7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Bedside ultrasound in pediatric critical care: A review :

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references55

          • Record: found
          • Abstract: found
          • Article: not found

          American College of Chest Physicians/La Société de Réanimation de Langue Française statement on competence in critical care ultrasonography.

          To define competence in critical care ultrasonography (CCUS). The statement is sponsored by the Critical Care NetWork of the American College of Chest Physicians (ACCP) in partnership with La Société de Réanimation de Langue Française (SRLF). The ACCP and the SRLF selected a panel of experts to review the field of CCUS and to develop a consensus statement on competence in CCUS. CCUS may be divided into general CCUS (thoracic, abdominal, and vascular), and echocardiography (basic and advanced). For each component part, the panel defined the specific skills that the intensivist should have to be competent in that aspect of CCUS. In defining a reasonable minimum standard for CCUS, the statement serves as a guide for the intensivist to follow in achieving proficiency in the field.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Ultrasonic locating devices for central venous cannulation: meta-analysis.

            To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVENTION REVIEWED: Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation. Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation. 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38). Evidence supports the use of two dimensional ultrasonography for central venous cannulation.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The "lung point": an ultrasound sign specific to pneumothorax.

              We studied an ultrasound sign, the fleeting appearance of a lung pattern (lung sliding or pathologic comet-tail artifacts) replacing a pneumothorax pattern (absent lung sliding plus exclusive horizontal lines) in a particular location of the chest wall. This sign was called the "lung point". Prospective study. The medical ICU of a university-affiliated teaching hospital. The "lung point" was sought in 66 consecutive cases of proven pneumothorax analyzable using ultrasound--including 8 radio-occult cases diagnosed by means of CT and in 233 consecutive hemithoraces studied by CT and free of pneumothorax-- including 17 cases where pneumothorax was suspected. The "lung point" was observed in 44 of 66 cases of pneumothorax (including 6 of 8 radio-occult cases) and in no case in the control group. The location of this sign roughly correlated with the radiological size of the pneumothorax. The "lung point" therefore had an overall sensitivity of 66 % (75 % in the case of radio-occult pneumothorax alone) and a specificity of 100%. The presence of a "lung point" allows positive diagnosis of pneumothorax at the bedside using ultrasound.
                Bookmark

                Author and article information

                Journal
                Pediatric Critical Care Medicine
                Pediatric Critical Care Medicine
                Ovid Technologies (Wolters Kluwer Health)
                1529-7535
                2011
                November 2011
                : 12
                : 6
                : 667-674
                Article
                10.1097/PCC.0b013e318223147e
                21666528
                c303bb49-3189-43e3-aec2-907600bacd04
                © 2011
                History

                Comments

                Comment on this article