fibre-reinforced structural model introduced by Holzapfel & Gasser (Holzapfel & Gasser 2001 Comput. Meth. Appl. Mech. Eng. 190, 4379-4403) and Holzapfel et al. (Holzapfel et al. 2000 J. Elast. 61, 1-48). The model incorporates an additional scalar structure parameter that characterizes the dispersed collagen orientation. An efficient finite element implementation of the model is then presented and numerical examples show that the dispersion of the orientation of collagen fibres in the adventitia of human iliac arteries has a significant effect on their mechanical response.
                Bookmark

                Author and article information

                Contributors
                Journal
                Acta Biomaterialia
                Acta Biomaterialia
                Elsevier BV
                17427061
                February 2024
                February 2024
                : 175
                : 114-122
                Article
                10.1016/j.actbio.2023.12.019
                10872441
                38101555
                c5fe5682-62b2-417e-a183-888ae0eb486e
                © 2024

                https://www.elsevier.com/tdm/userlicense/1.0/

                http://www.elsevier.com/open-access/userlicense/1.0/

                History

                Comments

                Comment on this article