      Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Procedures involving phlebotomy are critical for obtaining diagnostic blood specimens and represent a well known and recognized problem, probably among the most important issues in laboratory medicine. The aim of this report is to show spurious hyperkalemia and hypocalcemia due to inadequate phlebotomy procedure. The diagnostic blood specimens were collected from a male outpatient 45 years old, with no clinical complaints. The tubes drawing order were as follows: i) clot activator and gel separator (serum vacuum tube), ii) K 3EDTA, iii) a needleless blood gas dedicated-syringe with 80 I.U. lithium heparin, directly connected to the vacuum tube holder system. The laboratory testing results from serum vacuum tube and dedicated syringe were 4.8 and 8.5 mmol/L for potassium, 2.36 and 1.48 mmol/L for total calcium, respectively. Moreover 0.15 mmol/L of free calcium was observed in dedicated syringe. A new blood collection was performed without K 3EDTA tube. Different results were found for potassium (4.7 and 4.5 mmol/L) and total calcium (2.37 and 2.38 mmol/L) from serum vacuum tube and dedicated syringe, respectively. Also free calcium showed different concentration (1.21 mmol/L) in this new sample when compared with the first blood specimen. Based on this case we do not encourage the laboratory managers training the phlebotomists to insert the dedicated syringes in needle-holder system at the end of all vacuum tubes. To avoid double vein puncture the dedicated syringe for free calcium determination should be inserted immediately after serum tubes before EDTA vacuum tubes.

          Related collections

          Most cited references29

          • Record: found
          • Abstract: found
          • Article: not found

          Quality standards for sample collection in coagulation testing.

          Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The reference change value: a proposal to interpret laboratory reports in serial testing based on biological variation.

            A proposal to calculate and use the reference change value (RCV) as an objective guide for interpreting the numerical results obtained in clinical laboratory serial testing is introduced in this study. A database showing the results of a compilation of 191 publications on biological variation and including information on a number of analytes provided the standardized criterion based on biology for calculating the RCVs. For each of the 261 analytes included in the study, the RCV was determined using Harris's formula, replacing analytical imprecision with the desirable specification of analytical quality based on half the within-subject biological variation at 95% probability levels. The result is a guide for a common criterion to identify clinically significant changes in serial results. The RCV concept is an approach that can be offered by laboratories to assess changes in serial results. The RCV data in this study are presented as a point of departure for a widely applicable objective guide to interpret changes in serial results.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.

              The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near-infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in patients with difficult or small veins, such as children. This study was aimed to evaluate whether a transillumination device can advantageously replace the use of the tourniquet during the procedure for collection of blood specimens for RHT and thereby eliminating the discomfort and risk of spurious results caused by excessive or prolonged venous stasis. Two hundred and fifty volunteers were divided into five groups (G1, G2, G3, G4 and G5) to compare the results of RHT between blood sample collected with transilluminator device (left arm) and with tourniquet application (right arm) for 30 s(G1), 60 s(G2), 90 s(G3), 120 s(G4) and 180 s(G5). No significant increases were observed in any of the haematological parameters tested in G1 when compared with blood collected by the transilluminator device. From G2 to G5, significant increases were observed for the platelet count, red blood cell count, haemoglobin, haematocrit, white blood cell count, neutrophils, monocytes and eosinophils. From G3-G5, further increases were observed for lymphocytes. Clinically significant variations were, however, observed for basophils in G2; red blood cell count, haemoglobin, haematocrit and basophils in G3 and eosinophils in G3 only. As such, considering that inappropriate use of the tourniquet is commonplace, we conclude that transillumination devices can represent a suitable tool to eliminate the venous stasis and to improve the quality of phlebotomy procedures. © 2011 Blackwell Publishing Ltd.
                Bookmark

                Author and article information

                Journal
                Biochem Med (Zagreb)
                Biochem Med (Zagreb)
                Biochemia Medica
                Biochemia Medica
                Croatian Society of Medical Biochemistry and Laboratory Medicine
                1330-0962
                1846-7482
                15 June 2013
                June 2013
                : 23
                : 2
                : 218-223
                Affiliations
                [1 ]Laboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Verona, Italy
                [2 ]Post-Graduate Program of Pharmaceutical Sciences, Department of Medical Pathology Federal University of Parana, Curitiba, Parana, Brazil
                [3 ]MERCOSUL: Sector Committee of Clinical Analyses and in Vitro Diagnostics – CSM 20, Rio de Janeiro, Brazil
                [4 ]Brazilian Society of Clinical Analyses on Sao Paulo State, Brazil
                [5 ]Clinical Chemistry and Hematology Laboratory, Department of Pathology and Laboratory Medicine, Academic Hospital of Parma, Parma, Italy
                Author notes
                [* ]Corresponding author: dr.g.lima.oliveira@ 123456gmail.com
                Article
                biochem_med-23-2-218-11
                10.11613/BM.2013.026
                3900060
                23894868
                b501fd9f-1a12-4737-819b-ae895fa01e76
                ©Copyright by Croatian Society of Medical Biochemistry and Laboratory Medicine

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 13 February 2013
                : 01 May 2013
                Categories
                Case Report

                clinical laboratory techniques,preanalytical phase,laboratory variability,blood specimen collection,edta contamination carryover

                Comments

                Comment on this article