14
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Can Endoscopic Tympanoplasty Be a Good Alternative to Microscopic Tympanoplasty? A Systematic Review and Meta-Analysis

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Although efficacies and proportions of tympanoplasty performed via endoscopic ear surgery (EES) have gradually introduced, it remains unclear whether total EES is a good alternative to microscopic ear surgery (MES). Herein, we aimed to compare therapeutic effects of EES and MES in patients receiving tympanoplasty or myringoplasty. A search of MEDLINE, PubMed, and Embase databases was conducted to compare the efficacies of EES and MES. Two investigators independently reviewed all studies and extracted data with a standardized form. We assessed risk of bias and calculated pooled odds ratio (OR) estimates with a 95% confidence interval (CI). Thirteen studies (607 EES patients and 678 MES patients) met inclusion criteria for quantitative meta-analysis. In pooled analysis, those who undergo EES have 0.99 times the OR of graft success compared to those with MES (95% CI, 0.84 to 1.16; P=0.894). In qualitative analysis, comparable hearing improvement was observed between the two groups, despite inconsistent audiometric evaluation. The air-bone gaps (ABGs) improved 2.02 dB less in EES than in MES (mean difference of improvements of ABGs, 2.02; 95% CI, –3.84 to –0.20; P=0.029); however, substantial heterogeneity and publication bias limited the integrity of this analysis. Further, EES significantly decreased canalplasty rate, wound complications, and operation time, compared to MES. Moreover, patients receiving EES reported higher cosmetic satisfaction than patients receiving MES. EES can be a good alternative to MES in terms of comparable graft success rate and hearing outcomes in patients receiving tympanoplasty or myringoplasty. Moreover, EES was less invasive, resulting in higher cosmetic satisfaction, reduced morbidity, and shorter operation time. Our results may affect decision-making and outcome prediction in cases of EES; however, confirmation is needed to clarify potential bias.

          Related collections

          Most cited references30

          • Record: found
          • Abstract: found
          • Article: not found

          Endoscopic middle ear surgery.

          One hundred sixty-five middle ear procedures were performed with an endoscope, a camera, and a video monitor instead of the microscope. The endoscope offers the following advantages: 1) it visualizes the whole tympanic membrane and the ear canal without having to manipulate the patient's head or the microscope, 2) it extends the operative field in transcanal procedures into structures usually hidden from the microscope (anterior tympanic perforation, posterior retraction pocket, facial recess, and hypotympanum), and 3) it visualizes structures from multiple angles as opposed to the microscope's single axis along the ear canal. Disadvantages of the endoscope include the one-handed surgical technique, a loss of depth perception, limited magnification, and the need for training. The endoscope holds the greatest promise in tympanoplasty and cholesteatoma surgery and should increase the utilization of transcanal over postauricular procedures.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Systematic review of outcomes following observational and operative endoscopic middle ear surgery.

            Middle ear surgery increasingly employs endoscopes as an adjunct to or replacement for the operative microscope. We provide a systematic review of endoscope applications in middle ear surgery with an emphasis on outcomes, including the need for conversion to microscope, audiometric findings, length of follow-up, as well as disease-specific outcomes.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Comparison of Endoscopic Tympanoplasty to Microscopic Tympanoplasty

              Objectives This study aimed to compare the outcome of endoscopic and microscopic tympanoplasty. Methods This was a retrospective comparative study of 73 patients (35 males and 38 females) who underwent type I tympanoplasty at Samsung Medical Center from April to December 2014. The subjects were classified into two groups; endoscopic tympanoplasty (ET, n=25), microscopic tympanoplasty (MT, n=48). Demographic data, perforation size of tympanic membrane at preoperative state, pure tone audiometric results preoperatively and 3 months postoperatively, operation time, sequential postoperative pain scale (NRS-11), and graft success rate were evaluated. Results The perforation size of the tympanic membrane in ET and MT group was 25.3%±11.7% and 20.1%±11.9%, respectively (P=0.074). Mean operation time of MT (88.9±28.5 minutes) was longer than that of the ET (68.2±22.1 minutes) with a statistical significance (P=0.002). External auditory canal (EAC) width was shorter in the ET group than in the MT group (P=0.011). However, EAC widening was not necessary in the ET group and was performed in 33.3% of patients in the MT group. Graft success rate in the ET and MT group were 100% and 95.8%, respectively; the values were not significantly different (P=0.304). Pre- and postoperative audiometric results including bone and air conduction thresholds and air-bone gap were not significantly different between the groups. In all groups, the postoperative air-bone gap was significantly improved compared to the preoperative air-bone gap. Immediate postoperative pain was similar between the groups. However, pain of 1 day after surgery was significantly less in the ET group. Conclusion With endoscopic system, minimal invasive tympanoplasty can be possible with similar graft success rate and less pain.
                Bookmark

                Author and article information

                Journal
                Clin Exp Otorhinolaryngol
                Clin Exp Otorhinolaryngol
                CEO
                Clinical and Experimental Otorhinolaryngology
                Korean Society of Otorhinolaryngology-Head and Neck Surgery
                1976-8710
                2005-0720
                May 2019
                25 January 2019
                : 12
                : 2
                : 145-155
                Affiliations
                Department of Otorhinolaryngology-Head and Neck Surgery, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea
                Author notes
                Corresponding author: Young Ho Kim Department of Otorhinolaryngology-Head and Neck Surgery, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, 20 Boramae-ro 5-gil, Dongjak-gu, Seoul 07061, Korea Tel: +82-2-870-2442, Fax: +82-2-870-3863 E-mail: yhkiment@ 123456gmail.com
                Author information
                http://orcid.org/0000-0003-3566-8708
                http://orcid.org/0000-0001-7328-5068
                Article
                ceo-2018-01277
                10.21053/ceo.2018.01277
                6453785
                30674106
                b5edf626-9f4e-4749-a6aa-99946d94ed81
                Copyright © 2019 by Korean Society of Otorhinolaryngology-Head and Neck Surgery

                This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 1 September 2018
                : 29 November 2018
                : 04 December 2018
                Categories
                Review

                Otolaryngology
                endoscopes,tympanoplasty,myringoplasty,review
                Otolaryngology
                endoscopes, tympanoplasty, myringoplasty, review