40
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Device-Associated Nosocomial Infections in 55 Intensive Care Units of 8 Developing Countries

      Annals of Internal Medicine
      American College of Physicians

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Health care-associated infections from invasive medical devices in the intensive care unit (ICU) are a major threat to patient safety. Most published studies of ICU-acquired infections have come from industrialized western countries. In a Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance (NNIS) System report, the U.S. pooled mean rates of central venous catheter (CVC)-related bloodstream infections, ventilator-associated pneumonia, and catheter-associated urinary tract infections were 4.0 per 1000 CVC days, 5.4 per 1000 mechanical ventilator days, and 3.9 per Foley catheter days, respectively. To ascertain the incidence of device-associated infections in the ICUs of developing countries. Multicenter, prospective cohort surveillance of device-associated infection by using the CDC NNIS System definitions. 55 ICUs of 46 hospitals in Argentina, Brazil, Colombia, India, Mexico, Morocco, Peru, and Turkey that are members of the International Nosocomial Infection Control Consortium (INICC). Rates of device-associated infection per 100 patients and per 1000 device days. During 2002-2005, 21,069 patients who were hospitalized in ICUs for an aggregate 137,740 days acquired 3095 device-associated infections for an overall rate of 14.7% or 22.5 infections per 1000 ICU days. Ventilator-associated pneumonia posed the greatest risk (41% of all device-associated infections or 24.1 cases [range, 10.0 to 52.7 cases] per 1000 ventilator days), followed by CVC-related bloodstream infections (30% of all device-associated infections or 12.5 cases [range, 7.8 to 18.5 cases] per 1000 catheter days) and catheter-associated urinary tract infections (29% of all device-associated infections or 8.9 cases [range, 1.7 to 12.8 cases] per 1000 catheter days). Notably, 84% of Staphylococcus aureus infections were caused by methicillin-resistant strains, 51% of Enterobacteriaceae isolates were resistant to ceftriaxone, and 59% of Pseudomonas aeruginosa isolates were resistant to fluoroquinolones. The crude mortality rate for patients with device-associated infections ranged from 35.2% (for CVC-associated bloodstream infection) to 44.9% (for ventilator-associated pneumonia). These initial data are not adequate to represent any entire country, and likely variations in the efficiency of surveillance and institutional resources may have affected the rates that were detected. Device-associated infections in the ICUs of these developing countries pose greater threats to patient safety than in U.S. ICUs. Active infection control programs that perform surveillance of infection and implement guidelines for prevention can improve patient safety and must become a priority in every country.

          Related collections

          Author and article information

          Journal
          Annals of Internal Medicine
          Ann Intern Med
          American College of Physicians
          0003-4819
          October 17 2006
          October 17 2006
          : 145
          : 8
          : 582
          Article
          10.7326/0003-4819-145-8-200610170-00007
          17043340
          c11378eb-af76-46fd-ba2f-fe2165b6f708
          © 2006
          History

          Comments

          Comment on this article