To evaluate the efficacy of silicone sheet as a new type of barrier for preventing adhesion reformation following hysteroscopic adhesiolysis of intrauterine adhesions (IUAs).
Hysteroscopic adhesiolysis was performed for 36 patients with IUAs. The adhesion reformation rate was retrospectively compared between 26 patients treated with silicone sheet (group 1) and 10 patients treated with an intrauterine device wrapped in oxidized regenerated cellulose as a barrier (group 2). For patients in group 1, a 1‐mm‐thick silicone sheet was cut to fit the size and shape of the individual uterine cavity as a personalized barrier.
The size and shape of each silicone sheet used for patients in group 1 differed significantly. The adhesion reformation rate was significantly lower in group 1 (4/26, 15.4%) than in group 2 (4/10, 40.0%; P = 0.03), although the pregnancy rate (14/20, 70.0% vs. 5/10, 50.0%; P = 0.28) and miscarriage rate (2/14, 14.3% vs. 1/5, 20.0%; P = 0.72) were not significantly different.
See how this article has been cited at scite.ai