10
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Bilateral Ultrathin Descemet’s Stripping Automated Endothelial Keratoplasty vs. Bilateral Penetrating Keratoplasty in Fuchs’ Dystrophy: Corneal Higher-Order Aberrations, Contrast Sensitivity and Quality of Life

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet’s stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs’ endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quality of life (QoL). Results: The mean follow-up after the second eye surgery was 32.5 ± 10.2 months in PK and 19.6 ± 8.6 months in UT-DSAEK patients. The CDVA in the UT-DSAEK group was significantly better than in the PK one (0.18 ± 0.07 vs. 0.35 ± 0.16 logMAR, p < 0.0001). The mean anterior corneal total HOAs of the central 5 mm were significantly lower in UT-DSAEK eyes than in PK eyes (0.438 ± 0.078 µ and 1.282 ± 0.330 µ respectively, p < 0.0001), whilst the mean posterior total HOAs did not differ between groups (0.196 ± 0.056 µ and 0.231 ± 0.089 µ, respectively, p = 0.253). The CS was lower at 0.75 and 1.5 cycles/degree in P the K group when compared to the DSAEK one ( p = 0.008 and 0.005, respectively). The QoL scores by the NEI RQL-42 test exhibited better values in DSAEK patients in 9 out of 13 scales. Conclusion: Our study confirms that UT-DSAEK provides a better visual function in terms of CDVA and CS, together with lower HOAs, when compared to PK. Hence, the vision-related QoL, binocularly evaluated by the NEI RQL-42 items, indicates a higher satisfaction in UT-DSAEK eyes.

          Related collections

          Most cited references42

          • Record: found
          • Abstract: found
          • Article: not found

          Development of the 25-item National Eye Institute Visual Function Questionnaire.

          To develop and test the psychometric properties of a 25-item version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). Prospective observational cohort study of persons with 1 of 5 chronic eye diseases or low vision who were scheduled for nonurgent visits in ophthalmology practices and a reference sample of persons without eye disease. Eleven university-based ophthalmology practices and the NEI Clinical Center. Eligible participants had to have 1 of the following eye conditions: age-related cataracts, age-related macular degeneration, diabetic retinopathy, primary open-angle glaucoma, cytomegalovirus retinitis, or low vision from any cause. Seven of the 12 sites also enrolled persons in a reference sample. Reference sample participants had no evidence of underlying eye disease but were scheduled for either screening eye examinations or correction of refractive error. All eligible persons had to be 21 years or older, English speaking, and cognitively able to give informed consent and participate in a health status interview. To provide the data needed to create the NEI VFQ-25, all subjects completed an interview that included the 51-item NEI VFQ. Estimates of internal consistency indicate that the subscales of the NEI VFQ-25 are reliable. The validity of the NEI VFQ-25 is supported by high correlations between the short- and long-form versions of the measure, observed between-group differences in scores for persons with different eye diseases of varying severity, and the moderate-to-high correlations between the NEI VFQ-25 subscales that have the most to do with central vision and measured visual acuity. The reliability and validity of the NEI VFQ-25 are comparable to those of the 51-item NEI VFQ field test version of the survey. This shorter version will be more feasible in settings such as clinical trials where interview length is a critical consideration. In addition, preliminary analyses indicate that the psychometric properties of the NEI VFQ-25 are robust for the eye conditions studied; this suggests that the measure will provide reproducible and valid data when used across multiple conditions of varying severity.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Descemet membrane endothelial keratoplasty (DMEK).

            To describe Descemet membrane endothelial keratoplasty (DMEK) with organ cultured Descemet membrane (DM) in a human cadaver eye model and a patient with Fuchs endothelial dystrophy. In 10 human cadaver eyes and 1 patient eye, a 3.5-mm clear corneal tunnel incision was made. The anterior chamber was filled with air, and the DM was stripped off from the posterior stroma. From organ-cultured donor corneo-scleral rims, 9.0-mm-diameter "DM rolls" were harvested. Each donor DM roll was inserted into a recipient anterior chamber, positioned onto the posterior stroma, and kept in position by completely filling the anterior chamber with air for 30 minutes. In all recipient eyes, the donor DM maintained its position after a 30-minute air-fill of the anterior chamber followed by an air-liquid exchange. In the patient's eye, 1 week after transplantation, best-corrected visual acuity was 1.0 (20/20) with the patient's preoperative refraction, and the endothelial cell density averaged 2350 cells/mm. DMEK may provide quick visual rehabilitation in the treatment of corneal endothelial disorders by transplantation of an organ-cultured DM transplanted through a clear corneal tunnel incision. DMEK may be a highly accessible procedure to corneal surgeons, because donor DM sheets can be prepared from preserved corneo-scleral rims.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue.

              To compare outcomes with 2 donor dissection methods for Descemet's stripping with endothelial keratoplasty (DSEK). Retrospective, comparative, nonrandomized case series. Three hundred thirty consecutive transplants, 114 with manually dissected and 216 with microkeratome-dissected donor tissue. Donor posterior stroma/endothelium was transplanted, after stripping recipient Descemet's membrane/endothelium and dissecting the donor tissue by hand or with a microkeratome. Incidences of donor perforation and donor detachment were compared for all eyes. Visual and refractive outcomes were compared for the first 100 consecutive eyes in each group. Visual recovery was faster with microkeratome-dissected donor tissue, as evidenced by statistically better best spectacle-corrected visual acuity (VA) in that group 1 month after surgery (P = 0.015). Best spectacle-corrected VA was statistically comparable for the 2 groups preoperatively and 3 and 6 months postoperatively. Best spectacle-corrected VA was not correlated significantly with postoperative central corneal thickness (P = 0.25). Corneal thickness was significantly higher in the microkeratome group (690+/-77 mum, compared with 610+/-62 mum after hand dissection; P<0.0001). Mean refractive astigmatism was 1.5 diopters (D) preoperatively and 6 months postoperatively in both groups. Spherical equivalent refraction did not change in the microkeratome group (P = 0.64) but increased by 0.66 D in the hand dissection group (P = 0.0007). Methods designed to remove fluid from the donor/recipient graft interface ultimately reduced the detachment rate to <1% (1 in the last 140 cases). No donor perforations occurred in 216 microkeratome dissections, compared with 5 in 114 hand dissections (P = 0.002). Microkeratome dissection reduced the risk of donor tissue perforation, provided faster visual recovery after DSEK, and did not alter the refractive outcome.
                Bookmark

                Author and article information

                Contributors
                Role: Academic Editor
                Journal
                Medicina (Kaunas)
                medicina
                Medicina
                MDPI
                1010-660X
                1648-9144
                03 February 2021
                February 2021
                : 57
                : 2
                : 133
                Affiliations
                [1 ]Department of Biomedicine, Neurosciences and Advanced Diagnostic, Ophthalmology Section, University of Palermo, 90127 Palermo, Italy; massimo.castellucci@ 123456gmail.com (M.C.); costanza.novara88@ 123456gmail.com (C.N.); giovannicillino@ 123456libero.it (G.C.); vale.failla@ 123456hotmail.it (V.F.); enzabonfiglio@ 123456gmail.com (V.B.); maria.vadala@ 123456unipa.it (M.V.)
                [2 ]Department of Health Promotion, Mother Child Care, Internal Medicine and of Excellence, University of Palermo, 90127 Palermo, Italy; alessandra.casuccio@ 123456unipa.it
                [3 ]Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties (ProMISE), Section of Endocrinology, Diabetology and Metabolism, University of Palermo, 90127 Palermo, Italy; carla.giordano@ 123456unipa.it
                Author notes
                [* ]Correspondence: salvatore.cillino@ 123456unipa.it ; Tel.: +39-0916-553-901; Fax: +39-091-342-770
                Author information
                https://orcid.org/0000-0003-2284-6552
                https://orcid.org/0000-0002-5676-9535
                https://orcid.org/0000-0002-2726-698X
                https://orcid.org/0000-0002-5721-6772
                Article
                medicina-57-00133
                10.3390/medicina57020133
                7913208
                33546152
                c22c4647-082c-4a3b-a97e-c32899f2704f
                © 2021 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 19 January 2021
                : 28 January 2021
                Categories
                Article

                bilateral ultrathin dsaek,bilateral penetrating keratoplasty,visual acuity,contrast sensitivity,higher-order aberrations,quality of life

                Comments

                Comment on this article